arXiv ScienceSearch

arXiv subjects

C. Quick

Publications and source records attributed to C. Quick.

8 recordsLinked to original sources

Offline Commissioning of the St. Benedict Gas Catcher

Precision measurements of $\beta$ decay transitions offer a promising channel through which the Standard Model (SM) can be probed. There is currently an ongoing effort to increase the precision on measurements of $\mathcal{F}t$-values for superallowed $\beta$ decay transitions between mirror nuclides. These allow for a determination of $V_{ud}$ which is complementary to that obtained from pure Fermi $0^+ \rightarrow 0^+$ transitions. The Superallowed Transition BEta-NEutrino Decay Ion Coincidence Trap (St. Benedict), under construction at the Nuclear Science Laboratory (NSL) at the University of Notre Dame, seeks to measure the Fermi-to-Gamow-Teller mixing ratio for transitions between mirror nuclei in order to expand the list of nuclides from which $V_{ud}$ can be extracted. Production and selection of the species of interest will be done in-flight, using the \textit{TwinSol} magnetic separator system. The first element of St. Benedict will be a large volume gas catcher which will thermalize radioactive ion beams for low energy delivery to the rest of the system. Offline commissioning of this gas catcher has been completed using an internal potassium source, and the device demonstrated a transport efficiency upwards of 95\% for pressures of 66 mbar and lower.

physics.ins-det

The N=126 Factory: A New Multi-Nucleon Transfer Reaction Facility

Multi-nucleon transfer (MNT) reactions between two heavy ions offer an effective method of producing heavy, neutron-rich nuclei that cannot currently be accessed efficiently using traditional production techniques. These nuclei are important for understanding many astrophysical phenomena, such as the formation of the r-process $A\sim 195$ abundance peak. The N=126 Factory currently commissioning at Argonne National Laboratory's ATLAS facility will make use of these reactions to allow for the study of these nuclei. To convert MNT reaction products, which have a wide angular distribution, into a collimated, bunched beam suitable for experiments, a series of apparatus will be used. These start with a large-volume gas catcher for stopping the reaction products, which are then extracted through a radiofrequency quadrupole ion guide, undergo preliminary dipole magnetic separation, cooling and bunching in a Cooler-Buncher, and final separation using a multi-reflection time-of-flight mass separator, before final delivery to experimental systems.

physics.acc-ph

Precision Mass Measurements of \textsuperscript{130}Te, \textsuperscript{130}Sn, and Their Impact on Models for R-Process Nucleosynthesis

The astrophysical rapid neutron capture nucleosynthesis process (r-process) remains an active area of research due to the fact that it occurs in extreme conditions and involves reactions with exotic nuclei that are difficult to study experimentally. For the first time using the Phase-Imaging Ion Cyclotron Resonance (PI-ICR) technique, we measured the mass excesses of \textsuperscript{130}Te, \textsuperscript{130}Sn, and \textsuperscript{130}Sn\textsuperscript{m} with the Canadian Penning Trap (CPT). Our results show good agreement with previous Penning trap values obtained using the Time-of-Flight Ion Cyclotron Resonance (TOF-ICR) and the Fourier Transform Ion Cyclotron Resonance (FT-ICR) techniques, while being twice as precise for \textsuperscript{130}Sn. These new mass excesses were added to a SkyNet network calculation to determine their impact on r-process abundances and to find the best astrophysical conditions to reproduce the Solar System r-process abundance pattern. Finally, by treating lighter and heavier elements separately, we assess the relative frequency of events producing elements in a cold versus a hot r-process scenario.

nucl-ex

Precise Mass Measurement of the $^{149}$La-$^{149}$Ce-$^{149}$Pr isobaric chain

Penning trap mass measurements of $^{149}$La, $^{149}$Ce, and $^{149}$Pr were performed with the Canadian Penning Trap (CPT) at the CARIBU facility of Argonne National Laboratory using the phase-imaging ion-cyclotron-resonance technique. The resulting mass excess of $^{149}$La differs by 221 keV from a recent JYFLTRAP measurement, resulting in a significant change in the profile of the two-neutron separation energy for that isotopic chain. The mass excesses of $^{149}$Ce and $^{149}$Pr are determined with an eight-fold improvement in precision compared to previous time-of-flight ion-cyclotron-resonance measurements; the $^{149}$Ce value is consistent with AME2020, while the $^{149}$Pr mass excess is lower by 17.5 keV. The mass excesses of $^{149}$La and $^{149}$Pr reported in this work have been confirmed recently by a measurement with a multi-reflection time-of-flight mass spectrometer coupled to a $\beta$-time of flight detector at RIKEN, providing further validation of the present results.

nucl-ex

Exploration for Astromers near $^{132}$Sn with the Canadian Penning Trap

Nuclear isomers can have significant impacts on astrophysical nucleosynthesis processes, with recent efforts demonstrating that the population of isomeric states with different half-lives may require separate treatment in reaction networks to accurately capture the differences in heating or in identifiable electromagnetic signals. Several potential so-called ``astromers'' in tin and antimony isotopes near doubly-magic $^{132}$Sn were identified and direct mass measurements of their ground and isomeric states were performed with the Canadian Penning Trap at Argonne National Laboratory's CARIBU facility, and their impact on astrophysical reaction rates and in reaction networks calculated. It was found that $^{129g,m}$Sn, with measured mass excesses of $-80 593.2(25)$ keV and $-80 557.4(25)$ keV, respectively, and an excitation energy of $35.8(35)$ keV, behaves as an astromer during neutron capture in the $i$-process and in the $r$-process.

nucl-ex

Off-line Commissioning of the St. Benedict Radiofrequency Quadrupole Cooler-Buncher

The St. Benedict ion trapping system, which aims to measure the $\beta-\nu$ angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the $V_{ud}$ element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width. The commissioning results also determined the trapping efficiency to be 93(1)$\%$ and the trapping half-life to be 20.0(5) s.

physics.ins-det

Astrophysical significance of the isomer $^{119m}$Ag demonstrated through direct mass measurement

The abundance of elements heavier than iron produced via the astrophysical rapid-neutron capture process depends sensitively on the atomic mass of the involved nuclei as well as the behavior of a few special types of nuclear isomers called astromers. High-precision mass measurements of $^{119}$Cd, $^{119}$Ag and their respective isomeric states have been performed with the Phase Imaging-Ion Cyclotron Resonance (PI-ICR) method with a precision of $\delta m/m \approx 10^{-8}$ using the Canadian Penning Trap (CPT). The ground state mass excess, as well as the excitation energy, agrees with recent Penning Trap measurements from JYFLTRAP. Network calculations using these new measurements revealed that, contrary to previous expectations, $^{119m}$Ag behaves as an astromer which significantly affects the population of $^{119}$Ag.

nucl-ex

Investigating the effects of precise mass measurements of Ru and Pd isotopes on machine learning mass modeling

Atomic masses are a foundational quantity in our understanding of nuclear structure, astrophysics and fundamental symmetries. The long-standing goal of creating a predictive global model for the binding energy of a nucleus remains a significant challenge, however, and prompts the need for precise measurements of atomic masses to serve as anchor points for model developments. We present precise mass measurements of neutron-rich Ru and Pd isotopes performed at the Californium Rare Isotope Breeder Upgrade facility at Argonne National Laboratory using the Canadian Penning Trap mass spectrometer. The masses of $^{108}$Ru, $^{110}$Ru and $^{116}$Pd were measured to a relative mass precision $\delta m/m \approx 10^{-8}$ via the phase-imaging ion-cyclotron-resonance technique, and represent an improvement of approximately an order of magnitude over previous measurements. These mass data were used in conjunction with the physically interpretable machine learning (PIML) model, which uses a mixture density neural network to model mass excesses via a mixture of Gaussian distributions. The effects of our new mass data on a Bayesian-updating of a PIML model are presented.

nucl-ex