Publications and source records attributed to Alyasaa Anas.

2 recordsLinked to original sources

NIMARC-MRI: Abdominal HASTE Dataset and a Baseline U-Net Exposing the Synthetic-to-Real Gap in Low-Resource Motion Correction

Respiratory motion degrades abdominal T2 HASTE MRI in low- and middle-income countries where vendor motion-correction licenses are unavailable and failed scans are deleted during routine PACS cleanup, precluding supervised training. To address this, we introduce NIMARC-MRI, the first public abdominal MRI dataset from West Africa, comprising 139 clean HASTE, 25 native motion-degraded HASTE, and 79 paired HASTE-TSE TRIGGER acquisitions from a Nigerian centre operating 1.5 T Siemens scanner without integrated motion-correction licenses. A 2D U-Net with 7.7 million parameters was trained on 3D-consistent synthetic respiratory motion necessitated by local infrastructure reality and validated via a three-tier strategy: held-out synthetic data, blinded radiologist Likert scoring on native real motion, and cross-sequence TRIGGER generalisation. On synthetic test data the model achieved SSIM 0.863 +/- 0.042 and PSNR 30.06 +/- 1.80 dB. On native real motion, however, blinded radiologist and radiographer scores showed no significant improvement (mean Likert 4.06 +/- 0.55 original versus 4.04 +/- 0.61 corrected, P = 0.914), with 28% of cases rated worse after correction. Cross-sequence TRIGGER evaluation showed modest SSIM improvement (0.404 +/- 0.073 versus 0.334 +/- 0.055, P < 0.001) without radiologist-perceived gain. These findings demonstrate that conservative synthetic motion fails to capture clinical motion severity, exposing a reproducible synthetic-to-real gap. NIMARC-MRI is released on Zenodo (https://doi.org) under a controlled data-use agreement requiring citation. Sequence metadata and a sample subset are publicly accessible to facilitate discovery, while patient-level data remain restricted to approved collaborators. The aim is to establish a reproducible baseline for motion correction in resource-constrained settings.

eess.IV

From Manuals to Maintenance: Fine-Tuning MedGemma for Multi-Modal Imaging System Support in Low-Resource Settings

Imaging device downtime is a major barrier to healthcare delivery in low- and middle-income countries (LMICs), often driven by limited access to specialized biomedical engineering support. We present a multi-modality medical equipment maintenance question-answering (QA) framework and demonstrate the fine-tuning of a medical foundation model for specialized technical troubleshooting tasks. Guided by a multi-country survey across nine LMICs, we curated technical manuals from MRI and ultrasound systems to generate the INGENZI_DatasetV1, containing 10,294 high-quality, filtered QA-context pairs. Using QLoRA-based parameter-efficient fine-tuning, we adapted the MedGemma-4b-it model to interpret system error logs and generate step-by-step equipment repair instructions. Compared to the baseline model, the fine-tuned system achieved substantial improvements across metrics, including F1 score (0.22 to 0.38), ROUGE-2 (0.18 to 0.41), and BERTScore F1 (0.86 to 0.91). These metric gains demonstrate that the model generates significantly more precise and procedurally accurate technical responses to new troubleshooting queries. This work establishes a reliable foundation for AI-assisted diagnostic and maintenance tools in resource-constrained settings.

cs.AI