arXiv Science⌕ Search

arXiv subjects

Aneri Bhatt

Publications and source records attributed to Aneri Bhatt.

3 recordsLinked to original sources

Multi-echo AxCaliberSMT: Mapping effective axon radius from restricted diffusion and radius-dependent intra-axonal T2

Diffusion-based axon radius r mapping preferentially detects larger axons since restricted-diffusion contrast scales with r^4, limiting sensitivity to thin axons dominating human white matter (WM). Surface relaxation provides complementary sensitivity through an intra-axonal R2 proportional to 1/r. We combined these mechanisms to broaden the dynamic range of radius estimations. Multi-echo AxCaliberSMT (ME-AxCaliberSMT) models spherical-mean diffusion-relaxation signals using cylinder-restricted diffusion and histologically calibrated surface relaxation. Simulations compared its accuracy and robustness with AxCaliberSMT and a diffusion-filtered R2 model, which infer radius solely from restricted diffusion and intra-axonal R2, respectively. Five healthy adults were scanned on Connectome 2.0 (C2; 500 mT/m), and four also on Cima.X (200 mT/m), using multiple b-values at two diffusion times, each paired with a different echo time. Diffusion and relaxation contrasts were comparable at a protocol-dependent transition radius (C2: 1.42 um; Cima.X: 1.85 um). Below this threshold, relaxation dominated, yielding effective r estimates approximately / in most WM. At SNR 40, ME-AxCaliberSMT achieved normalised bias $\pm$6%, whereas AxCaliberSMT overestimated small radii. ME-AxCaliberSMT was less sensitive to tested calibration errors than the R2 model. In vivo, ME-AxCaliberSMT bundle radii on C2 were 0.30-0.51 um (AxCaliberSMT: 1.03-1.38 um) and followed the histological pattern along the corpus callosum. ME-AxCaliberSMT estimates correlated between scanners (mean Pearson correlation 0.73), unlike AxCaliberSMT (-0.23), although Cima.X values were systematically higher. Combining diffusion and relaxation extends axon radius mapping from large to small axons. Translation to a commercial high-gradient scanner reproduced bundle-wise patterns, although absolute estimates remained protocol-dependent.

physics.med-ph↗

MWF-MIMOSA for efficient simultaneous relaxometry and myelin water fraction mapping

Quantitative magnetic resonance imaging (qMRI) provides improved sensitivity and specificity to tissue composition and pathological alterations compared with conventional contrast-weighted imaging. Among various qMRI biomarkers, myelin water imaging is of particular interest because myelin plays a central role in brain function and its alteration is closely associated with many neurological diseases. However, conventional myelin water fraction (MWF) mapping techniques are often limited by long scan times, low spatial resolution, reduced signal-to-noise ratio (SNR), and high specific absorption rate (SAR). Here, we propose MWF-MIMOSA for efficient simultaneous T1, T2, T2* mapping, magnetic susceptibility source separation, and MWF estimation. To achieve this, multi-contrast and multi-slice zero-shot self-supervised learning (MZS-SSL) was used to jointly reconstruct whole-brain complex-valued images. To improve computational efficiency of the parameter estimation step, a multilayer perceptron (MLP) was trained within the GACELLE GPU-accelerated parameter estimation framework to circumvent the computationally intensive Bloch simulation process, resulting in a >100-fold computational speed-up in MWF estimation. Numerical simulations were performed to evaluate the accuracy and precision of MWF-MIMOSA, and in-vivo results further demonstrated its robustness. Comparison with existing myelin water imaging methods showed that MWF-MIMOSA is highly correlated with established approaches, while providing complementary quantitative parameter maps at higher spatial resolution and with shorter scan times. Notably, simultaneous multi-parametric mapping was achieved in 5 min at 1 mm isotropic resolution, and in 10 min at 0.7 mm isotropic resolution. These results demonstrate the potential of MWF-MIMOSA for fast, high-resolution simultaneous relaxometry and myelin water imaging.

physics.med-ph↗

Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner

Biophysical diffusion MRI models like Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities, neurite fraction, and exchange time. However, NEXI's multi-shell, multi-diffusion-time requirements cause prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, cutting scan time from 27 to 14 minutes. Validated in vivo in seven healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cram'er-Rao Lower Bound (CRLB) theoretical optimum, and two heuristics ("Mid-Range" and "Corner"). It robustly reproduced parameter estimates and maintained test-retest reproducibility. Remarkably, the XAI selection converged to the CRLB optimum. This validates XAI's optimality while highlighting its main advantage: achieving gold-standard optimization without complex analytical Jacobians, making it easily adaptable to numerical models or complex noise where CRLB is intractable. Furthermore, XAI showed superior in vivo robustness over heuristics: "Mid-Range" sampling yielded biased exchange time estimates from insufficient temporal diversity, while "Corner" sampling gave unstable intra-neurite diffusivity estimates (5-fold higher CV) due to noise sensitivity. Ultimately, this robust 14-minute protocol accelerates exchange-sensitive microstructural mapping, establishing a model-agnostic optimization framework adaptable to future ultra-high gradient systems and existing clinical scanners.

physics.med-ph↗