Andreas Renner

Publications and source records attributed to Andreas Renner.

2 recordsLinked to original sources

Evaluation of attenuation-based simulated X-ray images for image-guided radiotherapy

In image-guided radiation therapy (IGRT), in-room X-rays are often used for patient positioning and monitoring, however, usually default imaging settings are utilized for each indication. Obtaining patient-specific imaging settings before treatment is achievable using simulated X-rays, which can facilitate IGRT workflow optimization. This study evaluated the image quality of simulated X-rays for thoracic, cranial and pelvic regions. Simulated X-rays were created from computed tomography (CT) scans with indication-specific default settings using a pre-release pilot software, which mimics the geometry of the room-mounted ExacTrac Dynamic (ETD) system (Brainlab SE, Germany). The basis of this algorithm was the Beer-Lambert law. Linear attenuation coefficients were approximated from the CT hounsfield units, while incident intensities were defined by flood images. CT scans were included from three anthropomorphic phantoms and 57 patients (13 lung, 20 glioblastoma, 24 prostate). For evaluation, real X-rays were used as ground truth. Three image quality metrics - Structural Similarity Index (SSIM), Normalized Cross Correlation (NCC), Normalized Mean Absolute Error (NMAE) - complemented by histogram and intensity profile comparisons were used for evaluation. SSIMs for phantom and patient average were 0.87 and 0.80 for the thoracic, 0.94 and 0.88 for the cranial and 0.85 and 0.79 for the pelvic region. Corresponding NCCs yielded values of 0.99 and 0.89, 0.99 and 0.99 and 0.99 and 0.60. NMAEs were 4.1% and 10.7% (lung), 2.6% and 3.2% (brain) and 2.6% and 4.0% (pelvis). Histograms of real X-rays and simulated X-rays (sX-rays) were slightly shifted and showed differences at the background pixel value. Intensity profiles exhibited similar trends with some differences in absolute values. The investigated simulated X-rays demonstrated promising quality for individualized IGRT treatment preparation.

physics.med-ph↗

Realistic 3D printed imaging tumor phantoms for validation of image processing algorithms

Medical imaging phantoms are widely used for validation and verification of imaging systems and algorithms in surgical guidance and radiation oncology procedures. Especially, for the performance evaluation of new algorithms in the field of medical imaging, manufactured phantoms need to replicate specific properties of the human body, e.g., tissue morphology and radiological properties. Additive manufacturing (AM) technology provides an inexpensive opportunity for accurate anatomical replication with customization capabilities. In this study, we proposed a simple and cheap protocol to manufacture realistic tumor phantoms based on the filament 3D printing technology. Tumor phantoms with both homogenous and heterogenous radiodensity were fabricated. The radiodensity similarity between the printed tumor models and real tumor data from CT images of lung cancer patients was evaluated. Additionally, it was investigated whether a heterogeneity in the 3D printed tumor phantoms as observed in the tumor patient data had an influence on the validation of image registration algorithms. A density range between -217 to 226 HUs was achieved for 3D printed phantoms; this range of radiation attenuation is also observed in the human lung tumor tissue. The resulted HU range could serve as a lookup-table for researchers and phantom manufactures to create realistic CT tumor phantoms with the desired range of radiodensities. The 3D printed tumor phantoms also precisely replicated real lung tumor patient data regarding morphology and could also include life-like heterogeneity of the radiodensity inside the tumor models. An influence of the heterogeneity on accuracy and robustness of the image registration algorithms was not found.

physics.med-ph↗