arXiv ScienceSearch

arXiv subjects

Anne Sentenac

Publications and source records attributed to Anne Sentenac.

9 recordsLinked to original sources

Widefield two-photon random illumination microscopy (2P-RIM)

Biological and biomedical samples are routinely examined using focused two-photon (2P) fluorescence microscopy due to its intrinsic axial sectioning and reduced out-of-focus bleaching. However, 2P imaging often requires excitation intensities that can damage samples through ionization and radical formation. Additionally, the lateral resolution of 2P microscopy is lower compared to linear one-photon (1P) fluorescence microscopy. Widefield 2P microscopy, using cameras, holds promise for reducing photo-toxicity while maintaining high image acquisition rates. Widefield imaging trades the high power and short integration times of sequential single point scanning for the low power and extended integration times of parallel detection across millions of pixels. However, generating effective axial sectioning over arbitrarily large fields of view (FOVs) has remained a challenge. In this work, we introduce 2P Random Illumination Microscopy (2P-RIM), an easy-to-implement 2P widefield technique, that achieves low photo-damage, fast imaging, micrometric axial sectioning, and enhanced lateral resolution for arbitrarily large FOVs. By using widefield speckled illuminations in conjunction with an image standard deviation matching algorithm, 2P-RIM demonstrated multicolor imaging over FOVs greater than 200 um, lateral resolution 220 nm, axial sectioning 2 um, and peak excitation powers about 10 times lower than those used in focused laser scanning microscopy.

physics.optics

Quantitative phase microscopies: accuracy comparison

This article presents a thorough comparison of themain QPM techniques, focusing on their accuracy in terms of measurement precision and trueness. We focus on 8 techniques, namely digital holographic microscopy (DHM), cross-grating wavefront microscopy (CGM), which is based on QLSI (quadriwave lateral shearing interferometry), diffraction phase microscopy (DPM), differential phase-contrast (DPC) microscopy, phase-shifting interferometry (PSI) imaging, Fourier phase microscopy (FPM), spatial light interference microscopy (SLIM), and transport-of-intensity equation (TIE) imaging. For this purpose, we used a home-made numerical toolbox based on discrete dipole approximation (IF-DDA). This toolbox is designed to compute the electromagnetic field at the sample plane of a microscope, irrespective of the object's complexity or the illumination conditions. We upgraded this toolbox to enable it to model any type of QPM, and to take into account shot noise. In a nutshell, the results show that DHM and PSI are inherently free from artefacts and rather suffer from coherent noise; In CGM, DPC, DPM and TIE, there is a trade off between precision and trueness, which can be balanced by varying one experimental parameter; FPM and SLIM suffer from inherent artefacts that cannot be discarded experimentally in most cases, making the techniques not quantitative especially for large objects covering a large part of the field of view, such as eukaryotic cells.

physics.optics

Super-resolution capacity of variance-based stochastic fluorescence microscopy

Improving the resolution of fluorescence microscopy beyond the diffraction limit can be achievedby acquiring and processing multiple images of the sample under different illumination conditions.One of the simplest techniques, Random Illumination Microscopy (RIM), forms the super-resolvedimage from the variance of images obtained with random speckled illuminations. However, thevalidity of this process has not been fully theorized. In this work, we characterize mathematicallythe sample information contained in the variance of diffraction-limited speckled images as a functionof the statistical properties of the illuminations. We show that an unambiguous two-fold resolutiongain is obtained when the speckle correlation length coincides with the width of the observationpoint spread function. Last, we analyze the difference between the variance-based techniques usingrandom speckled illuminations (as in RIM) and those obtained using random fluorophore activation(as in Super-resolution Optical Fluctuation Imaging, SOFI).

physics.optics

Uniqueness of the Random Illumination Microscopy Variance Equation

Recently, it has been shown theoretically that fluorescence microscopy using random illuminations (RIM) yields a doubled lateral resolution and an improved optical sectioning. Moreover, an algorithm called algoRIM, based on variance matching, has been successfully validated on numerous biological applications. Here, we propose a proof of uniqueness of the RIM variance equation, which corresponds to a first theoretical validation of algoRIM.

physics.data-an

Inverse scattering for reflection intensity phase microscopy

Reflection phase imaging provides label-free, high-resolution characterization of biological samples, typically using interferometric-based techniques. Here, we investigate reflection phase microscopy from intensity-only measurements under diverse illumination. We evaluate the forward and inverse scattering model based on the first Born approximation for imaging scattering objects above a glass slide. Under this design, the measured field combines linear forward-scattering and height-dependent nonlinear back-scattering from the object that complicates object phase recovery. Using only the forward-scattering, we derive a linear inverse scattering model and evaluate this model's validity range in simulation and experiment using a standard reflection microscope modified with a programmable light source. Our method provides enhanced contrast of thin, weakly scattering samples that complement transmission techniques. This model provides a promising development for creating simplified intensity-based reflection quantitative phase imaging systems easily adoptable for biological research.

q-bio.QM

Approached vectorial model for Fano resonances in guided mode resonance gratings

We propose a self-consistent vectorial method, based on a Green's function technique, to describe the Fano resonances that appear in guided mode resonance gratings. The model provides intuitive expressions of the reflectivity and transmittivity matrices of the structure, involving coupling integrals between the modes of a planar reference structure and radiative modes. These expressions are used to derive a physical analysis in configurations where the effect of the incident polarization is not trivial. We provide numerical validations of our model. On a technical point of view, we show how the Green's tensor of our planar reference structure can be expressed as two scalar Green's functions, and how to deal with the singularity of the Green's tensor.

physics.optics

On the super-resolution capacity of imagers using unknown speckle illuminations

Speckle based imaging consists of forming a super-resolved reconstruction of an unknown sample from low-resolution images obtained under random inhomogeneous illuminations (speckles). In a blind context where the illuminations are unknown, we study the intrinsic capacity of speckle-based imagers to recover spatial frequencies outside the frequency support of the data, with minimal assumptions about the sample. We demonstrate that, under physically realistic conditions, the covariance of the data has a super-resolution power corresponding to the squared magnitude of the imager point spread function. This theoretical result is important for many practical imaging systems such as acoustic and electromagnetic tomographs, fluorescence and photoacoustic microscopes, or synthetic aperture radar imaging. A numerical validation is presented in the case of fluorescence microscopy.

physics.data-an

Joint reconstruction strategy for structured illumination microscopy with unknown illuminations

The blind structured illumination microscopy (SIM) strategy proposed in (Mudry et al., 1992) is fully re-founded in this paper, unveiling the central role of the sparsity of the illumination patterns in the mechanism that drives super-resolution in the method. A numerical analysis shows that the resolving power of the method can be further enhanced with optimized one-photon or two-photon speckle illuminations. A much improved numerical implementation is provided for the reconstruction problem under the image positivity constraint. This algorithm rests on a new preconditioned proximal iteration faster than existing solutions, paving the way to 3D and real-time 2D reconstruction

physics.data-an

Super-resolution photoacoustic fluctuation imaging with multiple speckle illumination

In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded-off for penetration depth. Here we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we show that the analysis of second-order fluctuations of the photoacoustic images combined with image deconvolution enables resolving optically absorbing structures beyond the acoustic diffraction limit. A resolution increase of almost a factor 2 is demonstrated experimentally. Our method introduces a new framework that could potentially lead to deep tissue photoacoustic imaging with sub-acoustic resolution.

physics.optics