arXiv ScienceSearch

arXiv subjects

Benoit Lefebvre

Publications and source records attributed to Benoit Lefebvre.

4 recordsLinked to original sources

Calibration of scintillator-based X-ray detectors for broadband laser-driven X-ray radiation

Laser-driven X-ray sources produce broadband radiation with substantial shot-to-shot fluctuations, requiring calibrated detector-response models for quantitative measurements of photon fluence and spectral distribution. Scintillator-based flat-panel detectors, originally developed primarily for medical and industrial X-ray imaging, are increasingly being adopted for diagnostics of laser-plasma-based X-ray sources because they provide large-area, spatially resolved detection. We report the calibration of two complementary X-ray detector systems: a CsI:Tl-based flat-panel detector and a plastic-scintillator filter-stack spectrometer intended for spectral reconstruction. Both detectors were characterized using well-defined ISO 4037 N-series reference radiation qualities, providing controlled polychromatic X-ray fields for establishing their signal response and signal-to-fluence conversion.

physics.optics

High Rate Studies of the ATLAS sTGC Detector and Optimization of the Filter Circuit on the Input of the Front-End Amplifier

The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5 - 7.5 $\times$ 10$^{34}$cm$^{-2}$ s$^{-1}$. This represents a more than 3-4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

physics.ins-det

Muon Spectrometer Phase-I Upgrade for the ATLAS Experiment: the New Small Wheel project

The instantaneous luminosity of the Large Hadron Collider at CERN will be increased by up to a factor of five to seven with respect to the design value. To maintain an excellent detection and background rejection capability in the forward region of the ATLAS detector, part of the muon detection system will be upgraded during LHC shutdown periods with the replacement of part of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs will have a diameter of approximately 10 m and will be made of two detector technologies: Micromegas and small-strip Thin Gap Chambers (sTGC). The physics motivation for this significant upgrade to the ATLAS detector will be presented. The design choices made to address the physics needs will be discussed. Finally, the status of the production of the detector modules will be presented.

physics.ins-det

Performance of a Full-Size Small-Strip Thin Gap Chamber Prototype for the ATLAS New Small Wheel Muon Upgrade

The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs will be installed during the LHC long shutdown in 2018/19. Small-Strip Thin Gap Chamber (sTGC) detectors are designed to provide fast trigger and high precision muon tracking under the high luminosity LHC conditions. To validate the design, a full-size prototype sTGC detector of approximately 1.2 $\times$ $1.0\, \mathrm{m}^2$ consisting of four gaps has been constructed. Each gap provides pad, strip and wire readouts. The sTGC intrinsic spatial resolution has been measured in a $32\, \mathrm{GeV}$ pion beam test at Fermilab. At perpendicular incidence angle, single gap position resolutions of about $50\,\mathrm{\mu m}$ have been obtained, uniform along the sTGC strip and perpendicular wire directions, well within design requirements. Pad readout measurements have been performed in a $130\, \mathrm{GeV}$ muon beam test at CERN. The transition region between readout pads has been found to be $4\,\mathrm{mm}$, and the pads have been found to be fully efficient.

physics.ins-det