arXiv ScienceSearch

arXiv subjects

C. Chambers

Publications and source records attributed to C. Chambers.

At least 19 recordsLinked to original sources

First direct measurement of $^{48}$Ca single $\beta$-decay Q value with the TITAN Penning trap

Neutrinoless double $\beta$-decay (0$\nu\beta\beta$), if observed, would provide unequivocal evidence of physics beyond the Standard Model. $^{48}$Ca is an interesting candidate system to study because it has the largest Q value among all 2$\beta$ transitions and is also unstable against single $\beta$-decay. The observation of both $\beta$ and 2$\beta$-decay in the same isotope would provide a unique opportunity to benchmark theoretical calculations of $\beta$ and 2$\beta$-decay matrix elements and could provide insight on the quenching of the axial vector coupling constant, g$_A$. We performed a precise measurement of the $^{48}$Ca $\beta$-decay Q value using the TITAN Penning trap mass spectrometer at the TRIUMF facility. This was achieved through cyclotron frequency ratio measurements of $^{48}$Ca$^{+}$/$^{48}$Sc$^{+}$ and $^{48}$Sc$^{+}$/$^{48}$Ti$^{+}$ using the Time-of-Flight Ion Cyclotron Resonance technique. The $^{48}$Ca $\beta$-decay Q value was determined to be 279.14(50) keV, a factor of 10 more precise than the previous value given in the 2020 Atomic Mass Evaluation [Chin. Phys. C 45, 030003 (2021)]. This Q value was used to determine the $^{48}$Ca $\beta$-decay partial half-life, with the result $T_{1/2}^{\beta}$ = 5.09(5) x 10$^{20}$ ($g_{A}^{-2}$) y. Our $^{48}$Ca $\beta$-decay half-life was determined to a precision of 1%, a factor of 30 improvement compared to calculations with the previous Q value. Our result is marginally closer to the experimental lower limit $T_{1/2}^{\beta}$ > 1.1 x 10$^{20}$ y, but still a factor 5 longer. It is also a factor of 10 longer than the observed 2$\nu\beta\beta$ decay mode with $T_{1/2}^{2\nu\beta\beta} = 5.96^{+1.39}_{-1.08}$ x 10$^{19}$ y. Hence, it could be possible to observe $^{48}$Ca $\beta$-decay in future experiments, strengthening the potential importance of $^{48}$Ca to benchmark nuclear structure and 2$\beta$-decay studies.

nucl-ex

Formation of gaseous, doubly charged cerium monofluoride CeF$^{2+}$ and its sensitivity to new physics

Tricationic protactinium monofluoride ($^{229}$PaF$^{3+}$) has been proposed as a candidate for probing physics beyond the Standard Model of particle physics. Since studies with $^{229}$PaF$^{3+}$ require significant experimental advances, we exploit the stable, valence-isoelectronic dicationic cerium monofluoride (CeF$^{2+}$) as a surrogate. Gas-phase fluorinated-cerium molecular ions are formed and identified using the Off-Line Ion Source and TITAN mass measurement facilities at TRIUMF. Quantum chemical calculations are performed on the electronic structure of CeF$^{2+}$, revealing a parallel to that of $^{229}$PaF$^{3+}$. Moreover, these calculations provide estimates on the sensitivity of CeF$^{2+}$ itself to various $\mathcal{P,T}$-odd properties. A brief discourse on the specifics of the quantum control of CeF$^{2+}$ is presented which anticipates future searches for symmetry violations.

physics.atom-ph

Mass measurements of $^{179-184}$Yb identify an anomalous proton-neutron interaction

Mass measurements of nuclei can identify structurally-driven trends in binding energy across isotopic chains, and can also isolate specific nucleon-nucleon interactions, such as the $\delta V_{\mathrm{pn}}$ interaction of the last two valence protons with the last two valence neutrons. Below $^{208}$Pb, investigation of the local binding energy and $\delta V_{\mathrm{pn}}$ systematics can facilitate a better understanding of the behaviour of the proton-neutron interaction in the 'hole-hole' regime (where valence interactions can be modelled in hole-space rather than particle-space) and provide insight on the potential onset of a prolate-to-oblate shape transition. However, measurement of the necessary nuclei has been exceptionally challenging. Here we present six first-time measurements of neutron-rich ytterbium, using advanced rare isotope production and mass spectrometry techniques, leading to the identification of an anomalously strong proton-neutron interaction in the 'hole-hole' quadrant below $^{208}$Pb. The scale of this interaction, at $^{186}$Hf, is comparable to that of similar signals at doubly-magic nuclei and shape transitions. The experimental results are compared with contemporary mean-field model predictions, that do not accurately reproduce the anomaly. The results are also used to benchmark predictions from several models, to facilitate more accurate descriptions towards a key r-process waiting point at $N = 126$.

nucl-ex

Search for Double Beta Decays of $^{134}$Xe with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% $^{136}$Xe and 19.098% $^{134}$Xe. The detector operated at WIPP between 2010 and 2018 and was designed to search for double beta decay of $^{136}$Xe. Data was acquired in two phases separated by a period of detector upgrades. We report on the search for $0\nu\beta\beta$ and $2\nu\beta\beta$ decay of $^{134}$Xe with Phase II EXO-200 data, with median 90% C.L. exclusion sensitivity $T_{1/2}^{0\nu} \geq 3.7\times 10^{23}$ yr and $T_{1/2}^{2\nu} \geq 2.6 \times 10^{21}$ yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of $^{134}$Xe of $T_{1/2}^{0\nu} \geq 8.7\times10^{23}$ (90% C.L.) and the second strongest constraint on the two-neutrino decay of $T_{1/2}^{2\nu} \geq 2.9\times10^{21}$ (90% C.L.), a 3-fold improvement over the EXO-200 Phase I measurement. New constraints are also set for the $2\nu\beta\beta$ and $0\nu\beta\beta$ decays of $^{134}$Xe to the lowest excited state of $^{134}$Ba.

nucl-ex

Exploring the Onset of Collectivity Approaching N=40 through Manganese Masses

Isotopes in the region of the nuclear chart below $^{68}\mathrm{Ni}$ have been the subject of intense experimental and theoretical effort due to the potential onset of a new ``island of inversion'' when crossing the harmonic oscillator subshell closure at $N = 40$. We have measured the masses of $^{64-68}\textrm{Mn}$ using TITAN's multiple-reflection time-of-flight mass spectrometer, resulting in the first precision mass measurements of $^{67}\mathrm{Mn}$ and $^{68}\mathrm{Mn}$. These results are compared to \textit{ab initio} calculations and modern shell model calculations and show an increase in collectivity approaching $N=40$.

nucl-ex

Characterization of external cross-talk from silicon photomultipliers in a liquid xenon detector

The Light-only Liquid Xenon experiment (LoLX) employs a small-scale detector equipped with 96 Hamamatsu VUV4 silicon photomultipliers (SiPMs) submerged in 5 kg of liquid xenon (LXe) to perform characterization measurements of light production, transport and detection in xenon. In this work, we perform a novel measurement of the "external cross-talk" (ExCT) of SiPMs, where photons produced in the avalanche process escape the device and produce correlated signals on other SiPMs. SiPMs are the photodetector technology of choice for next generation rare-event search experiments; understanding the sources and effects of correlated noise in SiPMs is critical for producing accurate estimates of detector performance and sensitivity projections. We measure the probability to observe ExCT through timing correlation of detected photons in low-light conditions within LoLX. Measurements of SiPM ExCT are highly detector dependent; thus the ExCT process is simulated and modelled using the Geant4 framework. Using the simulation, we determine the average transport and detection efficiency for ExCT photons within LoLX, a necessary input to extract the expected ExCT probability from the data. For an applied overvoltage of 4 V and 5 V, we measure a mean number of photons emitted into the LXe per avalanche of $0.5^{+0.3}_{-0.2}$ and $0.6^{+0.3}_{-0.2}$, respectively. Using an optical model to describe photon transmission through the SiPM surface, this corresponds to an estimated photon yield inside the bulk silicon of $20^{+11}_{-9}$ and $25^{+12}_{-9}$ photons per avalanche. The relative increase in intensity of SiPM ExCT emission between 4 V and 5 V is consistent with expectation for the linear increase of gain with respect to overvoltage.

physics.ins-det

Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

physics.atom-ph

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.

physics.ins-det

Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

hep-ex

'Searching for a needle in a haystack;' A Ba-tagging approach for an upgraded nEXO experiment

nEXO is a proposed experiment that will search for neutrinoless double-beta decay (0$\nu\beta\beta$) in 5-tonnes of liquid xenon (LXe), isotopically enriched in $^{136}$Xe. A technique called Ba-tagging is being developed as a potential future upgrade for nEXO to detect the $^{136}$Xe double-beta decay daughter isotope, $^{136}$Ba. An efficient Ba-tagging technique has the potential to boost nEXO's 0$\nu\beta\beta$ sensitivity by essentially suppressing non-double-beta decay background events. A conceptual approach for the extraction from the detector volume, trapping, and identification of a single Ba ion from 5 tonnes of LXe is presented, along with initial results from the commissioning of one of its subsystems, a quadrupole mass filter.

nucl-ex

Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset

A new search for two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2\nu\beta\beta$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2\nu\beta\beta$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2\nu}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.

hep-ex

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$\nu \beta \beta$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$\nu \beta \beta$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

Search for MeV Electron Recoils from Dark Matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_\chi = 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.

hep-ex

Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset

A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.

hep-ex

Characterization of a Spatially Resolved Multi-Element Laser Ablation Ion Source

A laser ablation ion source (LAS) is a powerful tool by which diverse species of ions can be produced for mass spectrometer calibration, or surface study applications. It is necessary to frequently shift the laser position on the target to selectively ablate materials in a controlled manner, and to mitigate degradation of the target surface caused by ablation. An alternative to mounting the target onto a rotation wheel or $x-y$ translation stage, is to shift the laser position with a final reflection from a motorized kinematic mirror mount. Such a system has been developed, assembled and characterized with a two axis motorized mirror and various metal targets. In the system presented here, ions are ablated from the target surface and guided by a 90 degree quadrupole bender to a Faraday cup where the ion current is measured. Spatially resolved scans of the target are produced by actuating the mirror motors, thus moving the laser spot across the target, and performing synchronous measurements of the ion current to construct 2D images of a target surface which can be up to 50~mm in diameter. The spatial resolution of the system has been measured by scanning the interfaces between metals such as steel and niobium, where it was demonstrated that the LAS can selectively ablate an area of diameter $\approx$50 $\mu$m. This work informs the development of subsequent LAS systems, that are intended to serve as multi-element ion sources for commercial and custom-built time-of-flight mass spectrometers, or to selectively study surface specific regions of samples.

physics.ins-det

The EXO-200 detector, part II: Auxiliary Systems

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

physics.ins-det

NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity

The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

nucl-ex

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of M\"unster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45{\deg} angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20{\deg} for the four samples and increases to up to 65% at 70{\deg} for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

physics.ins-det