arXiv ScienceSearch

arXiv subjects

C. Rethmeier

Publications and source records attributed to C. Rethmeier.

17 recordsLinked to original sources

Measurement of the muon flux at SNOLAB using the DEAP-3600 experiment

A direct measurement of the muon flux at SNOLAB is performed using the DEAP-3600 experiment, located 2 km underground at SNOLAB near Sudbury, Canada. Primarily designed for the direct detection of weakly interacting massive particles (WIMPs), a dark matter candidate, DEAP-3600 consists of an inner spherical acrylic vessel containing a liquid argon target; this vessel is enclosed within a steel shell which is submerged in an instrumented water tank, serving as a muon veto for the dark matter search. The muon flux measurement is performed using a cut-and-count analysis of events observed in the muon veto detector and of events which are coincident between the muon veto and the liquid argon target. The requirement that muons traverse both the water and liquid argon minimizes instrumental backgrounds and systematic uncertainties. Using data collected from November 2016 to March 2020, the muon flux is measured by this coincidence analysis to be $(3.71 \pm 0.25_{\textrm{stat}} \pm 0.09_{\textrm{sys}}) \times 10^{-10}\, \mu/$cm$^2$/s. The standalone measurement using muon veto data only is compatible within uncertainties. Both measurements agree with the previous result by the SNO experiment and with simulations carried out using the MUTE software. These results provide an important benchmark for future rare-event searches at the SNOLAB facility.

hep-ex

First evidence of neutrino absorption on argon using $^{8}$B solar neutrinos in DEAP-3600

We report experimental evidence for electron neutrino charged-current interactions (neutrino absorption, CC $\nu_e$) from $^{8}$B solar neutrinos on $^{40}$Ar using an exposure of ($7.29 \pm 0.05$) tonne$\cdot$years in the DEAP-3600 detector. A region of interest (ROI) of 10.5-13.0 MeV reconstructed energy calibrated on single-peak events, corresponding to incident neutrino energy in 12.0-14.5 MeV, is used for this measurement. We observe 5 single-peak and 1 double-peak neutrino-like events consistent with the $^{8}$B solar neutrino energy spectrum in the ROI after correcting for nonlinearities in the detector response at high energies. With an expected background of $0.48~^{+0.16}_{-0.15}$ events, the data correspond to a significance of $4.0\,\sigma$ with respect to the background-only hypothesis. We report an energy-averaged cross section of $(4.0~^{+2.0}_{-1.6}~\mathrm{(stat)}~^{+0.8}_{-0.7}~\mathrm{(sys)})\times 10^{-41}\,\mathrm{cm}^2$ in the ROI for the CC $\nu_{e}$ signal, a factor $(2.4~^{+1.3}_{-1.0})$ higher than predicted by Bhattacharya, Goodman and Garc\'ia (2009).

hep-ex

Dark Matter Search with the DEAP-3600 Detector using the Profile Likelihood Ratio Method

We present here a search for WIMP dark matter using 790.8 live-days of data collected with 3269 kg of liquid argon (1266 kg fiducial) by the DEAP-3600 detector at SNOLAB, using the Profile Likelihood Ratio method. The likelihood model is based on three parameters: estimated energy, pulse-shape discrimination parameter, and reconstructed position within the detector. Using this method, the expected signal sensitivity of DEAP-3600 benefits from an increased fiducial volume and improved event selection acceptance. Alpha-decays from a small number of dust particulates circulating within the liquid argon target are the dominant source of background events and limit the sensitivity of this search. This result provides improved exclusion upper limits on the WIMP-nucleon spin-independent cross section on liquid argon for WIMP masses between 20 GeV/$c^{2}$ and 100 GeV/$c^{2}$. At 100 GeV/$c^{2}$ the observed limit is 3.4 $\times$ 10$^{-45}$ cm$^2$ at 90% confidence level.

hep-ex

Absorption of Fermionic Dark Matter in the PICO-60 C$_{3}$F$_{8}$ Bubble Chamber

Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a non-relativistic effective field theory framework. An analysis of data from the PICO-60 C$_{3}$F$_{8}$ bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/$\textit{c}^2$ and establishes the first limits on spin-dependent absorptive interactions. These results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.

hep-ex

Direct Measurement of the $^{39}$Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector

The half-life of $^{39}$Ar is measured using the DEAP-3600 detector located 2 km underground at SNOLAB. Between 2016 and 2020, DEAP-3600 used a target mass of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere in a direct-detection dark matter search. Such an argon mass also enables direct measurements of argon isotope properties. The decay of $^{39}$Ar in DEAP-3600 is the dominant source of triggers by two orders of magnitude, ensuring high statistics and making DEAP-3600 well-suited for measuring this isotope's half-life. Use of the pulse-shape discrimination technique in DEAP-3600 allows powerful discrimination between nuclear recoils and electron recoils, resulting in the selection of a clean sample of $^{39}$Ar decays. Observing over a period of 3.4 years, the $^{39}$Ar half-life is measured to be $(302 \pm 8_{\rm stat} \pm 6_{\rm sys})$ years. This new direct measurement suggests that the half-life of $^{39}$Ar is significantly longer than the accepted value, with potential implications for measurements using this isotope's half-life as input.

nucl-ex

Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $\alpha$-Particles in Liquid Argon using DEAP-3600 Data

The knowledge of scintillation quenching of $\alpha$-particles plays a paramount role in understanding $\alpha$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.

physics.ins-det

Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.

astro-ph.CO

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

physics.ins-det

Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

astro-ph.CO

First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector

Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.

astro-ph.CO

Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector

DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effective Field Theory framework, and further examines how various possible substructures in the local dark matter halo may affect these constraints. Such substructures are hinted at by kinematic structures in the local stellar distribution observed by the Gaia satellite and other recent astronomical surveys. These include the Gaia Sausage (or Enceladus), as well as a number of distinct streams identified in recent studies. Limits are presented for the coupling strength of the effective contact interaction operators $\mathcal{O}_1$, $\mathcal{O}_3$, $\mathcal{O}_5$, $\mathcal{O}_8$, and $\mathcal{O}_{11}$, considering isoscalar, isovector, and xenonphobic scenarios, as well as the specific operators corresponding to millicharge, magnetic dipole, electric dipole, and anapole interactions. The effects of halo substructures on each of these operators are explored as well, showing that the $\mathcal{O}_5$ and $\mathcal{O}_8$ operators are particularly sensitive to the velocity distribution, even at dark matter masses above 100 GeV/$c^2$.

astro-ph.CO

The liquid-argon scintillation pulseshape in DEAP-3600

DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD. The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response. TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.

physics.ins-det

Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector

The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $\beta$ and $\gamma$-rays originating from internal and external radioactivity in the detector material. A background model of the ER interactions in DEAP-3600 was developed and is described in this work. The model is based on several components which are expected from radioisotopes in the LAr, from ex-situ material assay measurements, and from dedicated independent in-situ analyses. This prior information is used in a Bayesian fit of the ER components to a 247.2 d dataset to model the radioactivity in the surrounding detector materials. While excellent discrimination between ERs and NRs is reached with pulse shape discrimination, utilizing the large difference between fast and slow components of LAr scintillation light, detailed knowledge of the ER background and activity of detector components, sets valuable constraints on other key types of backgrounds in the detector: neutrons and alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is determined by measuring the daughter decay of $^{42}$K. This cosmogenically activated trace isotope is a relevant background at higher energies for other rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND. The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm 5.9$ $\mu$Bq/kg of argon.

nucl-ex

Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB

DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.

astro-ph.CO

Design and Construction of the DEAP-3600 Dark Matter Detector

The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector.

astro-ph.IM

First results from the DEAP-3600 dark matter search with argon at SNOLAB

This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 tonne-days) of data taken with the nearly full detector during the initial filling phase demonstrates the detector performance and the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage $<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate signal events are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100 GeV/c$^2$ WIMP mass (90% C.L.).

astro-ph.CO

In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.

physics.ins-det