arXiv ScienceSearch

arXiv subjects

Benjamin N. Frey

Publications and source records attributed to Benjamin N. Frey.

2 recordsLinked to original sources

Lens-Aware Differentiable Beamforming for In Vivo Distributed Aberration Correction with Curvilinear Transducers

We previously introduced ultrasound autofocusing, an iterative model-based aberration correction technique that estimates local sound speed and incorporates it into beamforming to correct image distortion from heterogeneous media. In this work, we extend ultrasound autofocusing to curvilinear arrays and introduce advancements to the underlying model. A differentiable bent-ray tracing approach accounts for refraction through the transducer lens, while a new adaptive-grid initialization accounts for changes in speckle position with sound speed. The method is validated in silico and in calibrated sound speed phantoms. Our distributed aberration-correction method is then applied to a first large-scale in vivo evaluation comprising 313 liver acquisitions from 76 high-BMI human subjects. In images containing anechoic regions, contrast and CNR improved by $1.38 \pm 1.60$ dB (+18.0%) and $0.09 \pm 0.14$ (+10.2%), respectively. Improvements were also observed in speckle brightness (+20.3%), coherence factor (+13.1%), lag-one coherence (+2.7%), common-midpoint correlation coefficient (+0.7%), and common-midpoint phase error (-9.1%; lower is better), with all metric improvements statistically significant. Target structure and visibility also improved significantly. These results demonstrate the potential of ultrasound autofocusing for clinically applicable distributed aberration correction.

physics.med-ph

Ultrasound Autofocusing: Common Midpoint Phase Error Optimization via Differentiable Beamforming

In ultrasound imaging, propagation of an acoustic wavefront through heterogeneous media causes phase aberrations that degrade the coherence of the reflected wavefront, leading to reduced image resolution and contrast. Adaptive imaging techniques attempt to correct this phase aberration and restore coherence, leading to improved focusing of the image. We propose an autofocusing paradigm for aberration correction in ultrasound imaging by fitting an acoustic velocity field to pressure measurements, via optimization of the common midpoint phase error (CMPE), using a straight-ray wave propagation model for beamforming in diffusely scattering media. We show that CMPE induced by heterogeneous acoustic velocity is a robust measure of phase aberration that can be used for acoustic autofocusing. CMPE is optimized iteratively using a differentiable beamforming approach to simultaneously improve the image focus while estimating the acoustic velocity field of the interrogated medium. The approach relies solely on wavefield measurements using a straight-ray integral solution of the two-way time-of-flight without explicit numerical time-stepping models of wave propagation. We demonstrate method performance through in silico simulations, in vitro phantom measurements, and in vivo mammalian models, showing practical applications in distributed aberration quantification, correction, and velocity estimation for medical ultrasound autofocusing.

physics.med-ph