arXiv ScienceSearch

arXiv subjects

Abbas Rabiu Muhammad

Publications and source records attributed to Abbas Rabiu Muhammad.

2 recordsLinked to original sources

NIMARC-MRI: Abdominal HASTE Dataset and a Baseline U-Net Exposing the Synthetic-to-Real Gap in Low-Resource Motion Correction

Respiratory motion degrades abdominal T2 HASTE MRI in low- and middle-income countries where vendor motion-correction licenses are unavailable and failed scans are deleted during routine PACS cleanup, precluding supervised training. To address this, we introduce NIMARC-MRI, the first public abdominal MRI dataset from West Africa, comprising 139 clean HASTE, 25 native motion-degraded HASTE, and 79 paired HASTE-TSE TRIGGER acquisitions from a Nigerian centre operating 1.5 T Siemens scanner without integrated motion-correction licenses. A 2D U-Net with 7.7 million parameters was trained on 3D-consistent synthetic respiratory motion necessitated by local infrastructure reality and validated via a three-tier strategy: held-out synthetic data, blinded radiologist Likert scoring on native real motion, and cross-sequence TRIGGER generalisation. On synthetic test data the model achieved SSIM 0.863 +/- 0.042 and PSNR 30.06 +/- 1.80 dB. On native real motion, however, blinded radiologist and radiographer scores showed no significant improvement (mean Likert 4.06 +/- 0.55 original versus 4.04 +/- 0.61 corrected, P = 0.914), with 28% of cases rated worse after correction. Cross-sequence TRIGGER evaluation showed modest SSIM improvement (0.404 +/- 0.073 versus 0.334 +/- 0.055, P < 0.001) without radiologist-perceived gain. These findings demonstrate that conservative synthetic motion fails to capture clinical motion severity, exposing a reproducible synthetic-to-real gap. NIMARC-MRI is released on Zenodo (https://doi.org) under a controlled data-use agreement requiring citation. Sequence metadata and a sample subset are publicly accessible to facilitate discovery, while patient-level data remain restricted to approved collaborators. The aim is to establish a reproducible baseline for motion correction in resource-constrained settings.

eess.IV

Resource-Efficient Glioma Segmentation on Sub-Saharan MRI

Gliomas are the most prevalent type of primary brain tumors, and their accurate segmentation from MRI is critical for diagnosis, treatment planning, and longitudinal monitoring. However, the scarcity of high-quality annotated imaging data in Sub-Saharan Africa (SSA) poses a significant challenge for deploying advanced segmentation models in clinical workflows. This study introduces a robust and computationally efficient deep learning framework tailored for resource-constrained settings. We leveraged a 3D Attention UNet architecture augmented with residual blocks and enhanced through transfer learning from pre-trained weights on the BraTS 2021 dataset. Our model was evaluated on 95 MRI cases from the BraTS-Africa dataset, a benchmark for glioma segmentation in SSA MRI data. Despite the limited data quality and quantity, our approach achieved Dice scores of 0.76 for the Enhancing Tumor (ET), 0.80 for Necrotic and Non-Enhancing Tumor Core (NETC), and 0.85 for Surrounding Non-Functional Hemisphere (SNFH). These results demonstrate the generalizability of the proposed model and its potential to support clinical decision making in low-resource settings. The compact architecture, approximately 90 MB, and sub-minute per-volume inference time on consumer-grade hardware further underscore its practicality for deployment in SSA health systems. This work contributes toward closing the gap in equitable AI for global health by empowering underserved regions with high-performing and accessible medical imaging solutions.

cs.CV