arXiv ScienceSearch

arXiv subjects

Alexandra Mitchell

Publications and source records attributed to Alexandra Mitchell.

4 recordsLinked to original sources

Multi-scale optimal control for Einstein Telescope active seismic isolation

We present a multi-scale optimal control framework for active seismic isolation in the Einstein Telescope, a third-generation gravitational-wave observatory. Our approach jointly optimizes feedback and blending filters in a cross-coupled opto-mechanical system using a unified cost function based on the "acausal optimum," which quantifies sensor signal-to-noise ratios across frequencies. This method enables efficient re-optimization under varying sensor configurations and environmental conditions. We apply the framework to two candidate sensing systems using their modeled sensitivity: OmniSens-a six-degree-of-freedom inertial isolation system-and BRS-T360, which combines Beam Rotation Sensor (BRS) as an inertial tilt sensor with T360 as a horizontal seismometer. We demonstrate superior low-frequency isolation with OmniSens, reducing platform motion by up to two orders of magnitude near the microseism. The framework allows for ready optimization and projection of sensor noise to metrics relevant to the performance of the instrument, aiding the design of the Einstein Telescope.

physics.ins-det

Integration of high-performance compact interferometric sensors in a suspended interferometer

Homodyne Quadrature Interferometers (HoQIs) are compact, low noise and high dynamic range displacement sensors designed for use in gravitational wave observatories. Their lower noise compared to the displacement sensors used at present makes them valuable for improving the seismic isolation in current and future detectors. This paper outlines the progression of this sensor from initial production and benchtop tests to in-vacuum static performance and installation in a gravitational wave detector prototype facility. A detailed design description is outlined, including the full signal and optical chain required for implementation in detectors. The measured in-vacuum static performance indicates a noise floor of $3-4\times10^{-13}m/\sqrt{\rm{Hz}}$ at 10Hz. Three HoQIs were installed on the beamsplitter suspension at the AEI 10m prototype. They measured motion of the intermediate mass across the entire bandwidth measured and showed minimal non-linearities and a good robustness to motion in unmeasured degrees of freedom, both important for practical use in dynamic systems such as seismic isolation.

physics.ins-det

Design and sensitivity of a 6-axis seismometer for gravitational wave observatories

We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localisation of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force.

physics.ins-det

Active platform stabilisation with a 6D seismometer

We demonstrate the control scheme of an active platform with a six degree of freedom (6D) seismometer. The inertial sensor simultaneously measures translational and tilt degrees of freedom of the platform and does not require any additional sensors for the stabilisation. We show that a feedforward cancellation scheme can efficiently decouple tilt-to-horizontal coupling of the seismometer in the digital control scheme. We stabilise the platform in the frequency band from 250 mHz up to 10 Hz in the horizontal degrees of freedom and achieve a suppression factor of 100 around 1 Hz. Further suppression of ground vibrations was limited by the non-linear response of the piezo actuators of the platform and by its limited range (5 {\mu}m). In this paper we discuss the 6D seismometer, its control scheme, and the limitations of the test bed.

astro-ph.IM