arXiv ScienceSearch

arXiv subjects

Andrea Bassi

Publications and source records attributed to Andrea Bassi.

9 recordsLinked to original sources

STEPIC: High-Speed Imaging via Spatio-Temporal Encoding in Photonic Integrated Circuits

High-speed imaging of cells in flow is essential for probing cellular heterogeneity in large populations. Existing imaging approaches based on single-pixel detection and spatio-temporal encoding provide exceptional speed, but typically rely on bulky free-space optics, long dispersive elements, and are prone to alignment instabilities. Here, we introduce STEPIC Microscopy, the first fully integrated on-chip system for high-speed imaging via spatio-temporal encoding in photonic integrated circuits. Our platform leverages waveguides, splitters, fiber delay-lines, and 3D optical remappers to encode spatial information into the temporal domain, enabling robust image reconstruction of cells flowing through microchannels. The monolithic architecture provides a compact and robust platform for high-throughput bioimaging, enabling scalable and practical implementations of ultrafast imaging systems.

physics.optics

Iterative approach for high-quality binary intensity hologram generation in augmented reality applications

Binary amplitude spatial light modulators, such as digital micromirror devices (DMDs), are increasingly relevant for computer generated holography due to their high refresh rates, low cost, and due to the emergence of subwavelength pixel architectures. However, the binary constraint limits the reconstruction quality, as conventional approaches rely on a binarization applied as a final step after hologram computation which leads to reduced efficiency and contrast. We introduce an iterative estimation approach for the generation of off axis binary amplitude holograms, in which the binarization constraint is applied at each iteration. We validate the approach through numerical simulations and experimental reconstruction using a DMD based optical setup. Quantitative and qualitative comparisons with random superposition and Gerchberg Saxton methods demonstrate significant improvements in image contrast, light efficiency, and reconstruction fidelity, with comparable computational cost. The proposed method provides a practical route toward high quality CGH using binary modulators and supports emerging applications requiring high speed and high resolution holographic projection.

physics.optics

Zero-Order Diffraction Suppression in Full Field-of-View Computer Generated Holography: A Camera In the Loop Interferometric Approach

We introduce a novel interferometric approach for suppressing zero-order diffraction (ZOD) in phase-only computer-generated holography. The technique relies on the destructive interference between the zeroth-order light and a suppression beam in a plane optically conjugated to the spatial light modulator (SLM). A camera-in-the-loop (CITL) calibration procedure retrieves the optimal pixel-wise phase map that cancels out the ZOD component with high precision, while preserving the full modulation depth of the SLM. Experimental demonstrations on point-cloud and 2D/3D holograms achieve up to 99% suppression of the ZOD intensity, without loss of image quality or field of view. Once calibrated, the correction can be applied to any hologram without recomputation, enabling real-time operation and robust performance over time. This method removes a long-standing barrier to the practical deployment of full-field holography, facilitating the development of compact, high-fidelity holographic engines for augmented and mixed reality displays.

physics.optics

Full-aperture extended-depth oblique plane microscopy through dynamic remote focusing

Oblique plane microscopy is a method enabling light-sheet fluorescence imaging through a single microscope objective lens by focusing on a tilted plane within the sample. To focus the fluorescence emitted by the oblique plane on a camera, the light is imaged through a pair of remote objective lenses, facing each other at an angle. The aperture mismatch resulting from this configuration limits the effective numerical aperture of the system, reducing image resolution and signal intensity. This manuscript introduces an alternative method to capture the oblique plane on the camera. Instead of relying on angled objective lenses, an electrically tunable lens is employed. This lens adjusts the focal plane of the microscope synchronously with the rolling shutter of a scientific CMOS camera. In this configuration the entire aperture of the objective is effectively employed, increasing the resolution of the system. Moreover, a variety of objective lenses can be employed, enabling the acquisition of wider axial fields of view compared to conventional oblique plane microscopy.

physics.optics

Aberration measurement and correction on a large field of view in fluorescence microscopy

The aberrations induced by the sample and/or by the sample holder limit the resolution of optical microscopes. Wavefront correction can be achieved using a deformable mirror with wavefront sensorless optimization algorithms but, despite the complexity of these systems, the level of correction is often limited to a small area in the field of view of the microscope. In this work, we present a plug and play module for aberration measurement and correction. The wavefront correction is performed through direct wavefront reconstruction using the spinning-pupil aberration measurement and controlling a deformable lens in closed loop. The lens corrects the aberrations in the center of the field of view, leaving residual aberrations at the margins, that are removed by anisoplanatic deconvolution. We present experimental results obtained in fluorescence microscopy, with a wide field and a light sheet fluorescence microscope. These results indicate that detection and correction over the full field of view can be achieved with a compact transmissive module placed in the detection path of the fluorescence microscope.

physics.optics

Spinning Pupil Aberration Measurement for anisoplanatic deconvolution

The aberrations in an optical microscope are commonly measured and corrected at one location in the field of view, within the so-called isoplanatic patch. Full-field correction is desirable for high-resolution imaging of large specimens. Here we present a novel wavefront detector, based on pupil sampling with sub-apertures, which measures the aberrated wavefront phase at each position of the specimen. Based on this measurement, we propose a region-wise deconvolution that provides an anisoplanatic reconstruction of the sample image. Our results indicate that the measurement and correction of the aberrations can be performed in a wide-field fluorescence microscope over its entire field of view.

physics.optics

Beyond multi-view deconvolution for inherently-aligned fluorescence tomography

In multi-view fluorescence microscopy, each angular acquisition needs to be aligned with care to obtain an optimal volumetric reconstruction. Here, instead, we propose a neat protocol based on auto-correlation inversion, that leads directly to the formation of inherently aligned tomographies. Our method generates sharp reconstructions, with the same accuracy reachable after sub-pixel alignment but with improved point-spread-function. The procedure can be performed simultaneously with deconvolution further increasing the reconstruction resolution.

eess.IV

QUAREP-LiMi: A community-driven initiative to establish guidelines for quality assessment and reproducibility for instruments and images in light microscopy

In April 2020, the QUality Assessment and REProducibility for Instruments and Images in Light Microscopy (QUAREP-LiMi) initiative was formed. This initiative comprises imaging scientists from academia and industry who share a common interest in achieving a better understanding of the performance and limitations of microscopes and improved quality control (QC) in light microscopy. The ultimate goal of the QUAREP-LiMi initiative is to establish a set of common QC standards, guidelines, metadata models, and tools, including detailed protocols, with the ultimate aim of improving reproducible advances in scientific research. This White Paper 1) summarizes the major obstacles identified in the field that motivated the launch of the QUAREP-LiMi initiative; 2) identifies the urgent need to address these obstacles in a grassroots manner, through a community of stakeholders including, researchers, imaging scientists, bioimage analysts, bioimage informatics developers, corporate partners, funding agencies, standards organizations, scientific publishers, and observers of such; 3) outlines the current actions of the QUAREP-LiMi initiative, and 4) proposes future steps that can be taken to improve the dissemination and acceptance of the proposed guidelines to manage QC. To summarize, the principal goal of the QUAREP-LiMi initiative is to improve the overall quality and reproducibility of light microscope image data by introducing broadly accepted standard practices and accurately captured image data metrics.

q-bio.OT

Deconvolved Image Restoration from Autocorrelations

Recovering a signal from auto-correlations or, equivalently, retrieving the phase linked to a given Fourier modulus, is a wide-spread problem in imaging. This problem has been tackled in a number of experimental situations, from optical microscopy to adaptive astronomy, making use of assumptions based on constraints and prior information about the recovered object. In a similar fashion, deconvolution is another common problem in imaging, in particular within the optical community, allowing high-resolution reconstruction of blurred images. Here we address the mixed problem of performing the auto-correlation inversion while, at the same time, deconvolving its current estimation. To this end, we propose an I-divergence optimization, driving our formalism into a widely used iterative scheme, inspired by Bayesian-based approaches. We demonstrate the method recovering the signal from blurred auto-correlations, further analysing the cases of blurred objects and band-limited Fourier measurements.

eess.IV