arXiv ScienceSearch

arXiv subjects

Alexander Deisting

Publications and source records attributed to Alexander Deisting.

12 recordsLinked to original sources

GRANITE: Mechanical Characterization and Optical Inspection of Large-Area TPC Electrodes

Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for mechanical stability and high-voltage performance of such an experiment, we have developed a scanning setup for electrode quality assurance called GRANITE: Granular Robotic Assay for Novel Integrated TPC Electrodes. GRANITE is built around a gantry robot on top of a $2.5\,\text{m}\times1.8\,\text{m}$ granite table, equipped with a suite of non-contact metrology devices. We demonstrate the setup's capabilities in two key areas: first, using laser scanners, we characterize wire tension, and in an independent measurement wire deflection due to gravity and electrostatic forces is determined. The setup achieves a precision of $20\,\mu\text{m}$ for the relative measurement of only electrostatic displacement. Furthermore, GRANITE can measure gravitational sag down to $200\,\mu\text{m}$ in an absolute measurement; this precision improves to $50\,\mu\text{m}$ when applying model-based corrections for systematic effects. The performance achieved exceeds the needs for the characterisation of the electrode sagging in future experiments, which typically aims to ensure a maximal sag on the order of $500\,\mu\text{m}$. Second, we use GRANITE's high resolution camera to image all wires of XENON1T's cathode grid. Subsets of these images are then hand sorted and used to train an autoencoder, to reliably classify wire images as either pristine wires or images containing severe anomalous features. These anomalies appear e.g. as staining and may be potential defects. The interpretation of the classification results is complicated by the fact that most wire segments are not spotless, but show a varying amount of anomalous features. Follow-up studies are needed to identify the exact nature of such features on wires.

physics.ins-det

GRANITE: High-Resolution Imaging and Electrical Qualification of Large-Area TPC Electrodes

Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for high-voltage performance of such an experiment, we have developed a scanning setup for comprehensive electrode quality assurance. The system is built around the GRANITE (Granular Robotic Assay for Novel Integrated TPC Electrodes) facility: a gantry robot on top of a $2.5\,\text{m}\times1.8\,\text{m}$ granite table, equipped with a suite of non-contact metrology devices. We developed a coaxial wire scanning head to measure and correlate localized high-voltage discharge currents in air with high-resolution surface images. We find that the identified discharge 'hotspots' are transient and show no significant correlation with static visual features. Next, we established a quantitative relationship between artificially induced abrasive surface damage on the wires and a reduction in the discharge inception voltage. This work provides a novel non-invasive tool for qualifying wires dedicated for use in electrodes for future low-background experiments.

physics.ins-det

ARIADNE+: Large scale demonstration of fast optical readout for dual-phase LArTPCs at the CERN Neutrino Platform

Optical readout of large scale dual-phase liquid Argon TPCs is an attractive alternative to charge readout and has been successfully demonstrated on a 2x2m active region within the CERN protoDUNE cold box. ARIADNE+ uses four Timepix3 cameras imaging the S2 light produced by 16 novel, patent pending, glass THGEMs. ARIADNE+ takes advantage of the raw Timepix3 data coming natively 3D and zero suppressed with a 1.6ns timing resolution. Three of the four THGEM quadrants implement readout in the visible light range through wavelength shifting, with the fourth featuring a VUV light intensifier, thus removing the need for wavelength shifting altogether. Cosmic ray reconstruction and energy calibration was performed. Presented is a summary of the detector setup and experimental run, preliminary analysis of the run data and future outlook for the ARIADNE program.

physics.ins-det

Contextual Isotope Ranking Criteria for Peak Identification in Gamma Spectroscopy Using a Large Database

Isotope identification is a recurrent problem in gamma spectroscopy with high purity germanium detectors. In this work, new strategies are introduced to facilitate this type of analysis. Five criteria are used to identify the parent isotopes making a query on a large database of gamma-lines from a multitude of isotopes producing an output list whose entries are sorted so that the gamma-lines with the highest chance of being present in a sample are placed at the top. A metric to evaluate the performance of the different criteria is introduced and used to compare them. Two of the criteria are found to be superior than the others: one based on fuzzy logic, and another that makes use of the gamma relative emission probabilities. A program called histoGe implements these criteria using a SQLite database containing the gamma-lines of isotopes which was parsed from WWW Table of Radioactive Isotopes. histoGe is Free Software and is provided along with the database so they can be used to analyze spectra obtained with generic gamma-ray detectors.

physics.comp-ph

Commissioning of a hybrid readout TPC test set-up and gas gain simulations

A hybrid readout Time Projection Chamber (TPC) has a simultaneous optical- and charge readout. The optical readout provides 2D images of particle tracks in the active volume, whilst the charge readout provides additional information on the particle position perpendicular to the image plane. A hybrid readout TPC working at high pressure is an attractive device for physics cases where an excellent space point resolution and a high target density is required as e.g. measuring a neutrino beam at the source of a long baseline neutrino oscillation experiment. In this paper we present two different lines of work towards the goal of developing hybrid TPC technology: a) Commissioning of a set-up with gas electron multipliers employing optical and charge readout. b) An analytical parametrisation of the gas gain for a multi wire proportional chamber based on garfield++ simulations, which - when validated with measurements - allows to skip these simulations in the future altogether.

physics.ins-det

A High Pressure Time Projection Chamber with Optical Readout

Measurements of proton-nucleus scattering and high resolution neutrino-nucleus interaction imaging are key to reduce neutrino oscillation systematic uncertainties in future experiments. A High Pressure Time Projection Chamber (HPTPC) prototype has been constructed and operated at Royal Holloway University of London and CERN as a first step in the development of a HPTPC capable of performing these measurements as part of a future long-baseline neutrino oscillation experiment such as the Deep Underground Neutrino Experiment. In this paper we describe the design and operation of the prototype HPTPC with an argon based gas mixture. We report on the successful hybrid charge and optical readout, using four CCD cameras, of signals from Am-241 sources.

physics.ins-det

Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $\gamma$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of x-rays and low energy $\gamma$-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2 %. The Neo sCMOS is not sensitive to x-rays with energies below $\sim\!\!10 keV$. The smallest detectable rate is 40$\pm$3 mHz, corresponding to an incident activity on the chip of 7$\pm$4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08$\pm$0.02 % (0.0011$\pm$0.0002 %) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4$\pm$1 mHz (1.5$\pm$0.1 mHz) for 26.3 keV (59.5 keV) $\gamma$-rays, which corresponds to an incident activity of 1.0$\pm$0.6 Bq (57$\pm$33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a $\gamma$- and x-ray detector with sensitivity at the few to 100 ppb level for Lead-210 in a sample.

physics.ins-det

Towards a low cost lead assay technique for drinking water using CMOS sensors

An estimated 26 million people in low- and middle-income countries are at risk of lead exposure and there is no safe threshold for lead ingestion. Radio assay methods are not easily accessible in regions at risk, therefore a low cost and easy to use sensor is desirable. $\textrm{Pb}$ occurs together with traces of radioisotopes with decay energies in the range of $10$ to several \SI{100}{\kilo\electronvolt} and beyond. Such energies are accessible in silicon sensors. We have tested a scientific CMOS (Neo 5.5 sCMOS), optimised for optical wavelengths, as $\gamma$ detector for radiation in the range of $0$ to a few 10 keV. We find a minimal detectable $^{241}\textrm{Am}$ decay rate of 20 Bq for a < 1.4h measurement. Optimising our analysis software will potentially enable detecting lower rates in the same measurement time. We established that the Neo 5.5 sCMOS allows to measure a spectrum of $^{241}\textrm{Am}$ decay lines. In addition we show that it is possible to enhance the concentration of radioisotopes in water when reducing the water's volume by boiling. The knowledge gained using the scientific CMOS sensor will be transferred to commercial silicon sensors as the chips in smart phones.

physics.ins-det

Ion mobility measurements in Ar-CO$_2$, Ne-CO$_2$, and Ne-CO$_2$-N$_{2}$ mixtures, and the effect of water contents

A detector has been constructed for measuring ion mobilities of gas mixtures at atmospheric pressure and room temperature. The detector consists of a standard triple GEM amplification region and a drift region where ions drift. A method has been developed to measure the ions' arrival time at a cathode wire-grid by differentiating the recorded signals on this electrode. Simulations prove that this method is accurate and robust. The ion mobility in different gas mixtures is measured while applying different drift field values ranging from 200 V cm$^{-1}$ to 1100 V cm$^{-1}$. From an extrapolation of a Blanc's law fit to measurements in Ar-CO$_2$ mixtures we find the reduced mobility of the drifting (cluster) ion species in pure argon to be $1.94\pm0.01$ cm$^{2}$ V$^{-1}$ s$^{-1}$ and in pure carbon-dioxide to be $1.10\pm0.01$ cm$^{2}$ V$^{-1}$ s$^{-1}$. Applying the same procedure to our measurements in Ne-CO$_2$ yields $4.06\pm0.07$ cm$^{2}$ V$^{-1}$ s$^{-1}$ and $1.09\pm0.01$ cm$^{2}$ V$^{- 1}$ s$^{-1}$ for the reduced mobilities in pure neon and carbon-dioxide, respectively. Admixtures of N$_2$ to Ne-CO$_2$ reduce somewhat the mobility. For the baseline gas mixture of the future ALICE Time Projection Chamber, Ne- CO$_2$-N$_{2}$ (90-10-5), the measured reduced mobility of the drifting ions is $2.92\pm0.04$ cm$^{2}$ V$^{-1}$ s$^{-1}$. Ion mobilities are examined for different water content ranging from 70 ppm to about 2000 ppm in the gas using Ar-CO$_2$ (90-10) and Ne-CO$_2$ (90-10). A slight decrease of ion mobility is observed for the addition of several hundred ppm of water.

physics.ins-det

Discharge and stability studies for the new readout chambers of the upgraded ALICE TPC

The ALICE (A Large Ion Collider Experiment) Time Projection Chamber (TPC) at CERN LHC is presently equipped with Multi Wire Proportional Chambers (MWPCs). A gating grid prevents ions produced during the gas amplification from moving into the drift volume. The maximum drift time of the electrons together with the closure time of the gating grid allows a maximum readout rate of about 3 kHz. After the Long Shutdown 2 (from 2021 onwards), the LHC will provide lead-lead collisions at an expected interaction rate of 50 kHz. To take data at this rate the TPC will be upgraded with new readout chambers, allowing for continuous read-out and preserving the energy and momentum resolution of the current MWPCs. Chambers with a stack of four Gas Electron Multipliers (GEMs) fulfil all the performance requirements, if the voltages applied to the GEMs are tuned properly. In order to ensure that these chambers are stable while being operated at the LHC, studies of the discharge behaviour were performed. We report on studies done with small prototypes equipped with one or two GEMs. Discharges were voluntarily induced by a combination of high-voltages across the GEM(s) and highly ionising particles. During these studies, the phenomenon of "secondary discharges" has been observed. These occur only after an initial discharge when the electric field above or below the GEM is high enough. The time between the initial and the secondary discharge ranges from several 10 us to less than 1 us, decreasing with increasing field. Using decoupling resistors in the high-voltage supply path of the bottom side of the GEM shifts the occurrence of these discharges to higher electric fields.

physics.ins-det

Measurements of ion mobility in argon and neon based gas mixtures

As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run$\,3$ with a substantial space charge density of positive ions in the drift volume. In order to properly simulate such space charges, knowledge of the ion mobility $K$ is necessary. To this end, a small gaseous detector was constructed and the ion mobility of various gas mixtures was measured. To validate the corresponding signal analysis, simulations were performed. Results are shown for several argon and neon based mixtures with different $\textrm{CO}_2$ fractions. A decrease of $K$ was measured for increasing water content.

physics.ins-det

Status of the R&D activities for the upgrade of the ALICE TPC

After the Long Shutdown 2 the LHC will provide lead-lead collisions at interaction rates as high as 50kz. In order to cope with such conditions the ALICE Time Projection Chamber (TPC) needs to be upgraded. After the upgrade the TPC will run in a continuous mode, without any degradation of the momentum and dE/dx resolution compared to the performance of the present TPC. Since readout by multi-wire proportional chambers is no longer feasible with these requirements, new technologies have to be employed. In the new readout chambers the electron amplification is provided by a stack of four Gas Electron Multiplier (GEM) foils. Their high voltage settings and orientation have been optimised to provide an energy resolution better then 12% at the photopeak of 55Fe. At the same settings the Ion BackFlow into the drift volume is less than 1% of the effective number of ions produced during gas amplification and the primary ionisations. This is necessary to prevent the accumulation of space charge, which eventually will distort the field in the drift volume. To ensure stable operation at the high loads during LHC run 3 the chambers have to be robust against discharges, too. With the selected configuration in a quadruple GEM stack the discharge probability is kept at the level of $10^{-12}$ discharges per incoming hadron. An overview of the ALICE TPC upgrade activities will be given in these proceedings and the optimised settings foreseen for the GEM stacks of the future readout chambers are introduced. Furthermore the outcome of two beam time campaigns at SPS and PS (at CERN) in the end of 2014 is shown. At this campaigns the stability against discharges and the dE/dx performance of a full size readout chamber prototype was tested. In addition it is reported on charging-up studies of 4GEM stacks and on tests of electromagnetic sagging of large GEM foils.

physics.ins-det