arXiv ScienceSearch

arXiv subjects

Alejandro Guzman

Publications and source records attributed to Alejandro Guzman.

7 recordsLinked to original sources

Dense Temporal Contrast Synthesis via Conditioned Latent Transport

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is essential for breast cancer management, but reliance on gadolinium-based contrast agents (GBCAs) restricts use in contraindicated populations, prolongs scan protocols, and presents environmental toxicity concerns. Contrast synthesis offers a non-invasive alternative; however, existing approaches struggle to balance spatial realism with temporal continuity, suffer from slow iterative sampling, underutilize structural priors, and lack clinical validation. We propose a novel conditioned latent transport framework that predicts contrast enhancement in a single forward pass. By anchoring the latent trajectory to the pre-contrast anatomy and applying continuous time conditioning, the model synthesizes patient-specific contrast evolution at any acquisition time. The proposed approach outperforms baseline and the state-of-the-art models across spatial, perceptual, temporal, and distributional metrics. Evaluated on an independent external cohort, the method demonstrates robustness to domain shifts induced by scanner noise as well as differing acquisition protocol. Furthermore, our synthetic contrast enhancement significantly improved downstream tumor segmentation performance, yielding a 22.4% relative increase in Dice coefficient (0.60 vs. 0.49 baseline pre-contrast, p < 0.01), reducing boundary segmentation error by over 39%, while outperforming all other generative model baselines. Finally, a reader study involving four breast radiologists evaluated the image quality, kinetic fidelity, and diagnostic viability of our synthesized sequences across 40 randomly selected cases. The results demonstrated that in 70% of cases, synthesized images provided sufficient clinical information to support the same management decisions as real DCE-MRI, suggesting a path toward safer and faster contrast-free or contrast-reduced imaging workflows.

cs.CV

Regulatory Approval Is Not Enough: Gaps in Trustworthy AI Reporting in FDA-Cleared Medical Devices

Background: AI/ML-enabled medical devices are increasingly deployed in healthcare under evolving regulatory frameworks. As these systems become more integrated into clinical decision-making, there is growing expectation that they demonstrate key dimensions of trustworthy AI to support clinician, patient, and public trust. Whether publicly available regulatory documentation provides sufficient evidence to independently assess the trustworthiness of cleared AI systems remains unclear. Methods: We analysed FDA AI/ML-enabled medical device summary reports published between 2021 and 2025. Reports underwent automated keyword screening followed by multi-stage manual consensus review to identify documented evidence for the six FUTURE-AI principles: Fairness, Universality, Traceability, Usability, Robustness, and Explainability. Descriptive, temporal, and clinical-domain analyses were performed. Multivariable logistic regression assessed whether year of clearance or clinical domain predicted higher reporting transparency, defined as evidence reported for three or more principles. Results: Of 1,105 FDA summary reports screened, 519 were included. Trustworthy AI reporting was limited and uneven. Nearly one quarter (24.7%) provided no evidence for any principle, and none documented evidence across all six. Robustness was most frequently reported (57.6%), while Traceability (8.3%) and Explainability (3.5%) were the most pronounced gaps. Neither year of clearance (OR 1.02, 95% CI 0.88-1.19) nor clinical domain (OR 0.73, 95% CI 0.46-1.15) predicted higher reporting transparency. Interpretation: Substantial, persistent trustworthy AI reporting gaps exist in FDA documentation. Regulatory approval alone should not be considered a proxy for trustworthiness. Standardised, audit-ready reporting across the AI lifecycle is needed to support independent assessment and responsible adoption of healthcare AI.

cs.CY

Design and preliminary performance study of the broad-band spectrometer detector for POLAR-2

POLAR-2, the successor of the POLAR experiment aboard China's Tiangong-2 space lab, is set to be deployed on the China Space Station. The POLAR-2 mission aims to conducting high-precision polarization measurements of high-energy transients with a primary focus on Gamma-Ray Bursts (GRBs), following POLAR's pioneering accurate polarization measurements of GRB prompt emission. One of the key advancements in POLAR-2 is the inclusion of a dedicated Broad-band Spectrometer Detector (BSD) instrument, designed to provide precise measurements of GRB location and spectral parameters, which are critical inputs for accurate polarization analysis of POLAR-2's dedicated High-energy Polarimetry Detector (HPD), which is made of plastic scintillator bars array. BSD employs a coded-aperture mask imaging technique and pixelated GAGG scintillation crystals, offering a wide half-coded field of view of ~132{\deg} x 125{\deg} and an operational energy range of 10-1000 keV. Simulation results indicate that the instrument can achieve a localization accuracy of approximately 1.5{\deg} for faint GRBs similar to GRB 170817A, satisfying the core requirements of GRB polarimetry with HPD. BSD also has moderate capability for GRB polarimetry, particularly at several hundred keV energy. This paper outlines the preliminary design of BSD and presents an overall evaluation of its expected scientific performance, based on extensive Monte Carlo simulations and preliminary ground-based calibration tests.

astro-ph.IM

POLAR-2 -- Latest Developments of the Next Generation GRB Polarimeter

Gamma-Ray Bursts (GRBs) are among the most energetic events in the Universe. Despite over 50 years of research and measurements their prompt emission remains poorly understood, with key questions surrounding the structure of relativistic jets, magnetic field configurations, and dominant radiation mechanisms. Polarization measurements are critical in resolving these uncertainties. The POLAR mission, operational in 2016-2017 on Tiangong-2, provided the most statistically significant GRB polarization data. Its results indicated low time-averaged polarization with hints of temporal evolution. However, POLAR's limited sensitivity, small effective area, and restricted energy range prevented more detailed time- and energy-resolved analyses in addition to a larger sample of GRB polarization measurements. POLAR-2 is designed to address these limitations by offering a fourfold increase in effective area (at least) and an extended energy range of 30-800 keV by utilizing Silicon Photomultipliers (SiPMs) and an updated module design, enabling the differentiation of competing GRB emission models. The instrument comprises of 100 polarimeter modules (each with 64 plastic scintillator bars), wherein the polarization angle is extracted through Compton Scattering of the gammas. The polarimeter module design was validated during an ESRF beam test campaign in 2023. The instrument was developed by a joint effort of Switzerland, China, Poland and Germany and is planned for launch in 2027. Currently, POLAR-2 is in its production phase with the first module targets being produced. We will provide an overview of the current status of the development.

astro-ph.IM

STROBE-X High Energy Modular Array (HEMA)

The High Energy Modular Array (HEMA) is one of three instruments that compose the STROBE-X mission concept. The HEMA is a large-area, high-throughput non-imaging pointed instrument based on the Large Area Detector developed as part of the LOFT mission concept. It is designed for spectral timing measurements of a broad range of sources and provides a transformative increase in sensitivity to X-rays in the energy range of 2--30 keV compared to previous instruments, with an effective area of 3.4 m$^{2}$ at 8.5 keV and an energy resolution of better than 300 eV at 6 keV in its nominal field of regard.

astro-ph.IM

SpIRIT Mission: In-Orbit Results and Technology Demonstrations

The Space Industry Responsive Intelligent Thermal (SpIRIT) 6U CubeSat is a mission led by The University of Melbourne in cooperation with the Italian Space Agency. Launched in a 510 km Polar Sun Synchronous Orbit in December 2023, SpIRIT carries multiple subsystems for scientific and technology demonstration. The main payload is the HERMES instrument for detection of high-energy astrophysics transients (Gamma Ray Bursts), and for studies of their variability at scales below 1 ms. The satellite includes a novel thermal management system for its class, based on a Stirling-cycle cooler and deployable thermal radiator, designed to cool HERMES to reduce instrumental background noise. A low-latency communication subsystem based on a sat-phone network is supporting rapid transmission of time-critical data and telecommands. SpIRIT is also equipped with a set of RGB and thermal IR cameras, connected to an on-board image processing unit with artificial intelligence capabilities for autonomous feature recognition. To effectively manage all interfaces between different subsystems and mission stakeholders, the University of Melbourne developed an instrument control unit (PMS) which operates all payloads. PMS also provides backup uninterruptible power to the HERMES instrument through a supercapacitor-based UPS for safe instrument shutdown in case of platform power interruptions. This paper first presents a mission and payload overview, and early in-orbit results, along with lessons learned throughout the mission. This work not only sheds light on the novelty of some of the on-board technologies onboard and on their potential impact to enable greater utilization of CubeSats for scientific missions, but also offers insights into the practical challenges and accomplishments related to developing and operating a multi-organization CubeSat with a complex array of instruments and systems.

astro-ph.IM

HERMES-Pathfinder

HERMES-Pathfinder is a constellation of six 3U nano-satellites hosting simple but innovative X-ray detectors for determining the positions of, and monitoring cosmic high-energy transients such as gamma-ray bursts and the electromagnetic counterparts of gravitational Wave Events. The HERMES Technological Pathfinder project is funded by the Italian Space Agency, while the HERMES Scientific Pathfinder project is funded by the European Union's Horizon 2020 Research and Innovation Programme under Grant Agreement No. 821896. HERMES-Pathfinder is an in-orbit demonstration, that should be tested in orbit starting in 2023. We present the main scientific goals of HERMES-Pathfinder, as well as a description of the HERMES-Pathfinder payload and performance.

astro-ph.IM