arXiv Science⌕ Search

arXiv subjects

C. Macabiau

Publications and source records attributed to C. Macabiau.

6 recordsLinked to original sources

Euclid Data Release 1 (DR1). Near-infrared processing and data products

The Euclid near-infrared processing function (NIR PF) converts the raw observations acquired by the Near-Infrared Spectrometer and Photometer (NISP) into calibrated images and source-level products. Following the first implementation delivered with the Euclid Quick Data Release 1 (Q1), the NIR PF has been revised for the first major Euclid Data Release (DR1), with improvements to detector-level processing, calibration, image reconstruction, and quality control. The DR1 processing includes observations covering more than $1900\,\rm{deg}^2$ and has produced $71\,659$ calibrated near-infrared (NIR) images. We assess the performance of the processing chain through extensive astrometric and photometric validation. The astrometric solution reaches an average root-mean-square (RMS) of 10 mas, remaining below 20 mas for 99% of the dithers in all three NISP bands. Temporal variations in the instrumental throughput are typically corrected to a level of 2 mmag RMS, while the relative photometric accuracy reaches 0.9% for sources brighter than 19 mag in $Y_\mathrm{E}$, $J_\mathrm{E}$, and $H_\mathrm{E}$, and the residual spatial variations of the photometric calibration across the focal plane are at the level of approximately 10 mmag for the entire sample. Despite some remaining limitations, the DR1 NIR imaging products are consistent with the required astrometric and photometric performance over the large area covered by this release.

astro-ph.IM↗

Euclid Data Release 1 (DR1). NIR astrometric calibration

This paper presents the methodology and results of the astrometric calibration applied to the Euclid Near-Infrared (NIR) images in the Euclid Data Release 1, focusing on the techniques used to model and correct instrumental distortions, as well as the assessment of calibration quality. This work details the calibration pipeline, including quality control tests, and the evaluation of astrometric residuals against the Gaia DR3 catalogue and internal consistency metrics based on data encompassing more than one year of Euclid operation: the achieved accuracy is 30 mas for 97% of the total area, thus exceeding the requirements for Data Release 1. For the remaining 3%, accuracy declines due to a persistence correction issue: a method to correct the issue is presented. Furthermore, we discuss the stability of the solution over time, its dependence on source properties and instrument configuration, and outline the improvements planned for future Euclid data releases to enhance the astrometric calibration accuracy and efficiency.

astro-ph.IM↗

Euclid Data Release 1 (DR1) - NISP-P point-spread function modelling pipelines

The images collected in photometric mode by the Near-Infrared Spectrometer and Photometer (NISP) instrument of the Euclid satellite are used to model the point-spread function (PSF) of a selection of sources detected in single and combined frames. We used Q1 and DR1 data to improve the development of the PSF module of the near-infrared processing function (NIR PF) and to refine the models currently provided. We explored a few methods normally used to evaluate the quality of the derived models and discuss possible variations related to the position of the sources in the focal plane and to the wavelength and time of the observations. The procedure of fitting the PSF profile, compared to other methods used for flux estimation, such as aperture photometry, indicates that updated models are better than those provided by Q1 images. The current results are in agreement with several key requirements defined for the mission, but there is still room for further improvements, which we plan to investigate and implement in future releases.

astro-ph.IM↗

Euclid Data Release 1 (DR1). Persistence in NISP detectors

Detector persistence is a significant source of systematic error in infrared observations and affects the scientific performance of the \Euclid Near Infrared Spectrometer and Photometer (NISP). We characterise persistence using complementary ground calibration and in-flight data, develop empirical models of its temporal evolution, and assess its impact on science observations and the \Euclid data-processing pipeline. Persistence is highly non-uniform across the focal plane, with variations of up to two orders of magnitude between and within detectors. Its amplitude is typically below 1\% of the stimulus signal and depends nonlinearly on the preceding fluence. The decay rate is faster for brighter sources. During mission operations, the persistence signal has progressively decreased by roughly 10\%, while the decay rate has remained approximately stable. Persistence following over-saturating signals does not follow the empirical relations derived for under-saturating fluences and plausibly reduces persistence response over longer timescales. The impact of charge trapping and release on flat-field observations and on the background in science exposures is also discussed. Persistence measured in science observations is observed to differ systematically from that derived from dark calibration data. In addition, persistence of energetic particle hits is observed to be different from that of astronomical sources of comparable signal. Finally, we discuss the impact of persistence on \Euclid NISP observations and describe the masking strategy adopted for the Q1 abd DR1 releases, focusing on identifying which pixels are affected by persistence and for how long they should be excluded from science observations.

astro-ph.IM↗

Euclid preparation: The NISP spectroscopy channel, on ground performance and calibration

ESA's Euclid cosmology mission relies on the very sensitive and accurately calibrated spectroscopy channel of the Near-Infrared Spectrometer and Photometer (NISP). With three operational grisms in two wavelength intervals, NISP provides diffraction-limited slitless spectroscopy over a field of $0.57$ deg$^2$. A blue grism $\text{BG}_\text{E}$ covers the wavelength range $926$--$1366$\,nm at a spectral resolution $R=440$--$900$ for a $0.5''$ diameter source with a dispersion of $1.24$ nm px$^{-1}$. Two red grisms $\text{RG}_\text{E}$ span $1206$ to $1892$\,nm at $R=550$--$740$ and a dispersion of $1.37$ nm px$^{-1}$. We describe the construction of the grisms as well as the ground testing of the flight model of the NISP instrument where these properties were established.

astro-ph.IM↗

Euclid Quick Data Release (Q1). NIR processing and data products

This paper describes the near-infrared processing function (NIR PF) that processes near-infrared images from the Near-Infrared Spectrometer and Photometer (NISP) instrument onboard the Euclid satellite. NIR PF consists of three main components: (i) a common pre-processing stage for both photometric (NIR) and spectroscopic (SIR) data to remove instrumental effects; (ii) astrometric and photometric calibration of NIR data, along with catalogue extraction; and (iii) resampling and stacking. The necessary calibration products are generated using dedicated pipelines that process observations from both the early performance verification (PV) phase in 2023 and the nominal survey operations. After outlining the pipeline's structure and algorithms, we demonstrate its application to Euclid Q1 images. For Q1, we achieve an astrometric accuracy of 9-15 mas, a relative photometric accuracy of 5 mmag, and an absolute flux calibration limited by the 1% uncertainty of the Hubble Space Telescope (HST) CALSPEC database. We characterise the point-spread function (PSF) that we find very stable across the focal plane, and we discuss current limitations of NIR PF that will be improved upon for future data releases.

astro-ph.CO↗