arXiv ScienceSearch

arXiv subjects

Adnan Armouti

Publications and source records attributed to Adnan Armouti.

4 recordsLinked to original sources

3D Point Splatting for mmWave Radar Novel View Synthesis

Solving novel view synthesis (NVS) for millimeter-wave (mmWave) radar requires a renderer that is physically faithful, complex-valued, and multi-viewpoint-tractable. No prior method achieves these three properties simultaneously. Differentiable Monte Carlo (MC) ray tracers implement the radar forward model directly with explicit material modeling and complex outputs, but do not scale to the multi-view optimization NVS demands. Optical-NVS ports of NeRF, hash grids, and 3D Gaussians train fast but discard phase and replace explicit material modeling with opaque learned features, restricting them to power-only range-azimuth (RA) magnitudes. We propose 3D Point Splatting (3DPS), the first differentiable point renderer for radar, derived directly from the standard solid-angle form of the radar equation. Each oriented 3D point carries an ITU-R P.2040 material model, evaluated in closed form, with the resulting complex phasor splatted into range bins through a precomputed point spread function (PSF). The complex-valued output makes the renderer product-agnostic. The same optimized scene yields analog-to-digital converter (ADC), complex range profile (CRP), and RA outputs through standard fast Fourier transform (FFT) pipelines without retraining for each format. On six outdoor ColoRadar scenes, 3DPS reaches 0.587 mean Pearson correlation on held-out RA images. This is between 1.7x and 5.2x the three optical-NVS baselines (RadarSplat, Radar Fields, DART). Training takes approximately 3 minutes per scene on a single RTX 4090.

cs.CV

mmIR: Frequency-Space Inverse Rendering for 3D Millimeter-Wave Radar ADC Synthesis

High-resolution 3D radar data is scarce. Commodity mmWave sensors use small antenna arrays that limit angular resolution to several degrees, and existing datasets provide only 2D range-azimuth maps or sparse point clouds rather than raw analog-to-digital converter (ADC) signals. Hardware scaling is expensive, synthetic-aperture scanning is impractical at fleet scale, and learned synthesis methods are bottlenecked by the very data shortage they aim to address. We present mmIR, an open-source differentiable frequency-modulated continuous-wave (FMCW) radar inverse renderer that fits a physics-based forward model to real captures and re-renders from dense virtual apertures to synthesize high-resolution 3D radar data. Because radar resolution is too coarse to recover geometry directly, mmIR performs LiDAR-assisted inverse rendering: using LiDAR-derived meshes as a geometric scaffold, mmIR optimizes per-vertex International Telecommunication Union (ITU) physics materials, vertex normals, and antenna beam patterns through end-to-end automatic differentiation of a phase-coherent multiple-input multiple-output (MIMO) forward model with multi-bounce propagation, polarization, and free-space diffraction. On seven outdoor and six indoor ColoRadar scenes, mmIR achieves 0.914 mean Pearson correlation on range-azimuth maps versus 0.307 for Sionna-RT. Scenes trained on a cascaded imaging radar transfer to a co-located single-chip radar without re-training (0.554 correlation), and dense virtual arrays (100x100 elements) produce single-frame 3D occupancy validated against LiDAR. Project page: https://mmwave-inverse-rendering.github.io/

cs.CV

mmFHE: mmWave Sensing with End-to-End Fully Homomorphic Encryption

We present mmFHE, the first system that executes the entire cloud-side mmWave sensing pipeline including the DSP and ML inference under fully homomorphic encryption (FHE). mmFHE encrypts range profiles on an edge device after lightweight plaintext preprocessing and executes the entire mmWave signal-processing and ML inference pipeline homomorphically on a semi-honest cloud that operates exclusively on ciphertexts. At the core of mmFHE is a library of seven composable, data-oblivious FHE kernels that replace standard DSP routines with fixed arithmetic circuits for different application-specific pipelines. We demonstrate this approach on two representative tasks: vital-sign monitoring and gesture recognition. We formally prove two cryptographic guarantees for any pipeline assembled from this library: input privacy and data obliviousness. These guarantees effectively neutralize various supervised and unsupervised privacy attacks on raw data, including re-identification and data-dependent privacy leakage. Evaluation on three public radar datasets shows that encryption introduces negligible error versus the plaintext pipeline, with 84.5% gesture accuracy (vs. 84.7%). End-to-end cloud GPU latency is 1.21 s per 10 s vital-sign window and 5.76 s per 3 s gesture window. These results establish the initial feasibility of end-to-end mmWave sensing under FHE on commodity hardware.

cs.CR

Thermal Imaging and Radar for Remote Sleep Monitoring of Breathing and Apnea

Polysomnography (PSG), the current gold standard method for monitoring and detecting sleep disorders, is cumbersome and costly. At-home testing solutions, known as home sleep apnea testing (HSAT), exist. However, they are contact-based, a feature which limits the ability of some patient populations to tolerate testing and discourages widespread deployment. Previous work on non-contact sleep monitoring for sleep apnea detection either estimates respiratory effort using radar or nasal airflow using a thermal camera, but has not compared the two or used them together. We conducted a study on 10 participants, ages 34 - 78, with suspected sleep disorders using a hardware setup with a synchronized radar and thermal camera. We show the first comparison of radar and thermal imaging for sleep monitoring, and find that our thermal imaging method outperforms radar significantly. Our thermal imaging method detects apneas with an accuracy of 0.99, a precision of 0.68, a recall of 0.74, an F1 score of 0.71, and an intra-class correlation of 0.70; our radar method detects apneas with an accuracy of 0.83, a precision of 0.13, a recall of 0.86, an F1 score of 0.22, and an intra-class correlation of 0.13. We also present a novel proposal for classifying obstructive and central sleep apnea by leveraging a multimodal setup. This method could be used accurately detect and classify apneas during sleep with non-contact sensors, thereby improving diagnostic capacities in patient populations unable to tolerate current technology.

cs.CV