arXiv ScienceSearch

arXiv subjects

Alexander Rack

Publications and source records attributed to Alexander Rack.

16 recordsLinked to original sources

Full-field fluorescence computed tomography (F3CT) using a calibrated virtual cone-beam pinhole geometry

We present F3CT, a synchrotron-based hyperspectral full-field fluorescence computed tomography technique that avoids raster scanning by combining a pinhole aperture with an energy-resolving 2D detector. A virtual cone-beam model and two-stage calibration-reconstruction workflow enable 3D elemental mapping under full-field illumination. The method is demonstrated on biological and geological specimens, resolving silver-stain distributions in zebrafish tissue and high-energy fluorescence signatures in rock cores. Phase-contrast tomograms acquired sequentially under the same experimental geometry provide co-registered structural context. F3CT provides a high-throughput route to 3D XRF imaging and establishes a foundation for correlated structural and chemical tomography, with potential for future in-situ and operando implementations.

physics.ins-det

Drill-bit-inspired dynamic focal fields for augmented laser materials processing

Laser manufacturing has advanced through increasingly precise control of power, pulse duration, repetition rate and scan trajectory, yet the spatial intensity profile of the beam is still usually fixed during light-matter interaction. This constraint limits how energy can be delivered to matter, particularly in processes where melt flow, material removal and surface morphology evolve on comparable time and length scales. Here we introduce drill-bit-inspired laser beams that convert the focal intensity distribution from a passive, static spot into an active, programmable processing tool. By combining cylindrical vector beams with rotational vectorial polarization filtering, we create a near diffraction limited two lobe Hermite-Gaussian focus that continuously spins about the propagation axis and can be reconfigured on demand. We establish two operating regimes, dynamic beam spinning and instantaneous beam-profile shifting, and derive closed-form descriptions of the accumulated fluence and effective pulse number governed by the along-scan pitch l = u/f, where u is the scan speed and f is the spin frequency. Across continuous-wave and ultrashort-pulse regimes, this dynamic energy deposition enables low-power metal machining with drilling efficiencies about four times higher than static Gaussian, enhances convective melt flow, promotes pore resorption and reduces retained porosity in keyhole welding, as visualized by in situ X-ray imaging, and turns simple linear scans into programmable surface textures. These results show that dynamic focal-profile control can extend laser processing beyond static beam shaping, opening a broadly applicable route to programmable energy deposition in manufacturing.

physics.optics

Cavitation by phase shift of focused shock waves inside a droplet

Localized cavitation in liquids and soft tissues, typically initiated by the rarefaction phase of high-amplitude ultrasound waves, is leveraged in several biomedical applications such as ablation techniques and drug delivery with vaporizing agents. However, safety considerations aimed at avoiding unwanted bubble activity outside the targeted region pose a limit to the maximum allowed peak rarefaction pressure, which on the other hand can hinder the therapeutic efficacy of these techniques. This study shows that a purely compressive shock wave can generate localized, negative pressure and initiate cavitation inside a sub-millimetric perfluorohexane droplet, without requiring any externally applied rarefaction wave. The Gouy phase shift is identified as the physical mechanism responsible for the conversion of positive pressure into tension during shock focusing, and its occurrence is demonstrated through numerical simulations and direct experimental measurements. Comparison of the regions affected by cavitation, visualized \emph{in-situ} by means of high-speed x-ray phase-contrast imaging, with prediction from Classical Nucleation Theory suggests homogeneous nucleation as the underlying mechanism behind bubble formation. The presented findings offer valuable insights into the physics of shock wave propagation which can inspire the development of novel acoustic driving strategies for cavitation generation, facilitating the reduction of negative pressures outside the target region and improving the safety and precision of biomedical treatments.

physics.flu-dyn

Shape modes and jet formation on ultrasound-driven wall-attached bubbles

Understanding how substrate-attached bubbles respond to ultrasound is important for applications from industrial cleaning to biomedical therapy. Under ultrasonic excitation, bubbles can deform through Faraday instability and periodically emit high-speed jets. Although this behavior is increasingly well understood for free bubbles, the dynamics of wall-attached bubbles remain largely unexplored. In particular, the three-dimensional selection and evolution of non-spherical modes and their relation to jetting have not been resolved. We investigate micrometric air bubbles in contact with a rigid substrate and driven by ultrasound, using a dual-view imaging setup combining top-view bright-field microscopy with side-view phase-contrast X-ray imaging. This approach reveals a stepwise evolution of bubble shape through four regimes: spherical oscillations, harmonic axisymmetric meniscus waves, half-harmonic axisymmetric Faraday waves, and the superposition of half-harmonic sectoral Faraday waves. This contrasts with free bubbles, which jump directly to their final Faraday pattern at instability onset. For the chosen substrate, the observed shape-mode spectrum is degenerate and spans a continuous range of mode degrees, consistent with theoretical predictions based on kinematic arguments. Free bubbles, although also degenerate, remain limited to discrete spherical harmonics. Measured ultrasound pressure thresholds for Faraday instability agree with classical interface-stability theory modified for a rigid boundary. Complementary 3D boundary-element simulations reproduce the observed shape evolution. Finally, we identify the acceleration threshold for cyclic jetting: unlike free bubbles, wall-attached bubbles always jet from the side not constrained by the substrate.

physics.flu-dyn

Development towards high-resolution kHz-speed rotation-free volumetric imaging

X-ray multi-projection imaging (XMPI) provides rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the shear forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per second and 8 $\mu$m resolution per projection using the full dynamical range of our detectors. Since XMPI is a method under development, we also provide different tests for the instrumentation of up to 3000 frames per second. As the flux of X-ray sources grows globally, XMPI is a promising technique for current and future X-ray imaging instruments.

physics.ins-det

Ultrafast Radiographic Imaging and Tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes, fundamental to nuclear fusion energy, advanced manufacturing, green transportation and others, often involve one mole or more atoms, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: a.) Detectors; b.) U-RadIT modalities; c.) Data and algorithms; and d.) Applications. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification, and U-RadIT optimization.

physics.ins-det

Synchrotron-based X-ray Fluorescence Ghost Imaging

X-ray Fluorescence Ghost Imaging (XRF-GI) was recently demonstrated for x-ray lab sources. It has the potential to reduce acquisition time and deposited dose by choosing their trade-off with spatial resolution, while alleviating the focusing constraints of the probing beam. Here, we demonstrate the realization of synchrotron-based XRF-GI: We present both an adapted experimental setup and its corresponding required computational technique to process the data. This extends the above-mentioned potential advantages of GI to synchrotron XRF imaging. In addition, it enables new strategies to improve resilience against drifts at all scales, and the study of previously inaccessible samples, such as liquids.

physics.optics

Brittle fracture studied by ultra-high speed synchrotron X-ray diffraction imaging

Ever since the very first human-made knapped tools, the control of fracture propagation in brittle materials has been a vector of technological development. Nowadays, a broad range of applications relies on crack propagation control, from the mitigation of damages, e.g., from impacts in glass screens or windshields, to industrial processes harnessing fracture to achieve clean cuts over large distances. Yet, studying the fracture in real time is a challenging task, since cracks can propagate up to a few km/s in materials that are often opaque. Here, we report on the in situ investigation of cracks propagating at up to 2.5 km/s along a (001) plane of a silicon single crystal, using X-ray diffraction megahertz imaging with intense and time-structured synchrotron radiation. The studied system is based on the Smart Cut process, where a buried layer in a material (typically Si) is weakened by micro-cracks and then used to drive a macroscopic crack (0.1 m) in a plane parallel to the surface with minimal deviation (1 nm). The results we report here provide the first direct confirmation that the shape of the crack front is not affected by the distribution of the micro-cracks, which had been a postulate for previous studies based on post-fracture results. We further measured instantaneous crack velocities over the centimeter-wide field-of-view, which had only been previously inferred from sparse point measurements, and evidence the effect of local heating by the X-ray beam. Finally, we also observed the post-crack movements of the separated wafer parts, which can be explained using pneumatics and elasticity. Thus, this study provides a comprehensive view of controlled fracture propagation in a crystalline material, paving the way for the in situ measurement of ultra-fast strain field propagation.

cond-mat.mtrl-sci

Ghost projection. II. Beam shaping using realistic spatially-random masks

Spatial light modulation is important for many scientific and industrial applications. The spatial light modulator and optical data projector both rely on precisely configurable optical elements to shape a light beam. Here we explore an image-projection approach which does not require a configurable beam-shaping element. We term this approach ghost projection on account of its conceptual relation to computational ghost imaging. Instead of a configurable beam shaping element, the method transversely displaces a single illuminated mask, such as a spatially-random screen, to create specified distributions of radiant exposure. The method has potential applicability to image projection employing a variety of radiation and matter wave fields, such as hard x rays, neutrons, muons, atomic beams and molecular beams. Building on our previous theoretical and computational studies, we here seek to understand the effects, sensitivity, and tolerance of some key experimental limitations of the method. Focusing on the case of hard x rays, we employ experimentally acquired masks to numerically study the deleterious effects of photon shot noise, inaccuracies in random-mask exposure time, and inaccuracies in mask positioning, as well as adapting to spatially non-uniform illumination. Understanding the influence of these factors will assist in optimizing experimental design and work towards achieving ghost projection in practice.

eess.IV

Boosting spatial resolution by incorporating periodic boundary conditions into single-distance hard-x-ray phase retrieval

A simple coherent-imaging method due to Paganin et al. is widely employed for phase-amplitude reconstruction of samples using a single paraxial x-ray propagation-based phase-contrast image. The method assumes that the sample-to-detector distance is sufficiently small for the associated Fresnel number to be large compared to unity. The algorithm is particularly effective when employed in a tomographic setting, using a single propagation-based phase-contrast image for each projection. Here we develop a simple extension of the method, which improves the reconstructed contrast of very fine sample features. This provides first-principles motivation for boosting fine spatial detail associated with high Fourier frequencies, relative to the original method, and was inspired by several recent works employing empirically-obtained Fourier filters to a similar end.

eess.IV

3D characterization of the primary Al3Sc phases in an Al-Sc alloy using Synchrotron X-ray tomography and electron microscopy

The three-dimensional structures of the primary Al3Sc particles in an Al-2Sc master alloy were studied by synchrotron X-ray microtomography, scanning and transmission electron microscopy. The Al3Sc phases were found to be a single cube and a cluster of cubes. The surface area, equivalent diameter of the Al3Sc cubes increased with the increasing of cube volume, but the specific surface area decreases. The primary Al3Sc cubes and Al-matrix have the same crystal orientation, indicating that the Al3Sc phases are the heterogeneous nucleation sites for Al. The experimental results show that {\alpha}-Al2O3 are the possible nucleation sites for the Al3Sc cubes.

cond-mat.mtrl-sci

Megahertz X-ray microscopy at X-ray Free-Electron Laser and Synchrotron sources

We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glass explosions are observed. The comparison between XFEL and previous synchrotron MHz microscopy shows the superior contrast and spatial resolution at the XFEL over the synchrotron. This work opens up new possibilities for the characterization of dynamic stochastic systems on nanosecond to microsecond time scales at megahertz rate with object velocities up to few kilometers per second using X-ray Free-Electron Laser sources.

physics.ins-det

Phase-sensitive x-ray ghost imaging

Imaging with hard x-rays is an invaluable tool in medicine, biology, materials science, and cultural heritage. Propagation-based x-ray phase-contrast imaging and tomography have been mostly used to resolve micrometer-scale structures inside weakly absorbing objects as well as inside dense specimens. Indirect x-ray detection has been the key technology to achieve up to sub-micrometer spatial resolutions, albeit inefficiently and hence at the expense of increased radiation dose to the specimen. A promising approach to low-dose imaging and high spatial resolution even at high x-ray energies is ghost imaging, which could use single-pixel, yet efficient direct x-ray detectors made of high-density materials. However, phase contrast has not yet been realised with x-ray ghost imaging. We present an approach which exploits both the advantages of x-ray ghost imaging and the high sensitivity of phase-contrast imaging. In comparison with existing techniques, our method is efficient and achieves high-fidelity x-ray ghost images with phase contrast, accurate density resolution and dramatically higher spatial resolution. The method is scalable to practical tomography with large fields of view, micrometer spatial resolution, and with high-energy x-rays above 100 keV. It is also applicable to other phase-sensitive imaging techniques and with other probes such as neutrons, alpha rays, and muons, for which high spatial resolution detectors are limited or even not available.

eess.IV

Ghost Tomography

Ghost tomography using single-pixel detection extends the emerging field of ghost imaging to three dimensions, with the use of penetrating radiation. In this work, a series of spatially random x-ray intensity patterns is used to illuminate a specimen in various tomographic angular orientations with only the total transmitted intensity being recorded by a single-pixel camera (or bucket detector). The set of zero-dimensional intensity readings, combined with knowledge of the corresponding two-dimensional illuminating patterns and specimen orientations, is sufficient for three-dimensional reconstruction of the specimen. The experimental demonstration of ghost tomography is presented here using synchrotron hard x-rays. This result expands the scope of ghost imaging to encompass volumetric imaging (i.e., tomography), of optically opaque objects using penetrating radiation. For hard x-rays, ghost tomography has the potential to decouple image quality from dose rate as well as image resolution from detector performance.

physics.ins-det

Practical x-ray ghost imaging with synchrotron light

We present a practical experimental realization of transmission x-ray ghost imaging using synchrotron light. Hard x-rays from an undulator were split by a Si 200 crystal in Laue geometry to produce two copies of a speckled incident beam. Both speckle beams were simultaneously measured on a CCD camera. The sample was inserted in one of the two beams, and the corresponding image was integrated over the camera extent to synthesize a bucket signal. We show the successful x-ray ghost image reconstruction of two samples and discuss different reconstruction strategies. We also demonstrate a method for measuring the point spread function of a ghost imaging system, which can be used to quantify the resolution of the ghost imaging reconstructions and quantitatively compare different reconstruction approaches. Our experimental results are discussed in view of future practical applications of x-ray ghost imaging, including a means for parallel ghost imaging.

physics.ins-det

Experimental x-ray ghost imaging

We report an experimental proof of principle for ghost imaging in the hard x-ray energy range. We used a synchrotron x-ray beam that was split using a thin crystal in Laue diffraction geometry. With an ultra-fast imaging camera, we were able to image x-rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, leading to speckle correlation between the two beams. The integrated transmitted intensity from a sample located in the first beam was correlated with the spatially resolved intensity measured on the second, empty, beam to retrieve the shadow of the sample. The demonstration of ghost imaging with hard x-rays may open the way to protocols to reduce radiation damage in medical imaging and in non-destructive structural characterization using Free Electron Lasers.

physics.optics