arXiv ScienceSearch

arXiv subjects

A. Nambu

Publications and source records attributed to A. Nambu.

3 recordsLinked to original sources

Neutron emission following nuclear muon capture on palladium isotopes

The energy spectra of the neutrons emitted following nuclear muon capture on palladium isotopes ($A=104$, 105, 106, 108, and 110) were measured using isotopically enriched target. \item[Method] The experiment was performed at the MuSIC-M1 beamline at the Research Center for Nuclear Physics (RCNP), Osaka University. The neutrons and $\gamma$ rays were detected with twenty-one liquid scintillators and BaF$_2$ detectors. The time-of-flight method was used to determine the neutron energy. \item[Results] Neutron energy spectra from 1\,MeV up to 20\,MeV were measured for five palladium isotopes, providing the first systematic data in the $A\sim100$ region. The spectral shapes were compared with the previous measurement for heavy nuclei and theoretical calculations. The neutron-neutron opening angle distribution was also measured and an indication of small angle correlation was found. \item[Conclusions] The spectral shape below 4\,MeV was well explained consistently with the previous measurement by the evaporation model introducing a mass number scaling. The neutron energy spectrum around 10\,MeV plays a key role in understanding the dynamics of the nuclear muon capture reaction because it is the result of the transition from the direct and pre-equilibrium neutron emission onto the evaporation process.

nucl-ex

Temperature-Dependent X-Ray Absorption Spectroscopy of Colossal Magnetoresistive Perovskites

The temperature dependence of the O K-edge pre-edge structure in the x-ray absorption spectra of the perovskites La(1-x)A(x)MnO(3), (A = Ca, Sr; x = 0.3, 0.4) reveals a correlation between the disappearance of the splitting in the pre-edge region and the presence of Jahn-Teller distortions. The different magnitudes of the distortions for different compounds is proposed to explain some dissimilarity in the line shape of the spectra taken above the Curie temperature.

cond-mat.str-el

Correction of non-linearity effects in detectors for electron spectroscopy

Using photoemission intensities and a detection system employed by many groups in the electron spectroscopy community as an example, we have quantitatively characterized and corrected detector non-linearity effects over the full dynamic range of the system. Non-linearity effects are found to be important whenever measuring relative peak intensities accurately is important, even in the low-countrate regime. This includes, for example, performing quantitative analyses for surface contaminants or sample bulk stoichiometries, where the peak intensities involved can differ by one or two orders of magnitude, and thus could occupy a significant portion of the detector dynamic range. Two successful procedures for correcting non-linearity effects are presented. The first one yields directly the detector efficiency by measuring a flat-background reference intensity as a function of incident x-ray flux, while the second one determines the detector response from a least-squares analysis of broad-scan survey spectra at different incident x-ray fluxes. Although we have used one spectrometer and detection system as an example, these methodologies should be useful for many other cases.

physics.ins-det