7 recordsLinked to original sources

Rapid quantitative chemical composition mapping using model-based MRI reconstruction with field inhomogeneity correction

Magnetic resonance spectroscopic imaging methods are particularly attractive for chemical engineering applications, including the monitoring of chemical reactions, where a rapid assessment of spatial variations in chemical composition is required. Conventional approaches, such as chemical shift imaging, introduce an additional spectral-encoding dimension, which substantially increases acquisition time. Consequently, fast spatially resolved spectroscopy remains an active research topic. This work uses a model-based reconstruction framework that embeds a priori spectral knowledge of the involved chemical components into the forward model to accelerate composition mapping. It allows for the reconstruction of molar ratio maps for individual chemical components without acquiring high-resolution spectra. Extending from previous studies, the proposed model accounts for inhomogeneities of the main field, which become more pronounced in systems with larger bores relevant for process engineering. Phantom experiments employing a 2D multi-gradient echo sequence demonstrate the ability to determine molar ratios for chemical components with single peaks as well as multiple peaks in their spectra. The bias and precision of the method remain around 0.01 mol/mol and 0.09 mol/mol, respectively, for a 20 s scan, indicating suitability for dynamic processes. Finally, acquisition time can be reduced further by applying sparse k-space sampling, potentially shortening the scan to 5 s with only minor degradation in quantitative performance.

eess.IV

Comprehensive Study of 3D Liquid Flow Fields in Additive Manufactured Structures for SMART Reactors Using Large-Scale Vertical Magnetic Resonance Imaging and Computational Fluid Dynamics

Triply Periodic Minimal Surface (TPMS) structures have emerged as a new class of porous materials with variable geometries and favourable transport properties, making them promising for reactor internals in chemical engineering. However, experimental data on internal TPMS flow behaviour are still limited. To address this gap, the flow behaviour in additively manufactured TPMS structures is analysed using three-dimensional Magnetic Resonance Imaging (MRI) velocimetry in a large-bore vertical 3 T MRI system, in cylindrical columns of 38 mm diameter and Reynolds numbers between 50 and 300. Three different TPMS geometries are investigated, and consistency between Computational Fluid Dynamics (CFD) simulations and experimentally measured MRI velocity fields is established through cross-validation. The MRI system provides fully three-dimensional velocity fields with a divergence deviation below 6 %. MRI revealed distinct flow features: the Gyroid TPnS exhibited pronounced channelling, while the Schwarz-Diamond TPSf showed merge-split behaviour, achieving a 46 % increase in lateral mixing compared to the Gyroid TPnS structures. Numerical simulations reproduce the flow features and show agreement with the MRI data. The combined methodology demonstrates the suitability of MRI velocimetry for the experimental validation of CFD simulations and establishes a robust foundation for future studies of heat and mass transfer, as well as reactive flow, in structured reactor systems.

physics.flu-dyn

A novel method for quantifying enzyme immobilization in porous carriers using simple NMR relaxometry

Enzyme immobilization plays a crucial role in enhancing the stability and recyclability of enzymes for industrial applications. However, traditional methods for quantifying enzyme loading within porous carriers are limited by time-consuming workflows, cumulative errors, and the inability to probe enzymes adsorbed inside the pores. In this study, we introduce Time-Domain Nuclear Magnetic Resonance (TD-NMR) relaxometry as a novel, non-invasive technique for directly quantifying enzyme adsorption within porous carriers. Focusing on epoxy methyl acrylate carriers, commonly used in biocatalysis, we correlate changes in T2 relaxation times with enzyme concentration, leading to the development of an NMR-based pore-filling ratio that quantifies enzyme loading. Validation experiments demonstrate that TD-NMR-derived adsorption curves align closely with traditional photometric measurements, offering a reliable and reproducible alternative for enzyme quantification. The accessibility of tabletop TD-NMR spectrometers makes this technique a practical and cost-effective tool for optimizing biocatalytic processes. Furthermore, the method holds promise for real-time monitoring of adsorption dynamics and could be adapted for a wider range of carrier materials and enzymes.

cond-mat.soft

Enhancing Swelling Kinetics of pNIPAM Lyogels: The Role of Crosslinking, Copolymerization, and Solvent

Stimuli-responsive lyogels are known for their ability to undergo significant macroscopic changes when exposed to external stimuli. While thermo-responsive gels, such as poly N isopropylacrylamide (pNIPAM), have been extensively studied across various applications, solvent-induced swelling has predominantly been investigated in aqueous solutions. This study explores the tailoring of lyogel formulations for future applications by controlling their solvent-induced swelling behavior, comparing both homopolymeric and semi-interpenetrating polymer networks (semi-IPNs). In contrast to most previous studies, the impact of chemical and physical crosslinking, as well as copolymer inclusion, on the swelling behavior and mechanical properties of lyogels in organic solvents is examined and compared with solvent-induced swelling kinetics measurements. The results demonstrate that increasing chemically crosslinking in homopolymers and physically crosslinking in semi-IPNs enhances mechanical stability, while improving mass transport properties and solvent exchange kinetics. However, increases degree of crosslinking results in a prolonged response time to the solvent exchange stimulus and a reduction in the overall swelling capacity of the lyogels. Furthermore, variations in solvent properties, including molecular size and diffusion rates, significantly influence the swelling kinetics, whereas smaller, faster-diffusing solvents leading to more pronounced solvent spillage effects. Our findings highlight the complex interplay between gel formulation, network structure, and solvent nature in determining the solvent-induced swelling kinetics of lyogels, providing insights into how these materials can be tailored for specific applications especially those requiring short response times and optimized mechanical properties.

cond-mat.soft

The effect of baffles on the hydrodynamics of a gas-solid fluidized bed studied using real-time magnetic resonance imaging

Understanding and predicting the hydrodynamics of gas bubbles and particle-laden phase in fluidized beds is essential for the successful design and efficient operation of this type of reactor. In this work, we used real-time magnetic resonance imaging (MRI) to investigate the effect of baffles on gas bubble behavior and particle motion in a fluidized bed model with an inner diameter of 190 mm. MRI time series of the local particle density and velocity were acquired and used to study the size, number, and shape of gas bubbles as well as the motion of the particle phase. The superficial gas velocity was varied between 1 and 2 Umf . We found that baffles decreased the average equivalent bubble diameter with a simultaneous increase in the total number of bubbles. Moreover, baffles promoted bubble splitting and the formation of air cushions below the baffles and decreased the average particle velocity and acceleration in the bed. For two of the three investigated baffle types, the particle velocity distribution became wider compared to the bed without internal.

physics.flu-dyn

Temperature distribution in a gas-solid fixed bed probed by rapid magnetic resonance imaging

Controlling the temperature distribution inside catalytic fixed bed reactors is crucial for yield optimization and process stability. Yet, in situ temperature measurements with spatial and temporal resolution are still challenging. In this work, we perform temperature measurements in a cylindrical fixed bed reactor by combining the capabilities of real-time magnetic resonance imaging (MRI) with the temperature-dependent proton resonance frequency (PRF) shift of water. Three-dimensional (3D) temperature maps are acquired while heating the bed from room temperature to 60~$^{\circ}$C using hot air. The obtained results show a clear temperature gradient along the axial and radial dimensions and agree with optical temperature probe measurements with an average error of $\pm$ 1.5~$^{\circ}$C. We believe that the MR thermometry methodology presented here opens new perspectives for the fundamental study of mass and heat transfer in gas-solid fixed beds and in the future might be extended to the study of reactive gas-solid systems.

cond-mat.soft

The Link Between Packing Morphology and the Distribution of Contact Forces and Stresses in Packings of Highly Non-Convex Particles

An external load on a particle packing is distributed internally through a heterogeneous network of particle contacts. This contact force distribution determines the stability of the particle packing and the resulting structure. Here, we investigate the homogeneity of the contact force distribution in packings of highly non-convex particles both in two-dimensional (2D) and three-dimensional (3D) packings. A newly developed discrete element method is used to model packings of non-convex particles of varying sphericity. Our results establish that in 3D packings the distribution of the contact forces in the normal direction becomes increasingly heterogeneous with decreasing particle sphericity. However, in 2D packings the contact force distribution is independent of particle sphericity, indicating that results obtained in 2D packings cannot be extrapolated readily to 3D packings. Radial distribution functions (RDFs) show that the crystallinity in 3D packings decreases with decreasing particle sphericity. We link the decreasing homogeneity of the contact force distributions to the decreasing crystallinity of 3D packings. These findings are complementary to the previously observed link between the heterogeneity of the contact force distribution and a decreasing packing crystallinity due to an increasing polydispersity of spherical particles.

cond-mat.soft