arXiv ScienceSearch

arXiv subjects

Alex Ranne

Publications and source records attributed to Alex Ranne.

8 recordsLinked to original sources

Modular Robotic Catheters for Endovascular Aneurysm Repair

Fenestrated/Branched endovascular aneurysm repair (FEVAR/BEVAR) require surgeons to navigate catheters and guidewires into various branches of the abdominal aorta, before deploying stent grafts to alleviate pressure on the aneurysm. Previous clinical studies suggests that surgeons continue to struggle with vessel access using standard commercial instruments, prolonging the procedural time and inducing further complications. In this work, we present two contributions to solving this problem: 1) A bespoke 2-segment steerable catheter, consisting of 4 degrees of freedom to enhance dexterity. 2) An expandable, modular tendon-driven actuation platform that can accommodate for the redundancies introduced in our system. To fabricate the catheter, we capitalized on thermal fiber drawing, a technique that creates high-aspect ratio devices at scale, and processed the catheter with laser micro-machining to soften its tip. We evaluated the system using simulations, where we investigated the catheter's bending stiffness, then its steerability with in-vitro experiments in vascular phantoms. This handheld, robotic steerable catheter system has the potential to shorten the length of future endovascular surgeries, and give clinicians the tools to resolve challenging clinical cases.

cs.RO

A Mapping Sheath with Thermally Drawn Multi-Electrode Basket for Cardiac Electrophysiological Recording and Ablation Catheter Delivery

Cardiac arrhythmias, particularly atrial fibrillation, represent a major cardiovascular health burden and underscore the need for efficient and integrated strategies for electrical mapping and targeted therapy. Cardiac electrophysiology procedures depend on accurate identification of arrhythmogenic substrates followed by timely catheter ablation, but conventional diagnostic and therapeutic devices remain separate, often requiring repeated catheter exchanges and multiple access routes. Here, we report an adaptable strategy for functionalizing hollow-core sheaths with EP mapping capabilities, integrating multielectrode recording and ablation catheter delivery within a single compact platform. The device leverages thermal drawing to enable complex geometric fabrication, miniaturization, rapid prototyping, and scalable manufacturing of ultrathin electrode splines arranged circumferentially at the distal end to form an adjustable basket. The mapping sheath exhibited mechanical and electrophysiological properties suitable for intracardiac navigation and electrogram recording in bench-top evaluations, an in vitro left atrial phantom study, and ex vivo Langendorff-perfused porcine heart testing. In vivo porcine studies further demonstrated translational feasibility through vascular introduction, fluoroscopic visualization, intracardiac deployment, tissue contact, electrogram acquisition, and reconstruction of voltage and activation maps. These results support the development of intracardiac platforms with an adapted manufacturing approach, potentially guiding advances in agile cardiac mapping and ablation.

physics.med-ph

Model selection and real-time skill assessment for suturing in robotic surgery

Automated feedback systems have the potential to provide objective skill assessment for training and evaluation in robot-assisted surgery. In this study, we examine methods to achieve real-time prediction of surgical skill level in real-time based on Objective Structured Assessment of Technical Skills (OSATS) scores. Using data acquired from the da Vinci Surgical System, we carry out three main analyses, focusing on model design, their real-time performance, and their skill-level-based cross-validation training. For the model design, we evaluate the effectiveness of multimodal deep learning models for predicting surgical skill levels using synchronized kinematic and vision data. Our models include separate unimodal baselines and fusion architectures that integrate features from both modalities and are evaluated using mean Spearman's correlation coefficients, demonstrating that the fusion model consistently outperforms unimodal models for real-time predictions. For the real-time performance, we observe the prediction's trend over time and highlight correlation with the surgeon's gestures. For the skill-level-based cross-validation, we separately trained models on surgeons with different skill levels, which showed that high-skill demonstrations allow for better performance than those trained on low-skilled ones and generalize well to similarly skilled participants. Our findings show that multimodal learning allows more stable fine-grained evaluation of surgical performance and highlights the value of expert-level training data for model generalization.

cs.RO

Thermally Drawn Bioelectric Catheters: Enabling Proprioceptive Endovascular Navigation

To navigate medical instruments safely and accurately inside a patient's vascular tree, combining X-ray fluoroscopy with intermittent contrast injections is the gold standard. However, prolonged exposure to ionizing radiation poses health risks, necessitates the use of cumbersome lead vests for the clinicians, and contrast injections can lead to acute kidney injury in patients. Bioelectric Navigation, a non-fluoroscopic tracking modality, aims to provide an alternative. It uses weak electric currents to detect local anatomical features in the vasculature and localize instruments without x-ray imaging. In this work, we advance Bioelectric Navigation on two frontiers. Firstly, we introduce a new class of bespokely designed electrode catheters. They are fabricated using 3D printing, thermal drawing, and laser micro-machining. Specifically, we manufacture a 6 Fr catheter incorporating 16 electrodes, a guidewire channel and an additional sensor compartment. We thoroughly assess the catheter's mechanical and electrical properties. Secondly, we introduce an algorithm to localize the catheter along the centerline of a vascular phantom, for the first time fusing electric detection of vascular geometry with electric distance estimation. We report both tracking accuracy and usability evaluated by an expert endovascular surgeon, demonstrating the strong potential of this technology for integration into the existing clinical workflow.

physics.med-ph

Malleable Robots

This chapter is about the fundamentals of fabrication, control, and human-robot interaction of a new type of collaborative robotic manipulators, called malleable robots, which are based on adjustable architectures of varying stiffness for achieving high dexterity with lower mobility arms. Collaborative robots, or cobots, commonly integrate six or more degrees of freedom (DOF) in a serial arm in order to allow positioning in constrained spaces and adaptability across tasks. Increasing the dexterity of robotic arms has been indeed traditionally accomplished by increasing the number of degrees of freedom of the system; however, once a robotic task has been established (e.g., a pick-and-place operation), the motion of the end-effector can be normally achieved using less than 6-DOF (i.e., lower mobility). The aim of malleable robots is to close the technological gap that separates current cobots from achieving flexible, accessible manufacturing automation with a reduced number of actuators.

cs.RO

CathFlow: Self-Supervised Segmentation of Catheters in Interventional Ultrasound Using Optical Flow and Transformers

In minimally invasive endovascular procedures, contrast-enhanced angiography remains the most robust imaging technique. However, it is at the expense of the patient and clinician's health due to prolonged radiation exposure. As an alternative, interventional ultrasound has notable benefits such as being radiation-free, fast to deploy, and having a small footprint in the operating room. Yet, ultrasound is hard to interpret, and highly prone to artifacts and noise. Additionally, interventional radiologists must undergo extensive training before they become qualified to diagnose and treat patients effectively, leading to a shortage of staff, and a lack of open-source datasets. In this work, we seek to address both problems by introducing a self-supervised deep learning architecture to segment catheters in longitudinal ultrasound images, without demanding any labeled data. The network architecture builds upon AiAReSeg, a segmentation transformer built with the Attention in Attention mechanism, and is capable of learning feature changes across time and space. To facilitate training, we used synthetic ultrasound data based on physics-driven catheter insertion simulations, and translated the data into a unique CT-Ultrasound common domain, CACTUSS, to improve the segmentation performance. We generated ground truth segmentation masks by computing the optical flow between adjacent frames using FlowNet2, and performed thresholding to obtain a binary map estimate. Finally, we validated our model on a test dataset, consisting of unseen synthetic data and images collected from silicon aorta phantoms, thus demonstrating its potential for applications to clinical data in the future.

eess.IV

AiAReSeg: Catheter Detection and Segmentation in Interventional Ultrasound using Transformers

To date, endovascular surgeries are performed using the golden standard of Fluoroscopy, which uses ionising radiation to visualise catheters and vasculature. Prolonged Fluoroscopic exposure is harmful for the patient and the clinician, and may lead to severe post-operative sequlae such as the development of cancer. Meanwhile, the use of interventional Ultrasound has gained popularity, due to its well-known benefits of small spatial footprint, fast data acquisition, and higher tissue contrast images. However, ultrasound images are hard to interpret, and it is difficult to localise vessels, catheters, and guidewires within them. This work proposes a solution using an adaptation of a state-of-the-art machine learning transformer architecture to detect and segment catheters in axial interventional Ultrasound image sequences. The network architecture was inspired by the Attention in Attention mechanism, temporal tracking networks, and introduced a novel 3D segmentation head that performs 3D deconvolution across time. In order to facilitate training of such deep learning networks, we introduce a new data synthesis pipeline that used physics-based catheter insertion simulations, along with a convolutional ray-casting ultrasound simulator to produce synthetic ultrasound images of endovascular interventions. The proposed method is validated on a hold-out validation dataset, thus demonstrated robustness to ultrasound noise and a wide range of scanning angles. It was also tested on data collected from silicon-based aorta phantoms, thus demonstrated its potential for translation from sim-to-real. This work represents a significant step towards safer and more efficient endovascular surgery using interventional ultrasound.

eess.IV

Identifying visible tissue in intraoperative ultrasound: a method and application

Purpose: Intraoperative ultrasound scanning is a demanding visuotactile task. It requires operators to simultaneously localise the ultrasound perspective and manually perform slight adjustments to the pose of the probe, making sure not to apply excessive force or breaking contact with the tissue, whilst also characterising the visible tissue. Method: To analyse the probe-tissue contact, an iterative filtering and topological method is proposed to identify the underlying visible tissue, which can be used to detect acoustic shadow and construct confidence maps of perceptual salience. Results: For evaluation, datasets containing both in vivo and medical phantom data are created. A suite of evaluations is performed, including an evaluation of acoustic shadow classification. Compared to an ablation, deep learning, and statistical method, the proposed approach achieves superior classification on in vivo data, achieving an F_beta score of 0.864, in comparison to 0.838, 0.808, 0.808. A novel framework for evaluating the confidence estimation of probe tissue contact is created. The phantom data is captured specifically for this, and comparison is made against two established methods. The proposed method produced the superior response, achieving an average normalised root mean square error of 0.168, in comparison to 1.836 and 4.542. Evaluation is also extended to determine the algorithm's robustness to parameter perturbation, speckle noise, data distribution shift, and capability for guiding a robotic scan. Conclusion: The results of this comprehensive set of experiments justify the potential clinical value of the proposed algorithm, which can be used to support clinical training and robotic ultrasound automation.

eess.IV