arXiv ScienceSearch

arXiv subjects

Baibhab Chatterjee

Publications and source records attributed to Baibhab Chatterjee.

At least 19 recordsLinked to original sources

Bidirectional Wireless Communication for Weakly Coupled Implantable Brain-Computer Interfaces

Implantable brain-computer interfaces (BCIs) promise transformative societal impact, from restoring lost motor, sensory, and speech function in patients with paralysis, stroke, sclerosis, and sensory deficits to serving as a high-bandwidth conduit between human cognition and machine intelligence. Realizing these visions requires moving from laboratory prototypes to chronic clinical systems that support thousands to millions of electrodes, several millimeters to centimeters deep beneath the brain surface, under strict heating and size limits. Almost every clinically relevant implant therefore operates in a weakly coupled regime, with coupling coefficients of $10^{-3}$ to $10^{-1}$ across centimetres of lossy tissue. In this regime, the wireless channel sets the limits of power-transfer efficiency, communication bandwidth, and energy per bit. We review the recent progress of bidirectional wireless links across inductive, mid-field, RF, ultrasonic, magnetoelectric, optical, UWB, and electro-quasistatic modalities, and benchmark them against the clinical axes of depth, size, and data rate. Within an approximately 10 mW communication budget set by the approximately $1^\circ$C tissue-heating ceiling, narrowband high-Q links are well suited for power transfer and low-speed data, but at 1-10 nJ/b cannot reach the greater than 10 Mbps to tens of Gbps uplinks that thousand- to million-channel interfaces demand, even with aggressive on-implant compression. This calls for sub-10 pJ/b and ultimately sub-1 pJ/b wireless links, where wideband techniques, such as ultra-wideband (UWB) and brain-channel communication (BCC), are suitable. We close with a quantitative framework for analyzing such wireless links and a co-design roadmap across electromagnetics, circuits, packaging, security, and regulation, toward secure, networked, million-channel brain interfaces.

eess.SY

FrequencyFormer: A Co-Designed Sensor-to-Processor Pipeline for Frequency-Domain Vision Transformer Inference

Deploying vision transformers (ViTs) on sensor-edge systems is limited not only by on-device compute, but also by the energy and bandwidth required to transmit high-dimensional image data from the sensor to the processor. While in-sensor and near-sensor computing reduce this cost through early feature extraction, existing methods often provide only modest compression. We observe that the frequency domain provides a naturally compact representation of visual information and can be exploited at the sensor level to reduce sensor-to-processor data movement. Building on this insight, we present FrequencyFormer, a co-designed sensor-to-processor pipeline for efficient ViT inference. FrequencyFormer includes: (1) a multi-scale DCT tokenizer that compresses a 224x224 image into compact frequency-domain tokens, achieving up to 128x reduction in off-chip data volume with modest accuracy loss; (2) a LUT-based near-sensor hardware implementation that leverages fixed DCT coefficients for multiplier-free, energy- and area-efficient tokenization; and (3) a modified MIPI-based low-power communication architecture that further reduces transfer energy. FrequencyFormer serves as a drop-in replacement for standard ViT patch embedding and remains compatible with pretrained backbones across classification, detection, and segmentation tasks. The pipeline achieves 28.8 TOPS/W, reduces communication energy by 230x, and lowers total sensor-side energy by 2.22x, demonstrating frequency-domain tokenization as a scalable foundation for in-sensor ViT deployment.

eess.IV

Characterizing the Impact of NVFP4 Quantization for Low-Power Edge AI Deployment

Energy-efficient neural-network inference at the edge requires reducing arithmetic cost, memory traffic, computation energy, and storage overhead while maintaining acceptable accuracy. This paper presents an ablation-focused study of NVFP4 quantization for edge-efficient neural networks, with emphasis on the relationship between activation precision, weight precision, block-size scaling, retraining, and model accuracy. NVFP4 activations are represented using 4-bit FP4 data, an FP8 block scale, and an FP32 tensor scale, enabling ultra-low precision inference while preserving activation dynamic range. A block-size ablation over six edge-efficient models shows that block size B = 16 provides a practical accuracy/storage trade-off, requiring only 4.5078 bits per input for N = 4096. A weight precision ablation further shows that FP8 and FP16 weights provide only modest gains over FP4 weights under the same NVFP4 activation path, suggesting that activation quantization and scaling dominate much of the accuracy behavior. To isolate the benefit of the NVFP4 data type, this work compares conventional unscaled FP4 activation inference and NVFP4 activation inference with and without retraining. The results show that conventional FP4 inference collapses accuracy for most compact models, while NVFP4 without retraining already recovers substantial accuracy by restoring activation dynamic range through FP8 block scaling and FP32 tensor scaling. When combined with retraining, NVFP4 achieves the best accuracy across the evaluated models, demonstrating the effectiveness of scaling-aware FP4 (NVFP4) inference. These findings provide general design guidance for hardware-software co-design of low power edge inference across a broad range of accelerator platforms, including GPUs, Tensor Cores, FPGAs, domain-specific AI accelerators, near-memory computing systems, and emerging edge-computing architectures.

cs.AR

From the Two-Capacitor Paradox to Electromagnetic Side-Channel Mitigation in Digital Circuits

The classical two-capacitor paradox of the lost energy is revisited from an electronic circuit security stand-point. The paradox has been solved previously by various researchers, and the energy lost during the charging of capacitors has been primarily attributed to the heat and radiation. We analytically prove this for various standard resistor-capacitor (RC) and resistor-inductor-capacitor (RLC) circuit models. From the perspective of electronic system security, electromagnetic (EM) side-channel analysis (SCA) has recently gained significant prominence with the growth of resource-constrained, internet connected devices. This article connects the energy lost due to capacitor charging to the EM SCA leakage in electronic devices, leading to the recovery of the secret encryption key embedded within the device. Finally, with an understanding of how lost energy relates to EM radiation, we propose adiabatic charging as a solution to minimize EM leakage, thereby paving the way towards low-overhead EM SCA resilience.

cs.CR

Low-Latency Neural Inference on an Edge Device for Real-Time Handwriting Recognition from EEG Signals

Brain-computer interfaces (BCIs) offer a pathway to restore communication for individuals with severe motor or speech impairments. Imagined handwriting provides an intuitive paradigm for character-level neural decoding, bridging the gap between human intention and digital communication. While invasive approaches such as electrocorticography (ECoG) achieve high accuracy, their surgical risks limit widespread adoption. Non-invasive electroencephalography (EEG) offers safer and more scalable alternatives but suffers from low signal-to-noise ratio and spatial resolution, constraining its decoding precision. This work demonstrates that advanced machine learning combined with informative EEG feature extraction can overcome these barriers, enabling real-time, high-accuracy neural decoding on portable edge devices. A 32-channel EEG dataset was collected from fifteen participants performing imagined handwriting. Signals were preprocessed with bandpass filtering and artifact subspace reconstruction, followed by extraction of 85 time-, frequency-, and graphical-domain features. A hybrid architecture, EEdGeNet, integrates a Temporal Convolutional Network with a multilayer perceptron trained on the extracted features. When deployed on an NVIDIA Jetson TX2, the system achieved 89.83 percent accuracy with 914.18 ms per-character latency. Selecting only ten key features reduced latency by 4.5 times to 202.6 ms with less than 1 percent loss in accuracy. These results establish a pathway for accurate, low-latency, and fully portable non-invasive BCIs supporting real-time communication.

eess.SP

A Systematic Method for Optimum Biomedical Wireless Power Transfer using Inductive Links in Area-Constrained Implants

In the context of implantable bioelectronics, this work provides new insights into maximizing biomedical wireless power transfer (BWPT) via the systematic development of inductive links. This approach addresses the specific challenges of power transfer efficiency (PTE) optimization within the area constraints of bio-implants embedded in tissue. Key contributions include the derivation of an optimal self-inductance with S-parameter-based analyses leading to the co-design of planar spiral coils and L-section impedance matching networks. To validate the proposed design methodology, two coil prototypes -- one symmetric (type-1) and one asymmetric (type-2) -- were fabricated and tested for PTE in pork tissue. Targeting a 20 MHz design frequency, the type-1 coil demonstrated a state-of-the-art PTE of $\sim$ 4\% (channel length = 15 mm) with a return loss (RL) $>$ 20 dB on both the input and output sides, within an area constraint of $<$ 18 $ \times $ 18 mm$^{2}$. In contrast, the type-2 coil achieved a PTE of $\sim$ 2\% with an RL $>$ 15 dB, for a smaller receiving coil area of $<$ 5x5 mm$^{2}$ for the same tissue environment. To complement the coils, we demonstrate a 65 nm test chip with an integrated energy harvester, which includes \asif{a} 30-stage rectifier and low-dropout regulator (LDO), producing a stable $\sim$ 1V DC output within tissue medium, matching theoretical predictions and simulations. Furthermore, we provide a robust and comprehensive guideline for advancing efficient inductive links for various BWPT applications, with shared resources in GitHub available for utilization by the broader community.

eess.SP

Galvanic Body-Coupled Powering for Wireless Implanted Neurostimulators

Body-coupled powering (BCP) is an innovative wireless power transfer (WPT) technique, recently explored for its potential to deliver power to cutting-edge biomedical implants such as nerve and muscle stimulators. This paper demonstrates the efficient technique of designing WPT systems embedding BCP via galvanic coupling (G-BCP). The G-BCP configuration utilizes two metal circular rings surrounding the body area of interest as the transmitter (TX) electrodes required for galvanic (differential) excitation and a wireless implant as the receiver (RX) equipped with two electrodes for differential power reception accordingly. By focusing on the unique advantages of this approach - such as enhanced targeting accuracy, improved power transfer efficiency (PTE), and favorable tissue penetration characteristics, G-BCP emerges as a superior alternative to traditional WPT methods. A comprehensive analysis is conducted to obtain the optimized device parameters while simultaneously allowing flexible placement of implants at different depths and alignments. To substantiate the proposed design concept, a prototype was simulated in Ansys HFSS, employing a multi-layered tissue medium of 10mm radius and targeting the sciatic nerve of a rat. Impressively, this prototype achieves > 20% PTE at 1.25 GHz, with the implant (radius of RX electrodes = 1 mm) located 2 mm deep inside the tissue model having complex load impedance of Rload = 1000 Ohm and Cload = 5pF. Therefore, the G-BCP-based wirelessly powered microdevices are envisaged to be a key enabler in neural recording and stimulation, specifically for the peripheral nervous system, enhancing therapeutic outcomes and patient experiences.

eess.SP

dAJC: A 2.02mW 50Mbps Direct Analog to MJPEG Converter for Video Sensor Node using Low-Noise Switched Capacitor MAC-Quantizer with Auto-Calibration and Sparsity-Aware ADC

With the advancement in the field of the Internet of Things(IoT) and Internet of Bodies(IoB), video camera applications using Video Sensor Nodes(VSNs) have gained importance in the field of autonomous driving, health monitoring, robot control, and security camera applications. However, these applications typically involve high data rates due to the transmission of high-resolution video signals, resulting from high data volume generated from the analog-to-digital converters (ADCs). This significant data deluge poses processing and storage overheads, exacerbating the problem. To address this challenge, we propose a low-power solution aimed at reducing the power consumption in Video Sensor Nodes (VSNs) by shifting the computation from the digital domain to the inherently energy-efficient analog domain. Unlike standard architectures where computation and processing are typically performed in digital signal processing (DSP) blocks after the ADCs, our approach eliminates the need for such blocks. Instead, we leverage a switched capacitor-based computation unit in the analog domain, resulting in a reduction in power consumption. We achieve a $\sim4X$ reduction in power consumption compared to digital implementations. Furthermore, we employ a sparsity-aware ADC, which is enabled only for significant compressed samples that contribute to a small fraction ($\le5\%$) of the total captured analog samples, we achieve a $\sim20X$ lower ADC conversion energy without any considerable degradation, contributing to the overall energy savings in the system.

eess.SP

Implant-to-Wearable Communication through the Human Body: Exploring the Effects of Encapsulated Capacitive and Galvanic Transmitters

Data transfer using human-body communication (HBC) represents an actively explored alternative solution to address the challenges related to energy-efficiency, tissue absorption, and security of conventional wireless. Although the use of HBC for wearable-to-wearable communication has been well-explored, different configurations for the transmitter (Tx) and receiver (Rx) for implant-to-wearable HBC needs further studies. This paper substantiates the hypothesis that a fully implanted galvanic Tx is more efficient than a capacitive Tx for interaction with a wearable Rx. Given the practical limitations of implanting an ideal capacitive device, we choose a galvanic device with one electrode encapsulated to model the capacitive scenario. We analyze the lumped circuit model for in-body to out-of-body communication, and perform Circuit-based as well as Finite Element Method (FEM) simulations to explore how the encapsulation thickness affects the received signal levels. We demonstrate in-vivo experimental results on live Sprague Dawley rats to validate the hypothesis, and show that compared to the galvanic Tx, the channel loss will be $\approx$ 20 dB higher with each additional mm thickness of capacitive encapsulation, eventually going below the noise floor for ideal capacitive Tx.

q-bio.TO

Look-Up Table based Neural Network Hardware

Traditional digital implementations of neural accelerators are limited by high power and area overheads, while analog and non-CMOS implementations suffer from noise, device mismatch, and reliability issues. This paper introduces a CMOS Look-Up Table (LUT)-based Neural Accelerator (LUT-NA) framework that reduces the power, latency, and area consumption of traditional digital accelerators through pre-computed, faster look-ups while avoiding noise and mismatch of analog circuits. To solve the scalability issues of conventional LUT-based computation, we split the high-precision multiply and accumulate (MAC) operations into lower-precision MACs using a divide-and-conquer-based approach. We show that LUT-NA achieves up to $29.54\times$ lower area with $3.34\times$ lower energy per inference task than traditional LUT-based techniques and up to $1.23\times$ lower area with $1.80\times$ lower energy per inference task than conventional digital MAC-based techniques (Wallace Tree/Array Multipliers) without retraining and without affecting accuracy, even on lottery ticket pruned (LTP) models that already reduce the number of required MAC operations by up to 98%. Finally, we introduce mixed precision analysis in LUT-NA framework for various LTP models (VGG11, VGG19, Resnet18, Resnet34, GoogleNet) that achieved up to $32.22\times$-$50.95\times$ lower area across models with $3.68\times$-$6.25\times$ lower energy per inference than traditional LUT-based techniques, and up to $1.35\times$-$2.14\times$ lower area requirement with $1.99\times$-$3.38\times$ lower energy per inference across models as compared to conventional digital MAC-based techniques with $\sim$1% accuracy loss.

cs.AR

LUNA-CIM: Lookup Table based Programmable Neural Processing in Memory

This paper presents a novel approach for performing computations using Look-Up Tables (LUTs) tailored specifically for Compute-in-Memory applications. The aim is to address the scalability challenges associated with LUT-based computation by reducing storage requirements and energy consumption while capitalizing on the faster and more energy-efficient nature of look-up methods compared to conventional mathematical computations. The proposed method leverages a divide and conquer (D&C) strategy to enhance the scalability of LUT-based computation. By breaking down high-precision multiplications into lower-precision operations, the technique achieves significantly lower area overheads, up to approximately 3.7 times less than conventional LUT-based approaches, without compromising accuracy. To validate the effectiveness of the proposed method, extensive simulations using TSMC 65 nm technology were conducted. The experimental analysis reveals that the proposed approach accounts for less than 0.1\% of the total energy consumption, with only a 32\% increase in area overhead. These results demonstrate considerable improvements achieved in energy efficiency and area utilization through the novel low-energy, low-area-overhead LUT-based computation in an SRAM array.

cs.AR

Modified Ring-Oscillator Physical Unclonable Function (RO-PUF) based PRBS Generation as a Device Signature in Distributed Brain Implants

In this paper, we propose and evaluate a method of generating low-cost device signatures for distributed wireless brain implants, using a Pseudo-Random Binary Sequence (PRBS) Generator that utilizes a modified Ring-Oscillator-based Physical Unclonable Function (RO-PUF). The modified RO-PUF's output is used as a seed for the PRBS generator, which creates a multi-bit output that can be mapped to a time-slot when the implant is allowed to communicate with the external world using duty-cycled time-division multiplexing. A 9-bit PRBS generator is shown in hardware (with a TSMC 65 nm test chip implementation) that demonstrates < 100 nW Power consumption in measurement (72% lower power and 78% lower area than a traditional 9-bit RO-PUF implementation), which supports 26 implants with the probability of time-slot collision being < 50%. This potentially creates a pathway for low-cost device signature generation for highly resource-constrained scenarios such as wireless, distributed neural implants.

cs.NI

Bioelectronic Sensor Nodes for Internet of Bodies

Energy-efficient sensing with Physically-secure communication for bio-sensors on, around and within the Human Body is a major area of research today for development of low-cost healthcare, enabling continuous monitoring and/or secure, perpetual operation. These devices, when used as a network of nodes form the Internet of Bodies (IoB), which poses certain challenges including stringent resource constraints (power/area/computation/memory), simultaneous sensing and communication, and security vulnerabilities as evidenced by the DHS and FDA advisories. One other major challenge is to find an efficient on-body energy harvesting method to support the sensing, communication, and security sub-modules. Due to the limitations in the harvested amount of energy, we require reduction of energy consumed per unit information, making the use of in-sensor analytics/processing imperative. In this paper, we review the challenges and opportunities in low-power sensing, processing and communication, with possible powering modalities for future bio-sensor nodes. Specifically, we analyze, compare and contrast (a) different sensing mechanisms such as voltage/current domain vs time-domain, (b) low-power, secure communication modalities including wireless techniques and human-body communication, and (c) different powering techniques for both wearable devices and implants.

cs.NI

Sub-1ms Instinctual Interference Adaptive GaN LNA Front-End with Power and Linearity Tuning

One of the major challenges in communication, radar, and electronic warfare receivers arises from nearby device interference. The paper presents a 2-6 GHz GaN LNA front-end with onboard sensing, processing, and feedback utilizing microcontroller-based controls to achieve adaptation to a variety of interference scenarios through power and linearity regulations. The utilization of GaN LNA provides high power handling capability (30 dBm) and high linearity (OIP3= 30 dBm) for radar and EW applications. The system permits an LNA power consumption to tune from 500 mW to 2 W (4X increase) in order to adjust the linearity from P\textsubscript{1dB,IN}=-10.5 dBm to 0.5 dBm (>10X increase). Across the tuning range, the noise figure increases by approximately 0.4 dB. Feedback control methods are presented with backgrounds from control theory. The rest of the controls consume $\leq$10$\%$ (100 mW) of nominal LNA power (1 W) to achieve an adaptation time <1 ms.

eess.SP

TD-BPQBC: A 1.8{\mu}W 5.5mm3 ADC-less Neural Implant SoC utilizing 13.2pJ/Sample Time-domain Bi-phasic Quasi-static Brain Communication

Untethered miniaturized wireless neural sensor nodes with data transmission and energy harvesting capabilities call for circuit and system-level innovations to enable ultra-low energy deep implants for brain-machine interfaces. Realizing that the energy and size constraints of a neural implant motivate highly asymmetric system design (a small, low-power sensor and transmitter at the implant, with a relatively higher power receiver at a body-worn hub), we present Time-Domain Bi-Phasic Quasi-static Brain Communication (TD- BPQBC), offloading the burden of analog to digital conversion (ADC) and digital signal processing (DSP) to the receiver. The input analog signal is converted to time-domain pulse-width modulated (PWM) waveforms, and transmitted using the recently developed BPQBC method for reducing communication power in implants. The overall SoC consumes only 1.8{\mu}W power while sensing and communicating at 800kSps. The transmitter energy efficiency is only 1.1pJ/b, which is >30X better than the state-of-the-art, enabling a fully-electrical, energy-harvested, and connected in-brain sensor/stimulator node.

q-bio.NC

Bi-Phasic Quasistatic Brain Communication for Fully Untethered Connected Brain Implants

Wireless communication using electro-magnetic (EM) fields acts as the backbone for information exchange among wearable devices around the human body. However, for Implanted devices, EM fields incur high amount of absorption in the tissue, while alternative modes of transmission including ultrasound, optical and magneto-electric methods result in large amount of transduction losses due to conversion of one form of energy to another, thereby increasing the overall end-to-end energy loss. To solve the challenge of powering and communication in a brain implant with low end-end channel loss, we present Bi-Phasic Quasistatic Brain Communication (BP-QBC), achieving < 60dB worst-case end-to-end channel loss at a channel length of 55mm, by avoiding the transduction losses during field-modality conversion. BP-QBC utilizes dipole coupling based signal transmission within the brain tissue using differential excitation in the transmitter and differential signal pick-up at the receiver, and offers 41X lower power w.r.t. traditional Galvanic Human Body Communication at a carrier frequency of 1MHz, by blocking any DC current paths through the brain tissue. Since the electrical signal transfer through the human tissue is electro-quasistatic up to several 10's of MHz range, BP-QBC allows a scalable (bps-10Mbps) duty-cycled uplink from the implant to an external wearable. The power consumption in the BP-QBC TX is only 0.52uW at 1Mbps (with 1% duty cycling), which is within the range of harvested body-coupled power in the downlink from an external wearable to the brain implant. Furthermore, BP-QBC eliminates the need for sub-cranial repeaters, as it utilizes quasi-static electrical signals, thereby avoiding any transduction losses. Such low end-to-end channel loss with high data rates would find applications in neuroscience, brain-machine interfaces, electroceuticals and connected healthcare.

q-bio.NC

Channel Modeling for Physically Secure Electro-Quasistatic In-Body to Out-of-Body Communication with Galvanic Tx and Multimodal Rx

Increasing number of devices being used in and around the human body has resulted in the exploration of the human body as a communication medium. In this paper, we design a channel model for implantable devices communicating outside the body using physically secure Electro-Quasistatic Human Body Communication. A galvanic receiver shows 5dB lower path loss than capacitive receiver when placed close to transmitter whereas a capacitive receiver has around 15dB lower path loss for larger separation between the transmitter and receiver. Finite Element Method (FEM) based simulations are used to analyze the communication channel for different receiver topologies and experimental data is used to validate the simulation results.

eess.SP

A Quantitative Analysis of Physical Security and Path Loss With Frequency for IBOB Channel

Security vulnerabilities demonstrated in implantable medical devices have opened the door for research into physically secure and low power communication methodologies. In this study, we perform a comparative analysis of commonly used ISM frequency bands and human body communication (HBC) for data transfer from in-body to out-of-body (IBOB). We develop a figure of merit (FoM) that comprises of the critical parameters to quantitatively compare the communication methodologies. We perform finite-element method (FEM)-based simulations and experiments to validate the FoM developed.

eess.SP