arXiv ScienceSearch

arXiv subjects

B. Cox

Publications and source records attributed to B. Cox.

At least 19 recordsLinked to original sources

The CMS Barrel Timing Layer: test beam confirmation of module timing performance

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm \mu m$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.

physics.ins-det

Fully three-dimensional sound speed-corrected multi-wavelength photoacoustic breast tomography

Photoacoustic tomography is a contrast agent-free imaging technique capable of visualizing blood vessels and tumor-associated vascularization in breast tissue. While sophisticated breast imaging systems have been recently developed, there is yet much to be gained in imaging depth, image quality and tissue characterization capability before clinical translation is possible. In response, we have developed a hybrid photoacoustic and ultrasound-transmission tomographic system PAM3. The photoacoustic component has for the first time three-dimensional multi-wavelength imaging capability, and implements substantial technical advancements in critical hardware and software sub-systems. The ultrasound component enables for the first time, a three-dimensional sound speed map of the breast to be incorporated in photoacoustic reconstruction to correct for inhomogeneities, enabling accurate target recovery. The results demonstrate the deepest photoacoustic breast imaging to date namely 48 mm, with a more uniform field of view than hitherto, and an isotropic spatial resolution that rivals that of Magnetic Resonance Imaging. The in vivo performance achieved, and the diagnostic value of interrogating angiogenesis-driven optical contrast as well as tumor mass sound speed contrast, gives confidence in the system's clinical potential.

physics.med-ph

Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.

physics.ins-det

RADiCAL: Precision-timing, Ultracompact, Radiation-hard Electromagnetic Calorimetry

To address the challenges of providing high performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCChh environments), we are conducting R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we are focusing our attention on ultra-compact radiation hard EM calorimeters, based on modular structures (RADiCAL modules) consisting of alternating layers of very dense absorber and scintillating plates, read out via radiation hard wavelength shifting (WLS) solid fiber or capillary elements to photosensors positioned either proximately or remotely, depending upon their radiation tolerance. The RADiCAL modules provide the capability to measure simultaneously and with high precision the position, energy and timing of EM showers. This paper provides an overview of the instrumentation and photosensor R&D associated with the RADiCAL program.

physics.ins-det

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

physics.ins-det

A Measurement of the Branching Ratio of $π^0$ Dalitz Decay using $K_L \rightarrow π^0π^0π^0$ Decays

We present a measurement of $B(π^0 \rightarrow e^+e^- γ)/B(π^0 \rightarrow γγ)$, the Dalitz branching ratio, using data taken in 1999 by the E832 KTeV experiment at Fermi National Accelerator Laboratory. We use neutral pions from fully reconstructed $K_L$ decays in flight; the measurement is based on about 60 thousand $K_L \rightarrow π^0π^0π^0 \rightarrow γγ~γγ~e^+e^-γ$ decays. We normalize to $K_L \rightarrow π^0π^0π^0 \rightarrow 6γ$ decays. We find $B(π^0 \rightarrow e^+e^- γ)/B(π^0 \rightarrow γγ)$ $(m_{e^+e^-}$ > 15 MeV/$c^2)$ = $[3.920 \pm 0.016(stat) \pm 0.036 (syst)] \times 10^{-3}$. Using the Mikaelian and Smith prediction for the $e^+e^-$ mass spectrum, we correct the result to the full $e^+e^-$ mass range. The corrected result is $B(π^0 \rightarrow e^+e^- γ)/B(π^0 \rightarrow γγ) = [1.1559 \pm 0.0047(stat) \pm 0.0106 (syst)]$%. This result is consistent with previous measurements and the uncertainty is a factor of three smaller than any previous measurement.

hep-ex

LHC Forward Physics

The goal of this report is to give a comprehensive overview of the rich field of forward physics, with a special attention to the topics that can be studied at the LHC. The report starts presenting a selection of the Monte Carlo simulation tools currently available, chapter 2, then enters the rich phenomenology of QCD at low, chapter 3, and high, chapter 4, momentum transfer, while the unique scattering conditions of central exclusive production are analyzed in chapter 5. The last two experimental topics, Cosmic Ray and Heavy Ion physics are presented in the chapter 6 and 7 respectively. Chapter 8 is dedicated to the BFKL dynamics, multiparton interactions, and saturation. The report ends with an overview of the forward detectors at LHC. Each chapter is correlated with a comprehensive bibliography, attempting to provide to the interested reader with a wide opportunity for further studies.

hep-ph

Search for the Rare Decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-

The KTeV E799 experiment has conducted a search for the rare decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-, where the X0 is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 pm 0.5) MeV/c^{2}. We find no evidence for either decay. We obtain upper limits of Br(KL->pi0pi0X0->pi0pi0mu+mu-) < 1.0 x 10^{-10} and Br(KL->pi0pi0mu+mu-) < 9.2 x 10^{-11} at the 90% confidence level. This result rules out the pseudoscalar X0 as an explanation of the HyperCP result under the scenario that the \bar{d}sX0 coupling is completely real.

hep-ex

Precise Measurements of Direct CP Violation, CPT Symmetry, and Other Parameters in the Neutral Kaon System

We present precise tests of CP and CPT symmetry based on the full dataset of K to pipi decays collected by the KTeV experiment at Fermi National Accelerator Laboratory during 1996, 1997, and 1999. This dataset contains 16 million K to 2pi0 and 69 million K to pi+pi- decays. We measure the direct CP violation parameter Re(epsilon'/epsilon) = (19.2 pm 2.1)x10-4. We find the KL-KS mass difference Deltam = (5270 pm 12)x10^6 hbar/s and the KS lifetime tauS = (89.62 pm 0.05)x10-12 s. We also measure several parameters that test CPT invariance. We find the difference between the phase of the indirect CP violation parameter, epsilon, and the superweak phase, phi_epsilon - phi_SW = (0.40 pm 0.56) degrees. We measure the difference of the relative phases between the CP violating and CP conserving decay amplitudes for K to pi+pi- (phi+-) and for K to 2pi0 (phi00), Delta phi = (0.30 pm 0.35) degrees. From these phase measurements, we place a limit on the mass difference between K0 and K0bar, DeltaM < 4.8 x 10-19 GeV/c^2 at 95% C.L. These results are consistent with those of other experiments, our own earlier measurements, and CPT symmetry.

hep-ex

Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.

physics.ins-det

Search for the Rare Decay K_{L}\toπ^{0}π^{0}γ

The KTeV E799 experiment has conducted a search for the rare decay $K_{L}\toπ^{0}π^{0}γ$ via the topology $K_{L}\toπ^{0}π^{0}_Dγ$ (where $π^0_D\toγe^+e^-$). Due to Bose statistics of the $π^0$ pair and the real nature of the photon, the $K_{L}\toπ^{0}π^{0}γ$ decay is restricted to proceed at lowest order by the CP conserving direct emission (DE) of an E2 electric quadrupole photon. The rate of this decay is interesting theoretically since chiral perturbation theory predicts that this process vanishes at level $O(p^4)$. Therefore, this mode probes chiral perturbation theory at $O(p^6)$. In this paper we report a determination of an upper limit of $2.43\times 10^{-7}$ (90% CL) for $K_{L}\toπ^{0}π^{0}γ$. This is approximately a factor of 20 lower than previous results.

hep-ex

Observation of the Decay Xi^0 --> Sigma^+ mu^- nu(bar)

The Xi^0 muon semi-leptonic decay has been observed for the first time with nine identified events using the KTeV beam line and detector at Fermilab. The decay is normalized to the Xi^0 beta decay mode and yields a value for the ratio of decay rates of $(1.8^{+0.7}_{-0.5}(stat.)\pm0.2(syst.))\times 10^{-2}$. This is in agreement with the SU(3) flavor symmetric quark model.

hep-ex

Final Results from the KTeV Experiment on the Decay KL -> pi0 gamma gamma

We report on a new measurement of the branching ratio B(KL->pi0 gamma gamma)using the KTeV detector. We reconstruct 1982 events with an estimated background of 608, that results in B(KL -> pi0 gamma gamma) = (1.29 +/- 0.03(stat) +/- 0.05(syst)) x 10**-6. We also measure the parameter, aV, which characterizes the strength of vector meson exchange terms in this decay. We find aV = -0.31 +/- 0.05(stat) +/- 0.07(syst). These results utilize the full KTeV data set collected from 1997 to 2000 and supersede earlier KTeV measurements of the branching ratio and aV.

hep-ex

Determination of the Parity of the Neutral Pion via the Four-Electron Decay

We present a new determination of the parity of the neutral pion via the double Dalitz decay pi^0 -> e+ e- e+ e-. Our sample, which consists of 30511 candidate decays, was collected from K_L -> pi0 pi0 pi0 decays in flight at the KTeV-E799 experiment at Fermi National Accelerator Laboratory. We confirm the negative pi^0 parity, and place a limit on scalar contributions to the pi^0 -> e+ e- e+ e- decay amplitude of less than 3.3% assuming CPT conservation. The pi^0 gamma* gamma* form factor is well described by a momentum-dependent model with a slope parameter fit to the final state phase space distribution. Additionally, we have measured the branching ratio of this mode to be B(pi^0 -> e+ e- e+ e-) = (3.26 +- 0.18) x 10^(-5).

hep-ex

Measurement of the Decay KL -> pi0 e+ e- gamma

We report on a new measurement of the branching ratio B(KL -> pi0 e+ e- gamma) using the KTeV detector. This analysis uses the full KTeV data set collected from 1997 to 2000. We reconstruct 139 events over a background of 14, which results in B(KL -> pi0 e+ e- gamma) = (1.62 +/- 0.14 (stat) +/- 0.09 (syst)) x 10^{-8}. This result supersedes the earlier KTeV measurement of this branching ratio.

hep-ex

Physics at the CLIC Multi-TeV Linear Collider

This report summarizes a study of the physics potential of the CLIC e+e- linear collider operating at centre-of-mass energies from 1 TeV to 5 TeV with luminosity of the order of 10^35 cm^-2 s^-1. First, the CLIC collider complex is surveyed, with emphasis on aspects related to its physics capabilities, particularly the luminosity and energy, and also possible polarization, γγand e-e- collisions. The next CLIC Test facility, CTF3, and its R&D programme are also reviewed. We then discuss aspects of experimentation at CLIC, including backgrounds and experimental conditions, and present a conceptual detector design used in the physics analyses, most of which use the nominal CLIC centre-of-mass energy of 3 TeV. CLIC contributions to Higgs physics could include completing the profile of a light Higgs boson by measuring rare decays and reconstructing the Higgs potential, or discovering one or more heavy Higgs bosons, or probing CP violation in the Higgs sector. Turning to physics beyond the Standard Model, CLIC might be able to complete the supersymmetric spectrum and make more precise measurements of sparticles detected previously at the LHC or a lower-energy linear e+e- collider: γγcollisions and polarization would be particularly useful for these tasks. CLIC would also have unique capabilities for probing other possible extensions of the Standard Model, such as theories with extra dimensions or new vector resonances, new contact interactions and models with strong WW scattering at high energies. In all the scenarios we have studied, CLIC would provide significant fundamental physics information beyond that available from the LHC and a lower-energy linear e+e- collider, as a result of its unique combination of high energy and experimental precision.

hep-ph

Measurements of the Branching Fractions and Decay Distributions for KL->πμνγand KL->πeνγ

We present measurements of R_Kl3rad = Gamma(KL->π\ellνγ; Egcm > 10 MeV)/Gamma(KL->π\ellν), where ell = mu or e, and Egcm is the photon energy in the kaon rest frame. These measurements are based on KL decays collected in 1997 by the KTeV (E832) experiment at Fermilab. With samples of 1385 KL->πμνγand 14221 KL->π\eνγcandidates, we find R_Km3rad = (0.530 +- 0.019)% and R_Ke3rad = (4.942 +- 0.062)%. We also examine distributions of photon energy and lepton-photon angle.

hep-ex

Les Houches Guidebook to Monte Carlo Generators for Hadron Collider Physics

Recently the collider physics community has seen significant advances in the formalisms and implementations of event generators. This review is a primer of the methods commonly used for the simulation of high energy physics events at particle colliders. We provide brief descriptions, references, and links to the specific computer codes which implement the methods. The aim is to provide an overview of the available tools, allowing the reader to ascertain which tool is best for a particular application, but also making clear the limitations of each tool.

hep-ph