arXiv Science⌕ Search

arXiv subjects

Adyaa Khera

Publications and source records attributed to Adyaa Khera.

2 recordsLinked to original sources

LuxTac: A Flexible, Scalable, and Open-Source Optical Taxel Array with Distributed Three-Axis Force Sensing for Tactile Robot Learning

Low-cost tactile arrays have made touch a practical input for robot learning, but piezoresistive designs sense only pressure, while camera-based sensors that also resolve shear are too bulky to tile over a gripper. To solve this problem, we present LuxTac, a flexible, scalable optical taxel array, about 3.5 mm thick and built from off-the-shelf parts. Each taxel is a digital RGBC light-to-digital converter under a translucent white silicone layer capped by an opaque black film, so the back-scattered LED light falls monotonically with local indentation depth. The same board accepts two interchangeable gel cartridges: a plain one for normal sensing, and one with colored walls that encodes the local shear in the color of the returned light, with no camera, magnets, or bump overlay, making LuxTac, to our knowledge, the first optical taxel array to resolve shear at individual taxels. Characterized with an automated CNC indenter and a six-axis force/torque sensor, the normal cartridge responds linearly to force ($R^2$ = 0.999) from 104 mN to at least 5.8 N, with 2.0% repeatability, 5.9% hysteresis, and a taxel-to-taxel variation of 6-10% after normalization. With the shear cartridge, per-taxel models estimate the three-axis force at every taxel; across three indenter shapes and nine held-out sessions, the summed estimates reach $R^2$ = 0.96/0.96/0.92 in x/y/z, each taxel's estimate 0.92/0.93/0.94, and the median shear-direction error is 4.8 degrees. Adding LuxTac pressure readings to an Action Chunking Transformer policy substantially improves peg-in-hole success over a vision-only baseline. Design files, code, and videos are available at https://luxtac.github.io.

cs.RO↗

MVP-Tac: A Miniaturized Dual-Modal Vision and Photoelastic Tactile Sensor for Robot-Assisted Minimally Invasive Surgery

Robot-assisted minimally invasive surgery (RMIS) offers major benefits over open and conventional laparoscopic procedures, yet it still lacks tactile feedback for palpation while operating under strict requirements to preserve reliable vision for navigation and safety. In practice, visual feedback is indispensable, and tactile solutions that cannot coexist with vision are difficult to translate into RMIS tools. To address both needs, we introduce MVP-Tac, a compact, vision-based tactile sensor that provides co-located vision and tactile sensing. MVP-Tac uses reflective photoelastic imaging: a thin photoelastic elastomer produces stress-dependent interferograms under contact that are captured by an embedded camera through a miniaturized reflective polariscope. A semi-transparent membrane and controllable illumination enable switching between visual mode and tactile mode, enabling tactile perception without sacrificing vision. We validate MVP-Tac through force calibration in the 0 to 2 N range and demonstrate its potential for tumor palpation via video-based hardness classification on tissue phantoms, achieving 97% accuracy for exposed-tumor classification and 92% accuracy for subdermal-tumor classification. Finally, we conduct a simulated colonoscopy to validate both visual and tactile modalities in a constrained lumen, including vision-guided 3D photomapping of the luminal wall and in situ hardness classification of localized nodules. Overall, MVP-Tac provides a practical path toward restoring clinically useful palpation in RMIS while maintaining essential visual feedback. The design, fabrication, and firmware of MVP-Tac are open-sourced at https://mvp-tac.github.io/

cs.RO↗