arXiv Science⌕ Search

arXiv subjects

Albert Hsiao

Publications and source records attributed to Albert Hsiao.

4 recordsLinked to original sources

Distinguishing Extraction Failures and Clinical Discordance with LLM Uncertainty on Radiology Reports

Large language models (LLMs) are increasingly used to structure data from unstructured text, but extraction errors remain inevitable. We evaluated whether LLM uncertainty could distinguish extraction failure from true clinical discordance. In 5{,}225 vessels from 1{,}045 patients undergoing coronary CT angiography (CCTA) for suspected coronary artery disease (CAD), we evaluated token-level and self-reported LLM uncertainty during extraction of vessel-level stenosis severity. Extraction failure was defined as disagreement between LLM-extracted stenosis and expert annotations. Clinical discordance was defined as disagreement in obstructive CAD status between CCTA and subsequent invasive coronary angiography (ICA). Incremental discrimination was assessed after adjustment for stenosis severity, calcium burden, and coronary vessel. Extraction failure was evaluated in 1{,}077 vessels from 253 patients with expert annotations, and clinical discordance in 1{,}641 vessels from 729 patients undergoing ICA within 90 days. Token-level Stenosis Margin showed the strongest association with extraction failure (adjusted OR, 4.15 [95\% CI, 2.57--6.69]; $P<0.001$) and clinical discordance (adjusted OR, 1.22 [95\% CI, 1.04--1.43]; $P=0.118$). Stenosis Margin significantly improved discrimination of extraction failure ($Δ$AUC, +0.06 [95\% CI, +0.03 to +0.09]; $P=0.001$), but not clinical discordance ($Δ$AUC, +0.01 [95\% CI, $-0.00$ to +0.02]; $P=0.245$). In a nested cohort of 138 vessels from 57 patients, 38 of 42 clinically discordant vessels (90\%) were extracted correctly. LLM uncertainty improved identification of extraction failure but not clinical discordance, suggesting that uncertainty may identify errors introduced during data extraction but may not generalize to discordance in underlying clinical data.

cs.CL↗

Integrated Respiratory Sensing and Gated Control for Autonomous Needle Insertion Via CT Bore Robotic Arm

Currently, CT-guided lung biopsy is a highly manual procedure requiring patient breath-holding, iterative manual needle insertions, and repeated CT confirmation scans to accurately target a tumor. Automating this process within the CT bore--without relying on manual needle placement or patient breath-holding--has the potential to reduce procedure time, patient discomfort, and radiation exposure. In this work, we present an integrated sensing and control system capable of performing a gated needle insertion within the CT bore. The experiments demonstrate the system's ability to track and predict patient breath cycles, perform autonomous respiratory-gated needle insertion, and detect breath cycle anomalies.

cs.RO↗

Dexterous Control of an 11-DOF Redundant Robot for CT-Guided Needle Insertion With Task-Oriented Weighted Policies

Computed tomography (CT)-guided needle biopsies are critical for diagnosing a range of conditions, including lung cancer, but present challenges such as limited in-bore space, prolonged procedure times, and radiation exposure. Robotic assistance offers a promising solution by improving needle trajectory accuracy, reducing radiation exposure, and enabling real-time adjustments. In our previous work, we introduced a robotic platform designed for accurate needle insertion within the confined CT bore. However, its performance in clinical settings is restricted by limited dexterity and a constrained workspace. In this study, we present an 11-degree-of-freedom (DOF) robotic system that integrates a 6-DOF robotic base with an improved 5-DOF cable-driven end-effector, yielding a significantly expanded workspace and enhanced dexterity. To leverage the hyper-redundant degrees of freedom, we introduce a weighted inverse kinematics controller, along with a null-space control strategy to optimize maneuverability and dexterity. By using a task-oriented weight matrix as a hyperparameter, the system provides a two-stage priority scheme fit for both large-scale movement and fine in-bore adjustments. In clinically relevant simulated scenarios, the system demonstrates a consistent 97% reachability rate across various human models. In addition, the task-oriented weight-matrix policy is extensively explored in five representative subtasks seen during needle biopsy through both simulation and real-world experiments, demonstrating superior tracking accuracy and enhanced manipulability for CT-guided procedures.

cs.RO↗

Computationally efficient cardiac views projection using 3D Convolutional Neural Networks

4D Flow is an MRI sequence which allows acquisition of 3D images of the heart. The data is typically acquired volumetrically, so it must be reformatted to generate cardiac long axis and short axis views for diagnostic interpretation. These views may be generated by placing 6 landmarks: the left and right ventricle apex, and the aortic, mitral, pulmonary, and tricuspid valves. In this paper, we propose an automatic method to localize landmarks in order to compute the cardiac views. Our approach consists of first calculating a bounding box that tightly crops the heart, followed by a landmark localization step within this bounded region. Both steps are based on a 3D extension of the recently introduced ENet. We demonstrate that the long and short axis projections computed with our automated method are of equivalent quality to projections created with landmarks placed by an experienced cardiac radiologist, based on a blinded test administered to a different cardiac radiologist.

cs.CV↗