arXiv Science⌕ Search

arXiv subjects

Ali Vosoughi

Publications and source records attributed to Ali Vosoughi.

25 records · Page 2Linked to original sources

MISAR: A Multimodal Instructional System with Augmented Reality

Augmented reality (AR) requires the seamless integration of visual, auditory, and linguistic channels for optimized human-computer interaction. While auditory and visual inputs facilitate real-time and contextual user guidance, the potential of large language models (LLMs) in this landscape remains largely untapped. Our study introduces an innovative method harnessing LLMs to assimilate information from visual, auditory, and contextual modalities. Focusing on the unique challenge of task performance quantification in AR, we utilize egocentric video, speech, and context analysis. The integration of LLMs facilitates enhanced state estimation, marking a step towards more adaptive AR systems. Code, dataset, and demo will be available at https://github.com/nguyennm1024/misar.

cs.CL↗

Separating Invisible Sounds Toward Universal Audiovisual Scene-Aware Sound Separation

The audio-visual sound separation field assumes visible sources in videos, but this excludes invisible sounds beyond the camera's view. Current methods struggle with such sounds lacking visible cues. This paper introduces a novel "Audio-Visual Scene-Aware Separation" (AVSA-Sep) framework. It includes a semantic parser for visible and invisible sounds and a separator for scene-informed separation. AVSA-Sep successfully separates both sound types, with joint training and cross-modal alignment enhancing effectiveness.

cs.CV↗

Unveiling Cross Modality Bias in Visual Question Answering: A Causal View with Possible Worlds VQA

To increase the generalization capability of VQA systems, many recent studies have tried to de-bias spurious language or vision associations that shortcut the question or image to the answer. Despite these efforts, the literature fails to address the confounding effect of vision and language simultaneously. As a result, when they reduce bias learned from one modality, they usually increase bias from the other. In this paper, we first model a confounding effect that causes language and vision bias simultaneously, then propose a counterfactual inference to remove the influence of this effect. The model trained in this strategy can concurrently and efficiently reduce vision and language bias. To the best of our knowledge, this is the first work to reduce biases resulting from confounding effects of vision and language in VQA, leveraging causal explain-away relations. We accompany our method with an explain-away strategy, pushing the accuracy of the questions with numerical answers results compared to existing methods that have been an open problem. The proposed method outperforms the state-of-the-art methods in VQA-CP v2 datasets.

cs.CV↗

Cross Modal Global Local Representation Learning from Radiology Reports and X-Ray Chest Images

Deep learning models can be applied successfully in real-work problems; however, training most of these models requires massive data. Recent methods use language and vision, but unfortunately, they rely on datasets that are not usually publicly available. Here we pave the way for further research in the multimodal language-vision domain for radiology. In this paper, we train a representation learning method that uses local and global representations of the language and vision through an attention mechanism and based on the publicly available Indiana University Radiology Report (IU-RR) dataset. Furthermore, we use the learned representations to diagnose five lung pathologies: atelectasis, cardiomegaly, edema, pleural effusion, and consolidation. Finally, we use both supervised and zero-shot classifications to extensively analyze the performance of the representation learning on the IU-RR dataset. Average Area Under the Curve (AUC) is used to evaluate the accuracy of the classifiers for classifying the five lung pathologies. The average AUC for classifying the five lung pathologies on the IU-RR test set ranged from 0.85 to 0.87 using the different training datasets, namely CheXpert and CheXphoto. These results compare favorably to other studies using UI-RR. Extensive experiments confirm consistent results for classifying lung pathologies using the multimodal global local representations of language and vision information.

cs.CV↗

Investigation of large-scale extended Granger causality (lsXGC) on synthetic functional MRI data

It is a challenging research endeavor to infer causal relationships in multivariate observational time-series. Such data may be represented by graphs, where nodes represent time-series, and edges directed causal influence scores between them. If the number of nodes exceeds the number of temporal observations, conventional methods, such as standard Granger causality, are of limited value, because estimating free parameters of time-series predictors lead to underdetermined problems. A typical example for this situation is functional Magnetic Resonance Imaging (fMRI), where the number of nodal observations is large, usually ranging from $10^2$ to $10^5$ time-series, while the number of temporal observations is low, usually less than $10^3$. Hence, innovative approaches are required to address the challenges arising from such data sets. Recently, we have proposed the large-scale Extended Granger Causality (lsXGC) algorithm, which is based on augmenting a dimensionality-reduced representation of the system's state-space by supplementing data from the conditional source time-series taken from the original input space. Here, we apply lsXGC on synthetic fMRI data with known ground truth and compare its performance to state-of-the-art methods by leveraging the benefits of information-theoretic approaches. Our results suggest that the proposed lsXGC method significantly outperforms existing methods, both in diagnostic accuracy with Area Under the Receiver Operating Characteristic (AUROC = $0.849$ vs.~$[0.727, 0.762]$ for competing methods, $p<\!10^{-8}$), and computation time ($3.4$ sec vs.~[$9.7$, $4.8 \times 10^3$] sec for competing methods) benchmarks, demonstrating the potential of lsXGC for analyzing large-scale networks in neuroimaging studies of the human brain.

cs.IT↗

Re-defining Radiology Quality Assurance (QA) -- Artificial Intelligence (AI)-Based QA by Restricted Investigation of Unequal Scores (AQUARIUS)

There is an urgent need for streamlining radiology Quality Assurance (QA) programs to make them better and faster. Here, we present a novel approach, Artificial Intelligence (AI)-Based QUality Assurance by Restricted Investigation of Unequal Scores (AQUARIUS), for re-defining radiology QA, which reduces human effort by up to several orders of magnitude over existing approaches. AQUARIUS typically includes automatic comparison of AI-based image analysis with natural language processing (NLP) on radiology reports. Only the usually small subset of cases with discordant reads is subsequently reviewed by human experts. To demonstrate the clinical applicability of AQUARIUS, we performed a clinical QA study on Intracranial Hemorrhage (ICH) detection in 1936 head CT scans from a large academic hospital. Immediately following image acquisition, scans were automatically analyzed for ICH using a commercially available software (Aidoc, Tel Aviv, Israel). Cases rated positive for ICH by AI (ICH-AI+) were automatically flagged in radiologists' reading worklists, where flagging was randomly switched off with probability 50%. Using AQUARIUS with NLP on final radiology reports and targeted expert neuroradiology review of only 29 discordantly classified cases reduced the human QA effort by 98.5%, where we found a total of six non-reported true ICH+ cases, with radiologists' missed ICH detection rates of 0.52% and 2.5% for flagged and non-flagged cases, respectively. We conclude that AQUARIUS, by combining AI-based image analysis with NLP-based pre-selection of cases for targeted human expert review, can efficiently identify missed findings in radiology studies and significantly expedite radiology QA programs in a hybrid human-machine interoperability approach.

cs.HC↗

Voltage regulator assisted lightweight countermeasure against fault injection attacks

The impeccable design of sensitive and cryptographic circuits (CC) against fault injection attacks is essential for modern data storage, communication, and computation systems that are susceptible to fault injection attacks. The robustness of a CC against voltage glitch attacks increases with an on-chip voltage regulator that considers the impact of topology and component selection on the fault injection robustness. With an emphasis on increasing the number of phases in a multiphase voltage regulator and component selection, an on-chip voltage regulator with multiphase configuration and an optimal operating point is proposed as a lightweight countermeasure to minimize injected glitches. Furthermore, an infective countermeasure is added to the on-chip multiphase voltage regulator that contaminates the computation of the cryptographic algorithm when a voltage glitch reaches to the CC. By increasing the number of phases from 1 to 16, the confrontation with fault attacks increases by 52.45%, which is equal to 91.82% if the number of phases increases to 32. Using the infective countermeasure for fault resiliency, the security-enhanced CC provides a robust and resilient solution against fault attacks that improve the security and availability of the device.

cs.CR↗