arXiv ScienceSearch

arXiv subjects

A. Grilli

Publications and source records attributed to A. Grilli.

3 recordsLinked to original sources

Fast IR Array Detector for Transverse Beam Diagnostics at DAΦNE

At the Laboratori Nazionali di Frascati of the National Institute of Nuclear Physics (INFN) an infrared (IR) array detector with fast response time has been built and assembled in order to collect the IR image of e-/e+ sources of the DAΦNE collider. Such detector is made by 32 bilinear pixels with an individual size of 50x50 μm2 and a response time of ~1 ns. In the framework of an experiment funded by the INFN Vth Committee dedicated to beam diagnostics, the device with its electronic board has been tested and installed on the DAΦNE positron ring. A preliminary characterization of few pixels of the array and of the electronics has been carried out at the IR beamline SINBAD at DAΦNE. In particular the detection of the IR source of the e- beam has been observed using four pixels of the array acquiring signals simultaneously with a four channels scope at 1 GHz and at 10 Gsamples/s. The acquisition of four pixels allowed monitoring in real time differences in the bunch signals in the vertical direction. A preliminary analysis of data is presented and discussed. In particular we will outline the correlation between signals and displacements of the source occurring with bunch refilling during a complete shift of DAΦNE.

physics.acc-ph

Beam diagnostics at DAFNE with fast uncooled IR detectors

Bunch-by-bunch longitudinal diagnostics is a key issue of modern accelerators. To face up this challenging demand, tests of mid-IR compact uncooled photoconductive HgCdTe detectors have been recently performed at DAFNE. Different devices were used to monitor the emission of e- bunches. The first experiments allowed recording of 2.7 ns long e- bunches with a FWHM of a single pulse of about 600 ps. These results address the possibility to improve diagnostics at DAFNE and to this purpose an exit port on a bending magnet of the positron ring has been set-up. An HV chamber, hosting a gold-coated plane mirror that collects and deflects the radiation through a ZnSe window, is the front-end of this port. After the window, a simple optical layout in air allows focusing IR radiation on different detectors. The instrumentation will allow comparison in the sub-ns time domain between the two rings and to identify and characterize bunch instabilities. Moreover, to improve performances tests of new photovoltaic detectors with sub-ns response times are in progress. We will briefly summarize the actual status of the 3+L experiment and will discuss future applications of fast IR photovoltaic detectors and the development of fast IR array detectors.

physics.acc-ph

Anisotropy of x-ray scattering in aligned nanotube structures

Effects of orientational x-ray scattering have been experimentally examined in a film of vertically aligned multiwall carbon nanotubes (CNs). Additional contribution to the x-ray fluorescence intensity was revealed at angles close to the film normal. Theoretical considerations suggest the intensity enhancement to be caused by propagation of C K$_α$-radiation mainly along the channels of CNs.

physics.optics