arXiv ScienceSearch

arXiv subjects

Cathy Speed

Publications and source records attributed to Cathy Speed.

7 recordsLinked to original sources

Quantifying Cardiovascular-Kidney-Metabolic(CKM) Health Age Using Wearables and lab Biomarkers

Cardiovascular-Kidney-Metabolic (CKM) syndrome represents a growing public health crisis, yet its subclinical heterogeneity remains underexplored. Early detection of physiological deviation is critical for preventing irreversible organ damage. Here, we characterize the prevalence and interplay of CKM impairment in a US cohort (N=819) by integrating continuous wearable data with clinical biomarkers. We assessed cardiovascular, kidney via clinical biomarkers, namely Chol/HDL, eGFR, as well as metabolic health risk through Homeostatic Model Assessment of Insulin Resistance (HOMA-IR). We show that while metabolic and cardiovascular disruptions are significantly associated (r=0.26, $p<0.001$), early-stage kidney impairment manifests independently. Utilizing a normalized deviance score, we identified significant health impairments in 29.0% of the cohort. Cardiovascular deviation was the most prevalent singular phenotype (13.3%), followed by metabolic (9.1%) and renal (6.25%) deviations, with dual metabolic-cardiovascular impairment occurring in only 2.2% of participants. These findings suggest that high system-specific deviance may serve as an indicator for accelerated physiological aging within the respective organ system. Furthermore, Step count, Active Zone Minutes, and resting heart rate were identified as the key wearable predictors of cardiovascular and metabolic decline. Leveraging these and CKM metrics, we developed a Health Age model that tracks physiological health, aligning with established clinical standards (Metabolic syndrome severity and modified AHA Life's Essential 8) and user-reported overall health. These findings underscore the necessity of a multi-system subtyping approach, demonstrating that wearable-derived phenotypes can facilitate the early, targeted interventions required to manage the complex landscape of CKM syndrome.

q-bio.QM

Beyond BMI: Smartphone Body Composition Phenotyping for Cardiometabolic Risk Assessment

Body Mass Index (BMI) is a widely accessible but imprecise proxy of cardiometabolic health. While assessing true body composition is superior, gold-standard methods like Dual-Energy X-ray Absorptiometry (DXA) are not scalable. We address this gap by developing and validating "PhotoScan," a method to estimate body composition from smartphone imagery. We pretrained a deep learning model on UK Biobank participants (N=35,323) and fine-tuned on a newly recruited clinical cohort (PhotoBIA cohort, N=677) with diverse ethnicity, age, and body fat distribution, achieving high accuracy against DXA for total body fat percentage (BF%, MAE = 2.15%), Android-to-Gynoid fat ratio (A/G, MAE = 0.11), and visceral-to-subcutaneous fat area ratio (V/S, MAE = 0.09). Generalizability of the model was demonstrated on an independent metabolic health study cohort (MetabolicMosaic cohort, N=132 participants), achieving MAEs of 2.13% for BF%, 0.09 for A/G, and 0.09 for V/S. We then evaluated the clinical utility of these metrics in the MetabolicMosaic cohort by predicting insulin resistance (IR). Adding PhotoScan-derived body composition metrics to baseline demographics model (Age, Sex, BMI) significantly improved insulin resistance classification (Area Under the Receiver Operating Characteristic Curve "AUROC" 76.0% vs 69.2%, DeLong test p=0.002, Net Reclassification Index "NRI" 0.593). Crucially, this accessible smartphone method achieved performance nearly equivalent to adding clinical-grade DXA data to baseline demographics model (AUROC 77.3% vs 69.2%, DeLong test p=0.004, NRI 0.748). These findings demonstrate that smartphone-based phenotyping captures clinically meaningful risk signals missed by BMI and anthropometrics, offering a scalable alternative to DXA for cardiometabolic risk stratification.

q-bio.QM

Adaptive Cardio Load Targets for Improving Fitness and Performance

Cardio Load, introduced by Google in 2024, is a measure of cardiovascular work (also known as training load) resulting from all the user's activities across the day. It is based on heart rate reserve and captures both activity intensity and duration. Thanks to feedback from users and internal research, we introduce adaptive and personalized targets which will be set weekly. This feature will be available in the Public Preview of the Fitbit app after September 2025. This white paper provides a comprehensive overview of Cardio Load (CL) and how weekly CL targets are established, with examples shown to illustrate the effect of varying CL on the weekly target. We compare Cardio Load and Active Zone Minutes (AZMs), highlighting their distinct purposes, i.e. AZMs for health guidelines and CL for performance measurement. We highlight that CL is accumulated both during active workouts and incidental daily activities, so users are able top-up their CL score with small bouts of activity across the day.

cs.HC

The Human-AI Hybrid Delphi Model: A Structured Framework for Context-Rich, Expert Consensus in Complex Domains

Expert consensus plays a critical role in domains where evidence is complex, conflicting, or insufficient for direct prescription. Traditional methods, such as Delphi studies, consensus conferences, and systematic guideline synthesis, offer structure but face limitations including high panel burden, interpretive oversimplification, and suppression of conditional nuance. These challenges are now exacerbated by information overload, fragmentation of the evidence base, and increasing reliance on publicly available sources that lack expert filtering. This study introduces and evaluates a Human-AI Hybrid Delphi (HAH-Delphi) framework designed to augment expert consensus development by integrating a generative AI model (Gemini 2.5 Pro), small panels of senior human experts, and structured facilitation. The HAH-Delphi was tested in three phases: retrospective replication, prospective comparison, and applied deployment in two applied domains (endurance training and resistance and mixed cardio/strength training). The AI replicated 95% of published expert consensus conclusions in Phase I and showed 95% directional agreement with senior human experts in Phase II, though it lacked experiential and pragmatic nuance. In Phase III, compact panels of six senior experts achieved >90% consensus coverage and reached thematic saturation before the final participant. The AI provided consistent, literature-grounded scaffolding that supported divergence resolution and accelerated saturation. The HAH-Delphi framework offers a flexible, scalable approach for generating high-quality, context-sensitive consensus. Its successful application across health, coaching, and performance science confirms its methodological robustness and supports its use as a foundation for generating conditional, personalised guidance and published consensus frameworks at scale.

cs.CL

Insulin Resistance Prediction From Wearables and Routine Blood Biomarkers

Insulin resistance, a precursor to type 2 diabetes, is characterized by impaired insulin action in tissues. Current methods for measuring insulin resistance, while effective, are expensive, inaccessible, not widely available and hinder opportunities for early intervention. In this study, we remotely recruited the largest dataset to date across the US to study insulin resistance (N=1,165 participants, with median BMI=28 kg/m2, age=45 years, HbA1c=5.4%), incorporating wearable device time series data and blood biomarkers, including the ground-truth measure of insulin resistance, homeostatic model assessment for insulin resistance (HOMA-IR). We developed deep neural network models to predict insulin resistance based on readily available digital and blood biomarkers. Our results show that our models can predict insulin resistance by combining both wearable data and readily available blood biomarkers better than either of the two data sources separately (R2=0.5, auROC=0.80, Sensitivity=76%, and specificity 84%). The model showed 93% sensitivity and 95% adjusted specificity in obese and sedentary participants, a subpopulation most vulnerable to developing type 2 diabetes and who could benefit most from early intervention. Rigorous evaluation of model performance, including interpretability, and robustness, facilitates generalizability across larger cohorts, which is demonstrated by reproducing the prediction performance on an independent validation cohort (N=72 participants). Additionally, we demonstrated how the predicted insulin resistance can be integrated into a large language model agent to help understand and contextualize HOMA-IR values, facilitating interpretation and safe personalized recommendations. This work offers the potential for early detection of people at risk of type 2 diabetes and thereby facilitate earlier implementation of preventative strategies.

cs.LG

A Scalable Framework for Evaluating Health Language Models

Large language models (LLMs) have emerged as powerful tools for analyzing complex datasets. Recent studies demonstrate their potential to generate useful, personalized responses when provided with patient-specific health information that encompasses lifestyle, biomarkers, and context. As LLM-driven health applications are increasingly adopted, rigorous and efficient one-sided evaluation methodologies are crucial to ensure response quality across multiple dimensions, including accuracy, personalization and safety. Current evaluation practices for open-ended text responses heavily rely on human experts. This approach introduces human factors and is often cost-prohibitive, labor-intensive, and hinders scalability, especially in complex domains like healthcare where response assessment necessitates domain expertise and considers multifaceted patient data. In this work, we introduce Adaptive Precise Boolean rubrics: an evaluation framework that streamlines human and automated evaluation of open-ended questions by identifying gaps in model responses using a minimal set of targeted rubrics questions. Our approach is based on recent work in more general evaluation settings that contrasts a smaller set of complex evaluation targets with a larger set of more precise, granular targets answerable with simple boolean responses. We validate this approach in metabolic health, a domain encompassing diabetes, cardiovascular disease, and obesity. Our results demonstrate that Adaptive Precise Boolean rubrics yield higher inter-rater agreement among expert and non-expert human evaluators, and in automated assessments, compared to traditional Likert scales, while requiring approximately half the evaluation time of Likert-based methods. This enhanced efficiency, particularly in automated evaluation and non-expert contributions, paves the way for more extensive and cost-effective evaluation of LLMs in health.

cs.AI

Towards a Personal Health Large Language Model

In health, most large language model (LLM) research has focused on clinical tasks. However, mobile and wearable devices, which are rarely integrated into such tasks, provide rich, longitudinal data for personal health monitoring. Here we present Personal Health Large Language Model (PH-LLM), fine-tuned from Gemini for understanding and reasoning over numerical time-series personal health data. We created and curated three datasets that test 1) production of personalized insights and recommendations from sleep patterns, physical activity, and physiological responses, 2) expert domain knowledge, and 3) prediction of self-reported sleep outcomes. For the first task we designed 857 case studies in collaboration with domain experts to assess real-world scenarios in sleep and fitness. Through comprehensive evaluation of domain-specific rubrics, we observed that Gemini Ultra 1.0 and PH-LLM are not statistically different from expert performance in fitness and, while experts remain superior for sleep, fine-tuning PH-LLM provided significant improvements in using relevant domain knowledge and personalizing information for sleep insights. We evaluated PH-LLM domain knowledge using multiple choice sleep medicine and fitness examinations. PH-LLM achieved 79% on sleep and 88% on fitness, exceeding average scores from a sample of human experts. Finally, we trained PH-LLM to predict self-reported sleep quality outcomes from textual and multimodal encoding representations of wearable data, and demonstrate that multimodal encoding is required to match performance of specialized discriminative models. Although further development and evaluation are necessary in the safety-critical personal health domain, these results demonstrate both the broad knowledge and capabilities of Gemini models and the benefit of contextualizing physiological data for personal health applications as done with PH-LLM.

cs.AI