arXiv Science⌕ Search

arXiv subjects

Canhua Xu

Publications and source records attributed to Canhua Xu.

2 recordsLinked to original sources

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

cs.AR↗

Multidimensional Physiology-Inspired Enhanced Vital Sign Monitoring Using MIMO mmWave Bio-radar

With the intensiffcation of population aging and increasing burden of chronic diseases, the demand for vital signs monitoring is becoming increasingly urgent. A key challenge facing current non-contact detection technologies using millimeter wave (mmWave) radar is the low efffciency of multi-channel signal fusion in array radar systems based on equal weighting. To address this challenge, this paper proposes a vital sign enhancement detection method for multiple input and multiple output (MIMO) bio-radar, driven by multidimensional physiological characteristics, which overcomes traditional limitations through a two-stage fusion strategy. Stage 1: Enhanced Vital Sign Detection Using Single-Channel Signals Based on Physiological Characteristics. First, a chest wall multi-scattering point model is constructed. For single channel time-distance two-dimensional echo signals, effective range bins are selected based on the respiratory/cardiac physiological frequency band energy ratio, and the signal-to-noise ratio (SNR) of respiration/heart signals is enhanced using phase-aligned maximal ratio combining (MRC). Stage 2: Multi-Channel Fusion Based on Organ Radiation Spatial Distribution Characteristics. The spatial radiation characteristics of cardiopulmonary organs are introduced for the ffrst time as the theoretical foundation for SNR-based channel screening, channel attribute identiffcation, and multi-channel weighted fusion. Then, we propose a template matching method to extract respiratory rate (RR) and heart rate (HR) by adopting physical models of respiration and cardiac activities. The experimental results demonstrate the existence of the spatial distribution characteristics of organ radiation. In addition, we analyzed the impact of distance and state on the algorithm from these two aspects.

eess.SP↗