arXiv Science⌕ Search

arXiv subjects

B. Saggin

Publications and source records attributed to B. Saggin.

3 recordsLinked to original sources

Developing the Field Selector System for the SHARP Multi-IFU: Optomechanical Design and First Prototype Validation

This paper presents the innovative Field Selector System (FSS) developed for VESPER, the multi-Integral Field Unit of the SHARP near-infrared spectrograph. The proposed system employs an array of movable light-collection probes (Field Selectors) that travel along parallel, vertically offset planes to avoid mechanical interference and vignetting. The true novelty lies in its opto-mechanical synchronization: as each probe translates by Δy to select a target, a set of folding mirrors shifts by Δy/2. This maintains a constant optical path length, allowing multiple independently moving probes to share a single focal plane and form a continuous image on it, easy to slice by the slicer. A dedicated optical test setup was developed to characterize the positioning stability and repeatability of the probe motion. The measured mechanical errors were converted into equivalent optical tilts and incorporated into the SHARP optical model to assess their impact on instrument performance. The experimental results identified the dominant sources of positioning error and provided valuable insight into the relationship between mechanical tolerances and optical performance. The study also highlights several design improvements capable of significantly reducing probe tilting and enhancing system stability. The results demonstrate the viability of the proposed concept and indicate that, with the identified improvements, the system represents an excellent field-selection solution for SHARP and other multi-integral-field-unit (mIFU) spectrographs.

astro-ph.IM↗

Structural, thermal and optical tolerance analysis of SHARP, a near infrared spectrograph for next generation telescope

The design and verification of cryogenic near-infrared spectrographs require rigorous multidisciplinary analyses to ensure optical performance under realistic operational conditions. In this work, we present a structural-thermal-optical performance (STOP) analysis of the SHARP instrument, a multi-mode spectrograph designed for use with upcoming multi-conjugate adaptive optics (MCAO) systems on Extremely Large Telescopes (ELTs). Transient and steady-state thermal simulations were performed using Ansys to model the cooldown process and temperature distribution within the opto-mechanical structure. The resulting temperature fields were mapped to structural models through linear interpolation, enabling the evaluation of thermal stresses and deformations of optical elements. Optical sensitivity and tolerance analyses were carried out using Ansys Zemax OpticStudio, with Monte Carlo simulations applied to assess robustness against decenter, tilt, and despace errors. Results indicate that SHARP maintains RMS spot radius values within acceptance threshold, and that the inclusion of compensators significantly enhances compliance with the Ensquared Energy (EE) requirement across all channels. The analysis confirms that SHARP can achieves its optical performance goals while remaining within mechanical and thermal constraints, providing a validated framework for the development of next-generation cryogenic astronomical instrumentation.

astro-ph.IM↗

Toward a numerical deshaker for PFS

The Planetary Fourier Spectrometer (PFS) onboard Mars Express (MEx) is the instrument with the highest spectral resolution observing Mars from orbit since January 2004. It permits studying the atmospheric structure, major and minor compounds. The present time version of the calibration is limited by the effects of mechanical vibration, currently not corrected. We proposed here a new approach to correct for the vibrations based on semi-blind deconvolution of the measurements. This new approach shows that a correction can be done efficiently with 85% reduction of the artefacts, in a equivalent manner to the stacking of 10 spectra. Our strategy is not fully automatic due to the dependence on some regularisation parameters. It may be applied on the complete PFS dataset, correcting the large-scale perturbation due to microvibrations for each spectrum independently. This approach is validated on actual PFS data of Short Wavelength Channel (SWC), perturbed by microvibrations. A coherence check can be performed and also validate our approach. Unfortunately, the coherence check can be done only on the first 310 orbits of MEx only, until the laser line has been switch off. More generally, this work may apply to numerically "deshake" Fourier Transform Spectrometer (FTS), widely used in space experiments or in the laboratory.

astro-ph.IM↗