Convergence on the Proton Drip-Line in Thulium

Direct observation of proton emission for very small Q-values is often unfeasible due to the long partial half-lives of the proton emission channel associated with tunneling through the Coulomb barrier. Therefore, proton emitters with very small decay energies may require the masses of both parent and daughter nuclei in order to establish them as proton unbound. Nuclear mass models have been used to predict the proton drip-line of the thulium (Tm) isotopic chain ($Z=69$), but until now the proton separation energy has not been experimentally tested. Mass measurements were performed using a Multiple Reflection Time-Of-Flight Mass Spectrometer (MR-TOF-MS) at TRIUMF's TITAN facility to conclusively map the limit of proton-bound Tm. The masses of neutron-deficient, $^{149}$Tm and $^{150}$Tm, combined with measurements of $^{149m,g}$Er (which were found to deviate from literature by $\approx$150 keV), provide the first experimental confirmation that $^{149}$Tm is the first proton-unbound nuclide in the Tm chain. Our measurements also enable the strength of the $N=82$ neutron shell gap to be determined at the Tm proton drip-line, providing evidence supporting its continued existence.

nucl-ex

Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons

We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.

physics.atom-ph

A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios

The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, $-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}}$ = $1.000\,000\,000\,003 (16)$, is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of $1.96\cdot10^{-27}\,$GeV (C$.$L$.$ 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP$_\text{cc}$) for antimatter to a level of $|\alpha_{g}-1| < 1.8 \cdot 10^{-7}$, and enables the first differential test of the WEP$_\text{cc}$ using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEP$_\text{cc}$-violating coefficient to $|\alpha_{g,D}-1|<0.030$.

physics.atom-ph

Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature

We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.

physics.atom-ph

Ultra thin polymer foil cryogenic window for antiproton deceleration and storage

We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $\mu$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons through the window, we tested the degrading properties of different aluminium coated PET foils of thicknesses between 900nm and 2160nm, concluding that 1760nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature, and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of 7 holes with 1 mm diameter and will transmit up to 2.5% of the injected 100keV antiproton beam delivered by the AD/ELENA-facility of CERN.

physics.ins-det

BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies

Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.

physics.ins-det

Testing CPT Invariance by High-Precision Comparisons of Fundamental Properties of Protons and Antiprotons at BASE

The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts in a trillion. In this contribution, we give an overview of the measurement campaign, and detail how its results are used to constrain nine spin-independent coefficients of the Standard-Model Extension in the proton and electron sector.

hep-ex

Collision-Induced Dissociation at TRIUMF's Ion Trap for Atomic and Nuclear science

The performance of high-precision mass spectrometry of radioactive isotopes can often be hindered by large amounts of contamination, including molecular species, stemming from the production of the radioactive beam. In this paper, we report on the development of Collision-Induced Dissociation (CID) as a means of background reduction for experiments at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This study was conducted to characterize the quality and purity of radioactive ion beams and the reduction of molecular contaminants to allow for mass measurements of radioactive isotopes to be done further from nuclear stability. This is the first demonstration of CID at an ISOL-type radioactive ion beam facility, and it is shown that molecular contamination can be reduced up to an order of magnitude.

nucl-ex

Sympathetic cooling schemes for separately trapped ions coupled via image currents

Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and find, based on analytical calculations and numerical simulations, that two of them are capable of achieving proton temperatures of about 10 mK with cooling times on the order of 10 s. In contrast, established methods such as feedback-enhanced resistive cooling with image-current detectors are limited to about 1 K in 100 s. Since the studied techniques are applicable to any trapped charged particle and allow spatial separation between the target ion and the cooling species, they enable a variety of precision measurements based on trapped charged particles to be performed at improved sampling rates and with reduced systematic uncertainties.

physics.atom-ph

Sympathetic cooling of a trapped proton mediated by an LC circuit

Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic cooling has required close-range Coulomb interactions, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps, extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be+ ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image-current interactions, it can be easily applied to an experiment with antiprotons, facilitating improved precision in matter-antimatter comparisons and dark matter searches.

physics.atom-ph

Mass Measurements of Neutron-Rich Gallium Isotopes Refine Production of Nuclei of the First r-Process Abundance Peak in Neutron Star Merger Calculations

We report mass measurements of neutron-rich Ga isotopes $^{80-85}$Ga with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The measurements determine the masses of $^{80-83}$Ga in good agreement with previous measurements. The masses of $^{84}$Ga and $^{85}$Ga were measured for the first time. Uncertainties between $25-48$ keV were reached. The new mass values reduce the nuclear uncertainties associated with the production of A $\approx$ 84 isotopes by the \emph{r}-process for astrophysical conditions that might be consistent with a binary neutron star (BNS) merger producing a blue kilonova. Our nucleosynthesis simulations confirm that BNS merger may contribute to the first abundance peak under moderate neutron-rich conditions with electron fractions $Y_e=0.35-0.38$.

nucl-ex

Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes

A precision mass investigation of the neutron-rich titanium isotopes $^{51-55}$Ti was performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the $N=32$ shell closure and the overall uncertainties of the $^{52-55}$Ti mass values were significantly reduced. Our results confirm the existence of a weak shell effect at $N=32$, establishing the abrupt onset of this shell closure. Our data were compared with state-of-the-art \textit{ab-initio} shell model calculations which, despite very successfully describing where the $N=32$ shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements also represent the first scientific results of TITAN using the newly commissioned Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS), substantiated by independent measurements from TITAN's Penning trap mass spectrometer.

nucl-ex

The space of solsolitons in low dimensions

Up to now, the only known examples of homogeneous nontrivial Ricci soliton metrics are the so called solsolitons, i.e. certain left invariant metrics on simple connected solvable Lie groups. In this paper, we describe the moduli space of solsolitons of dimension less or equal than 6, up to isomorphism and scaling. We start with the already known classification of nilsolitons and, following the characterization given by Lauret, we describe the subspace of solsolitons associated to a given nilsoliton, as the quotient of a Grassmanian by a finite group.

math.DG

The IAU 2000 resolutions for astrometry, celestial mechanics and metrology in the relativistic framework: explanatory supplement

This paper discusses the IAU Resolutions B1.3, B1.4, B1.5 and B1.9 (2000) that were adopted during the 24th General Assembly in Manchester, 2000 and provides details and explanations for these Resolutions. It is explained why they present significant progress over the corresponding IAU 1991 Resolutions and why they are necessary in the light of present accuracies in astrometry, celestial mechanics and metrology. In fact most of these Resolutions are consistent with astronomical models and software already in use. The metric tensors and gravitational potentials of both the Barycentric Celestial Reference System and Geocentric Celestial Reference System are defined and discussed. The necessity and relevance of the two celestial reference systems are explained. The transformations of coordinates and gravitational potentials are discussed. Potential coefficients parameterizing the post-Newtonian gravitational potentials are expounded. Simplified versions of the time transformations suitable for modern clock accuracies are elucidated. Various approximations used in the Resolutions are explicated and justified. Some models (e.g. for higher spin moments) that serve the purpose for estimating orders of magnitude have actually never been published before.

astro-ph