arXiv ScienceSearch

arXiv subjects

Anindita Das

Publications and source records attributed to Anindita Das.

2 recordsLinked to original sources

The Natural Language Interaction Protocol and Standard for AI Agents

AI agents are increasingly being developed and deployed across organizations using heterogeneous agent-development frameworks, AI models, tool interfaces, protocols, and execution environments. To realize their potential social and business impact, these agents must be able to interoperate through a common communication protocol. The Natural Language Interaction Protocol (NLIP), developed by researchers and practitioners across companies and universities and standardized by Ecma International, addresses this need by defining a standards-based application-layer protocol for AI-agent interaction. NLIP provides a lightweight semantic message envelope that can be carried over existing transports such as HTTP/HTTPS, WebSocket, and AMQP, while allowing NLIP-aware agents and gateways to adapt between clients, agents, local context stores, ontologies, tools, enterprise services, and heterogeneous underlying protocols. This paper presents the motivation and design rationale of NLIP, its message model and transport bindings, security-by-design considerations, reference implementation, representative applications, adoption signals, and relationship to emerging agent protocols such as MCP and A2A.

cs.AI

Ag/Au coated inverted nanopyramids as flexible and wearable SERS substrates for biomolecular sensing

Surface enhanced Raman spectroscopy (SERS) has established itself as a promising tool in optical sensing technology. Efforts have been made to improve practicalities of the technology with regards to costs of production, stability, reproducibility, flexibility and robustness. Here, we demonstrate a method to fabricate Ag/Au bimetallic inverted nanopyramid (i-NPyr) and upright nanopyramid (u-NPyr) using a multi-step molding process on flexible plastics as SERS sensors for the ultrasensitive detection of haemoglobin at a very low concentration (down to nM). First, a Si i-NPyr master was created using electron beam lithography, then i-NPyr and u-NPyr structures were imprinted on flexible polymer substrates using nanoimprinting lithography, and last, Ag/Au coatings were coated on top of them. The SERS activity of the imprinted i-NPyr and u-NPyr substrates were evaluated using rhodamine 6G (Rh6G) as probe molecules. Enhancement factor (EF) values of 3.88 x 10^6 and 7.86 x 10^5 respectively for the iNPyr and u-NPyr substrates, and the i-NPyr SERS substrate was able to detect Rh6G at concentrations as low as 1pM. In addition, we investigated the stability and resilience of i-NPyr by thoroughly analysing signal performance under angled bending and delicate crumpling. Finally, a proof-of-concept application as a wearable i-NPyr SERS sensor was demonstrated by detecting the analyte in sweat excreted during running and walking. We believe that this extremely sensitive i-NPyr SERS substrate with dense electric field confinement around hotspots (confirmed using computational simulations), as well as its good stability, durability, and low production cost, may enable in-situ measurement of analytes in wearable technologies.

physics.app-ph