arXiv ScienceSearch

arXiv subjects

A. Grillo

Publications and source records attributed to A. Grillo.

At least 19 recordsLinked to original sources

Gas dependent hysteresis in MoS$_2$ field effect transistors

We study the effect of electric stress, gas pressure and gas type on the hysteresis in the transfer characteristics of monolayer molybdenum disulfide (MoS2) field effect transistors. The presence of defects and point vacancies in the MoS2 crystal structure facilitates the adsorption of oxygen, nitrogen, hydrogen or methane, which strongly affect the transistor electrical characteristics. Although the gas adsorption does not modify the conduction type, we demonstrate a correlation between hysteresis width and adsorption energy onto the MoS2 surface. We show that hysteresis is controllable by pressure and/or gas type. Hysteresis features two well-separated current levels, especially when gases are stably adsorbed on the channel, which can be exploited in memory devices.

cond-mat.mes-hall

The ASTRI Cherenkov Camera: from the prototype to the industrial version for the Mini-Array

The observation of energetic astronomical sources emitting very high-energy gamma-rays in the TeV spectral range (as e.g. supernova remnants or blazars) is mainly based on detecting the Cherenkov light induced by relativistic particles in the showers produced by the photon interaction with the Earth atmosphere. The ASTRI Mini-Array is an INAF-led project aimed observing such celestial objects in the 1 - 100 TeV energy range. It consists of an array of nine innovative imaging atmospheric Cherenkov telescopes that are an evolution of the dual-mirror aplanatic ASTRI-Horn telescope operating at the INAF "M.C. Fracastoro" observing station (Serra La Nave, Mount Etna, Italy). The ASTRI Mini-Array is currently under construction at the Observatorio del Teide (Tenerife, Spain). In this paper, we present the compact (diameter 660mm, height 520mm, weight 73kg) ASTRI-Horn prototype Cherenkov Camera based on a modular multipixel Silicon Photon Multiplier (SiPM) detector, has been acquiring data since 2016 and allowing us to obtain both scientific data and essential lessons. In this contribution, we report the main features of the camera and its evolution toward the new Cherenkov camera, which will be installed on each ASTRI Mini-Array telescope to cover an unprecedented field of view of 10.5{\deg}.

astro-ph.IM

Searching for Prompt and Long-Lived Dark Photons in Electro-Produced $e^+e^-$ Pairs with the Heavy Photon Search Experiment at JLab

The Heavy Photon Search experiment (HPS) at the Thomas Jefferson National Accelerator Facility searches for electro-produced dark photons. We report results from the 2016 Engineering Run consisting of 10608/nb of data for both the prompt and displaced vertex searches. A search for a prompt resonance in the $e^+e^-$ invariant mass distribution between 39 and 179 MeV showed no evidence of dark photons above the large QED background, limiting the coupling of {\epsilon}^2 {\geq} 10^-5, in agreement with previous searches. The search for displaced vertices showed no evidence of excess signal over background in the masses between 60 and 150 MeV, but had insufficient luminosity to limit canonical heavy photon production. This is the first displaced vertex search result published by HPS. HPS has taken high-luminosity data runs in 2019 and 2021 that will explore new dark photon phase space.

hep-ex

UVscope and its application aboard the ASTRI-Horn telescope

UVscope is an instrument, based on a multi-pixel photon detector, developed to support experimental activities for high-energy astrophysics and cosmic ray research. The instrument, working in single photon counting mode, is designed to directly measure light flux in the wavelengths range 300-650~nm. The instrument can be used in a wide field of applications where the knowledge of the nocturnal environmental luminosity is required. Currently, one UVscope instrument is allocated onto the external structure of the ASTRI-Horn Cherenkov telescope devoted to the gamma-ray astronomy at very high energies. Being co-aligned with the ASTRI-Horn camera axis, UVscope can measure the diffuse emission of the night sky background simultaneously with the ASTRI-Horn camera, without any interference with the main telescope data taking procedures. UVscope is properly calibrated and it is used as an independent reference instrument for test and diagnostic of the novel ASTRI-Horn telescope.

astro-ph.IM

Vacuum gauge from ultrathin MoS2 transistor

We fabricate monolayer MoS2 field effect transistors and study their electric characteristics from 10^-6 Torr to atmospheric air pressure. We show that the threshold voltage of the transistor increases with the growing pressure. Hence, we propose the device as an air pressure sensor, showing that it is particularly suitable as a low power consumption vacuum gauge. The device functions on pressure-dependent O2, N2 and H2O molecule adsorption that affect the n-doping of the MoS2 channel.

physics.app-ph

Electron irradiation of metal contacts in monolayer MoS$_2$ Field-Effect Transistors

This work deals with the electron beam irradiation of the Schottky metal contacts in monolayer molybdenum disulfide (MoS$_2$) field-effect transistors (FETs). We show that the exposure of the Ti/Au source/drain leads to an electron beam improves the transistor conductance. We simulate the path of the electrons in the device and show that most of the beam energy is absorbed in the metal contacts. Hence, we propose that the transistor current enhancement is due to thermally induced interfacial reactions that lower the contact Schottky barriers. We also show that the electron beam conditioning of contacts is permanent, while the irradiation of the channel can produce transient effects.

physics.app-ph

Electron irradiation on multilayer PdSe$_2$ field effect transistors

Palladium diselenide (PdSe2) is a recently isolated layered material that has attracted a lot of interest for the pentagonal structure, the air stability and the electrical properties largely tunable by the number of layers. In this work, PdSe2 is used in the form of multilayer as the channel of back-gate field-effect transistors, which are studied under repeated electron irradiations. Source-drain Pd leads enable contacts with resistance below 350 kOhm um. The transistors exhibit a prevailing n-type conduction in high vacuum, which reversibly turns into ambipolar electric transport at atmospheric pressure. Irradiation by 10 keV electrons suppresses the channel conductance and promptly transforms the device from n-type to p-type. An electron fluence as low as 160 e-/nm2 dramatically change the transistor behavior demonstrating a high sensitivity of PdSe2 to electron irradiation. The sensitivity is lost after few exposures, that is a saturation condition is reached for fluence higher than 4000 e-/nm2. The damage induced by high electron fluence is irreversible as the device persist in the radiation-modified state for several hours, if kept in vacuum and at room temperature. With the support of numerical simulation, we explain such a behavior by electron-induced Se atom vacancy formation and charge trapping in slow trap states at the Si/SiO_2 interface.

physics.app-ph

Field emission in ultrathin PdSe2 back-gated transistors

We study the electrical transport in back-gate field-effect transistors with ultrathin palladium diselenide (PdSe2) channel. The devices are normally-on and exhibit dominant n-type conduction at low pressure. The electron conduction, combined with the sharp edge and the workfunction decreasing with the number of layers, opens the way to applications of PdSe2 nanosheets in vacuum electronics. In this work, we demonstrate field emission from few-layer PdSe2 nanosheets with current up to the uA and turn-on field below 100 V/um, thus extending the plethora of applications of this recently isolated pentagonal layered material.

physics.app-ph

First detection of the Crab Nebula at TeV energies with a Cherenkov telescope in a dual-mirror Schwarzschild-Couder configuration: the ASTRI-Horn telescope

We report on the first detection of very high-energy (VHE) gamma-ray emission from the Crab Nebula by a Cherenkov telescope in dual-mirror Schwarzschild-Couder (SC) configuration. The result has been achieved by means of the 4 m size ASTRI-Horn telescope, operated on Mt. Etna (Italy) and developed in the context of the Cherenkov Telescope Array Observatory preparatory phase. The dual-mirror SC design is aplanatic and characterized by a small plate scale, allowing us to implement large field of view cameras with small-size pixel sensors and a high compactness. The curved focal plane of the ASTRI camera is covered by silicon photo-multipliers (SiPMs), managed by an unconventional front-end electronics based on a customized peak-sensing detector mode. The system includes internal and external calibration systems, hardware and software for control and acquisition, and the complete data archiving and processing chain. The observations of the Crab Nebula were carried out in December 2018, during the telescope verification phase, for a total observation time (after data selection) of 24.4 h, equally divided into on- and off-axis source exposure. The camera system was still under commissioning and its functionality was not yet completely exploited. Furthermore, due to recent eruptions of the Etna Volcano, the mirror reflection efficiency was reduced. Nevertheless, the observations led to the detection of the source with a statistical significance of 5.4 sigma above an energy threshold of ~3 TeV. This result provides an important step towards the use of dual-mirror systems in Cherenkov gamma-ray astronomy. A pathfinder mini-array based on nine large field-of-view ASTRI-like telescopes is under implementation.

astro-ph.IM

Characterization method to achieve simultaneous absolute PDE measurements of all pixels of an ASTRI Mini-Array camera tile

Recently, the Istituto Nazionale di Astrofisica (INAF) has placed a contract with Hamamatsu Photonics to acquire hundreds of Silicon Photomultipliers (SiPM) tiles to build 10 cameras with 37 tiles each for the ASTRI Mini-Array (MA) project. Each tile is made up of 8x8 pixels of 7x7 mm2 with micro-cells of 75um. To check the quality of the delivered tiles a complex and acurate test plan has been studied. The possibility to simultaneously analyse as many pixels as possible becomes of crucial im-portance. Dark Count Rate (DCR) versus over-voltage and versus temperature and Optical Cross Talk (OCT) versus over-voltage can be easily measured simultaneously for all pixels because they are carried out in dark conditions. On the contrary, simultaneous Photon Detection Efficiency (PDE) measurement of all pixels of a tile is not easily achievable and needs an appropriate optical set-up. Simultaneous measurements have the advantage of speeding up the entire procedure and enabling quick PDE compari-son of all the tile pixels. The paper describes the preliminary steps to guarantee an accurate absolute PDE measurement and the investigation the capa-bility of the electronics to obtain simultaneous PDE measurements. It also demonstrates the possibility of using a calibrated SiPM as reference detector instead of a calibrated photodiode. The method to achieve accurate absolute PDE of four central pixels of a tile is also described.

astro-ph.IM

Search for a Dark Photon in Electro-Produced $e^{+}e^{-}$ Pairs with the Heavy Photon Search Experiment at JLab

The Heavy Photon Search experiment took its first data in a 2015 engineering run using a 1.056 GeV, 50 nA electron beam provided by CEBAF at the Thomas Jefferson National Accelerator Facility, searching for an electro-produced dark photon. Using 1.7 days (1170 nb$^{-1}$) of data, a search for a resonance in the $e^{+}e^{-}$ invariant mass distribution between 19 and 81 MeV/c$^2$ showed no evidence of dark photon decays above the large QED background, confirming earlier searches and demonstrating the full functionality of the experiment. Upper limits on the square of the coupling of the dark photon to the Standard Model photon are set at the level of 6$\times10^{-6}$. In addition, a search for displaced dark photon decays did not rule out any territory but resulted in a reliable analysis procedure that will probe hitherto unexplored parameter space with future, higher luminosity runs.

hep-ex

Search for a Dark Photon in Electro-Produced $e^{+}e^{-}$ Pairs with the Heavy Photon Search Experiment at JLab

The Heavy Photon Search experiment took its first data in a 2015 engineering run at the Thomas Jefferson National Accelerator Facility, searching for a prompt, electro-produced dark photon with a mass between 19 and 81 MeV/$c^2$. A search for a resonance in the $e^{+}e^{-}$ invariant mass distribution, using 1.7 days (1170 nb$^{-1}$) of data, showed no evidence of dark photon decays above the large QED background, confirming earlier searches and demonstrating the full functionality of the experiment. Upper limits on the square of the coupling of the dark photon to the Standard Model photon are set at the level of 6$\times10^{-6}$. Future runs with higher luminosity will explore new territory.

hep-ex

Procedures for the relative calibration of the SiPM gain on ASTRI SST-2M camera

ASTRI SST-2M is one of the prototypes of the small size class of telescopes proposed for the Cherenkov Telescope Array. Its optical design is based on a dual-mirror Schwarzschild-Couder configuration, and the camera is composed by a matrix of monolithic multipixel silicon photomultipliers managed by ad-hoc tailored front-end electronics. This paper describes the procedures for the gain calibration on the ASTRI SST-2M. Since the SiPM gain depends on the operative voltage and the temperature, we adjust the operative voltages for all sensors to have equal gains at a reference temperature. We then correct gain variations caused by temperature changes by adjusting the operating voltage of each sensor. For that purpose the SiPM gain dependence on operating voltage and on temperature have been measured. In addition, we present the calibration procedures and the results of the experimental measurements to evaluate, for each pixel, the parameters necessary to make the trigger uniform over the whole focal plane.

astro-ph.IM

Characterization and performance of the ASIC (CITIROC) front-end of the ASTRI camera

The Cherenkov Imaging Telescope Integrated Read Out Chip, CITIROC, is a chip adopted as the front-end of the camera at the focal plane of the imaging Cherenkov ASTRI dual-mirror small size telescope (ASTRI SST-2M) prototype. This paper presents the results of the measurements performed to characterize CITIROC tailored for the ASTRI SST-2M focal plane requirements. In particular, we investigated the trigger linearity and efficiency, as a function of the pulse amplitude. Moreover, we tested its response by performing a set of measurements using a silicon photomultiplier (SiPM) in dark conditions and under light pulse illumination. The CITIROC output signal is found to vary linearly as a function of the input pulse amplitude. Our results show that it is suitable for the ASTRI SST-2M camera.

physics.ins-det

AtmoHEAD 2013 workshop / Atmospheric Monitoring for High-Energy Astroparticle Detectors

A 3-day international workshop on atmospheric monitoring and calibration for high-energy astroparticle detectors, with a view towards next-generation facilities. The atmosphere is an integral component of many high-energy astroparticle detectors. Imaging atmospheric Cherenkov telescopes and cosmic-ray extensive air shower detectors are the two instruments driving the rapidly evolving fields of very-high- and ultra-high-energy astrophysics. In these instruments, the atmosphere is used as a giant calorimeter where cosmic rays and gamma rays deposit their energy and initiate EASs; it is also the medium through which the resulting Cherenkov light propagates. Uncertainties in real-time atmospheric conditions and in the fixed atmospheric models typically dominate all other systematic errors. With the improved sensitivity of upgraded IACTs such as H.E.S.S.-II and MAGIC-II and future facilities like the Cherenkov Telescope Array (CTA) and JEM-EUSO, statistical uncertainties are expected to be significantly reduced, leaving the atmosphere as the limiting factor in the determination of astroparticle spectra. Varying weather conditions necessitate the development of suitable atmospheric monitoring to be integrated in the overall instrument calibration, including Monte Carlo simulations. With expertise distributed across multiple collaborations and scientific domains, an interdisciplinary workshop is being convened to advance progress on this critical and timely topic.

astro-ph.IM

The Site of the ASTRI SST-2M Telescope Prototype: Atmospheric Monitoring and Auxiliary Instrumentation

ASTRI is a Flagship Project led by the Italian National Institute of Astrophysics, INAF. The main objective of the ASTRI project is to develop a prototype of the Small Size class Telescope for the Cherenkov Telescope Array (CTA) in a dual-mirror configuration (SST-2M). The ASTRI SST-2M is an end-to-end prototype that will be fully developed by the ASTRI Collaboration from the optics design and manufacturing to the focal plane camera, from the structure of the mount to all the needed software. The ASTRI SST-2M prototype will be placed at the INAF "M.G. Fracastoro" observing station in Serra La Nave on the Etna Mountain near Catania, Italy. The technological solutions adopted will be tested on field: observations of the Crab Nebula and of other sources will be essential part of the science verification phase, with the aim to assess the achievement of the scientific requirements. In the following we present the Serra La Nave site together with all the auxiliary instruments needed for atmospheric monitoring and characterization, calibration and science verification of the ASTRI SST-2M prototype.

astro-ph.IM

Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier

These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.

hep-ex

Characterization of EASIROC as Front-End for the readout of the SiPM at the focal plane of the Cherenkov telescope ASTRI

The Extended Analogue Silicon Photo-multiplier Integrated Read Out Chip, EASIROC, is a chip proposed as front-end of the camera at the focal plane of the imaging Cherenkov ASTRI SST-2M telescope prototype. This paper presents the results of the measurements performed to characterize EASIROC in order to evaluate its compliance with the ASTRI SST-2M focal plane requirements. In particular, we investigated the trigger time walk and the jitter effects as a function of the pulse amplitude. The EASIROC output signal is found to vary linearly as a function of the input pulse amplitude with very low level of electronic noise and cross-talk (<1%). Our results show that it is suitable as front-end chip for the camera prototype, although, specific modifications are necessary to adopt the device in the final version of the telescope.

physics.ins-det