arXiv ScienceSearch

arXiv subjects

A. Giachero

Publications and source records attributed to A. Giachero.

At least 19 recordsLinked to original sources

Demonstrating the thermal noise limit in a backaction-free bulk acoustic wave resonator chain for gravitational wave detection

We report the full sub-Kelvin characterization of the BAUSCIA high-frequency gravitational-wave antenna, based on cryogenic Bulk Acoustic Wave resonators coupled to SQUID amplifiers for signal readout. The end-to-end performance analysis of the experimental chain, from the sensor to the DAQ, demonstrates that resonator thermal noise dominates the noise budget at temperatures well below 100 mK for all investigated modes. The measurements also verify proper thermalization of the resonator modes and rule out significant SQUID backaction on the strain sensor, confirming that the system operates close to its fundamental limits with comparable resonator thermal noise and additive readout noise. From this characterization, we derive projected strain sensitivities in the range $1$--$10 \times 10^{-21}\,\mathrm{Hz}^{-1/2}$ for several resonant frequencies between 5 and 20~MHz, with corresponding fundamental thermal limits in the range $0.7$--$1.4 \times 10^{-21}\,\mathrm{Hz}^{-1/2}$. Equipped with three resonators and synchronized to an absolute global time reference for multi-site coincidences, the antenna is ready to enter a pilot science run.

physics.ins-det

A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays

Massive cryogenic calorimeters read out by transition-edge sensors (TES) can reach eV-scale baseline resolution, but the single-channel dc-SQUID readout conventionally used in rare-event searches, with one amplifier chain and several wires per detector, limits practical arrays to a few tens of channels. We propose to apply microwave SQUID multiplexing ($μ$MUX), developed for fast X-ray and neutrino-mass microcalorimeters, to massive BGO (Bi$_4$Ge$_3$O$_{12}$) calorimeters operated at $\simeq 20$~mK; sapphire and TeO$_2$ absorbers are covered by the same framework. Using the established thermal and noise model for massive TES calorimeters, we derive a noise model for the multiplexed readout, including the HEMT, two-level-system and SQUID contributions, and its scaling with the multiplexing factor $N_{\rm mux}$. Since the slow thermal signals require only about a kHz of sampling per channel, the limiting requirement is not bandwidth but an input-coil sensitivity of $( 0.1$ to $1)\,μ$A$/Φ_0$, a factor of $10$ to $30$ beyond current $μ$MUX devices, matched to the detector current noise of ($9$ to $10$)~pA$/\sqrt{\rm Hz}$, which is independent of the absorber mass. With a total flux noise of $\simeq$$1.2\,μΦ_0/\sqrt{\rm Hz}$, the readout degrades the baseline resolution by less than $2\%$ up to $N_{\rm mux}=1000$, negligible compared with the TES-limited resolution. These results are implemented in a single-tower design: 52 BGO crystals of 100~g each and one HEMT amplifier. The tower is the unit of a multi-tower array of several kilograms aimed at CE$ν$NS and dark matter searches.

physics.ins-det

Probing dark matter interactions with a RES-NOVA prototype cryogenic detector

We report on the operation of a 13 g PbWO$_4$ crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO$_4$ as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES-NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES-NOVA detection concept, validating the use of archaeological Pb-based PbWO$_4$ crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES-NOVA detectors employing larger target masses and advanced thermal readout technologies.

physics.ins-det

Probing large mass-splitting inelastic Dark Matter with RES-NOVA

Probing inelastic dark matter at large mass splittings requires heavy target nuclei, an extended recoil-energy range, and the high-velocity tail of the dark-matter distribution. We exploit these features with the RES-NOVA prototype detector, featuring a PbWO4 cryogenic calorimeter, produced from archaeological Pb and operated at the deep-underground laboratory of Gran Sasso of INFN (Italy), analyzing a 32.4 g day exposure over 2.5 keV - 1 MeV under both the Standard Halo Model (SHM) and a Large Magellanic Cloud (LMC)-motivated velocity distribution. We extend direct-detection constraints beyond the 330 keV reach of established technologies (e.g. Xe-based TPCs), probing splittings up to 510 (780) keV in the SHM (LMC) benchmark, while future exposures will probe new regions of the parameter space.

astro-ph.CO

Demonstration of a cryogenic, switchable electron source for low-temperature detector calibration

We present the realization of a prototype of a compact, switchable electron source operating at cryogenic temperatures, demonstrated at energies ranging from 100 eV to 300 eV, and conceptually extendable to an arbitrary energy range. The electrons are produced via photoelectric emission, induced by a LED illuminating two 400~nm-thick commercial aluminum layers inside a cryostat, and are subsequently accelerated by a voltage of up to 300~V. Detection is carried out with an array of transition-edge sensor (TES) microcalorimeters designed for X-ray detectors, where we successfully observe signals consistent with electrons produced at the source at rates of $\gtrsim$1~Hz and with an efficiency of $\gtrsim 10^{-14}\ e^-/γ$. One of the potential applications of this prototype is the development of a calibration method for cryogenic detectors, based on the generation, acceleration, and multiplication of electrons, followed by their conversion into high-energy photons.

physics.ins-det

Solar axion searches with RES-NOVA: projected sensitivity and first prototype limit

RES-NOVA is a cryogenic experiment based on PbWO4 scintillating bolometers produced from archaeological lead, originally designed to detect coherent elastic neutrino-nucleus scattering (CEvNS) from galactic core-collapse supernovae. We show that the same high-density, high-Z absorbers and sub-keV energy resolution make RES-NOVA an appealing probe of solar axions. We compute the expected signal from the Primakoff, ABC (atomic recombination and de-excitation, Bremsstrahlung, Compton), longitudinal-plasmon (LP), and 57Fe nuclear-line components of the solar axion flux, folded through the inverse-Primakoff and axioelectric detection channels in PbWO4, which probe the axion couplings to photons (g_a-gamma), electrons (g_ae), and nucleons (g_aN), respectively. We derive projected sensitivities for a 1 ton*y exposure of the RES-NOVA demonstrator in the (g_ae,g_a-gamma), (g_ae,g_aN), and (g_a-gamma,g_aN) planes. The projected reach in g_ae approaches that of XENONnT to within a factor of ~2, despite a background roughly four orders of magnitude higher, thanks to the large target mass, the high-Z enhancement of the axioelectric and inverse-Primakoff cross sections, and the sub-keV energy resolution. Because the inverse-Primakoff constraint on g_a-gamma relies on absorption rather than coherent conversion, it is independent of the axion mass, unlike bounds from magnetic helioscopes. We complement these projections with the first solar-axion exclusion limit obtained on real data with a 13 g PbWO4 prototype grown from archaeological lead, using a background-model-independent optimum-interval analysis. These results establish RES-NOVA as a promising multi-coupling probe of solar axions, with simultaneous sensitivity to g_ae, g_a-gamma and g_aN that is complementary to existing helioscope and direct-detection searches.

hep-ex

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta ($0νββ$) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the {\it Laboratori Nazionali del Gran Sasso}, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation $0νββ$ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

physics.ins-det

Neutrino NSI in archaeological Pb

Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO$_4$ crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton$\cdot$y, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar $ν$ interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to $0.5$ keV and $0.2$ keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, $\varepsilon_{ee}$, $\varepsilon_{ττ}$, and $\varepsilon_{eτ}$. A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton$\cdot$y.

hep-ph

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0νββ$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0νββ$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0νββ$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

physics.ins-det

Phenomenological Modeling of the $^{163}$Ho Calorimetric Electron Capture Spectrum from the HOLMES Experiment

We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of $^{163}$Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing $^{163}$Ho, supporting both data analysis and experimental design.

nucl-ex

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data taking conditions. We achieve an average baseline resolution of 2.54 $\pm$ 0.14 keV FWHM and 1.18 $\pm$ 0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06 $\pm$ 0.05 counts/(keV kg days) and 16 $\pm$ 2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 26 $\pm$ 4 \% and 50 $\pm$ 2 \% at 3 keV and 10 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that tonne-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

hep-ex

Sensitivity of the CUPID experiment to $0νββ$ decay of $^{100}$Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo using Li$_2$MoO$_4$ scintillating crystals. It will operate 1596 crystals at $\sim$10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for $α$ rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0νββ$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \mathrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{ββ} < \ 9.6$ -- $28 \ \mathrm{meV}$. The Frequentist discovery sensitivity (3$σ$) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \mathrm{yr}$, corresponding to $\hat{m}_{ββ}= \ 12$ -- $36 \ \mathrm{meV}$.

nucl-ex

End-to-End Data Analysis Methods for the CUORE Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta ($0νββ$) decay half-life of $^{130}$Te with 2 ton yr TeO$_2$ analyzed exposure. In addition to $0νββ$ decay, the CUORE detector -- a ton-scale array of nearly 1000 cryogenic calorimeters operating at $\sim$10 mK -- is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for $0νββ$ decay.

nucl-ex

Constraints on Lepton Number Violation with the 2 tonne$\cdot$yr CUORE Dataset

Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay ($0νββ$) may help explain this asymmetry, while unveiling the Majorana nature of the neutrino. The CUORE experiment searches for $0νββ$ of $^{130}$Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of $0νββ$ and place a lower limit on the half-life of $T_{1/2} >3.5 \times$ 10$^{25}$~years (90\% C.I.) with over 2~tonne$\cdot$year TeO$_2$ exposure. The tools and techniques developed for this result and the 5 year stable operation of nearly 1000 detectors demonstrate crucial infrastructure for a future-generation experiment capable of searching for $0νββ$ across multiple isotopes.

nucl-ex

Coherent oscillations in weakly anharmonic NbSe2 qubit

The functionalization of quantum devices to increase their performance and extend their fields of application is an extremely active research area. One of the most promising approaches is to replace aluminum with more performant materials. Within this context, van der Waals (vdW) materials are ideal candidates since they would allow to embed their unique properties into qubits. However, the realization of qubits based on vdW materials other than graphene is yet to be achieved. In this work we present a weakly anharmonic NbSe2 qubit. Our device exhibits a relaxation time T1 = 6.5 +\- 0.4 us which is roughly 2 orders of magnitude larger of other vdW qubits in addition to robustness to photon noise up to 5-10 thermal photons. Our work serves as a demonstrator of the advantage of integration of vdW materials into quantum technologies as well as serving as the first step toward the application of quantum non demolition photon detection protocols in the challenging field of dark matter search.

quant-ph

Most stringent bound on electron neutrino mass obtained with a scalable low temperature microcalorimeter array

The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the Standard Model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. In this Letter, we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of $^{163}$Ho. The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of $7\times10^7$ decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of $m_β<27$ eV/c$^2$ at 90% credibility. These results validate the feasibility of $^{163}$Ho calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.

hep-ex

Synthetic-lattice Bloch wave dynamics in a single-mode microwave resonator

Frequency-based synthetic dimensions are a promising avenue for expanding the dimensionality of photonic systems. In this work, we show how a tilted synthetic lattice is naturally realised by periodically modulating a single-mode resonator under a coherent monochromatic drive. We theoretically study the Bloch wave dynamics in the tilted synthetic lattice, which gives rise to peculiar features in the spectral distribution of the cavity field. Our predictions are experimentally confirmed using a planar tunable superconducting microwave resonator.

cond-mat.mes-hall

CUPID, the CUORE Upgrade with Particle IDentification

CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10$^{-4}$ cnts/(keV$\cdot$kg$\cdot$yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90\% C.L. half-life exclusion sensitivity of 1.8 $\cdot$ 10$^{27}$ yr, corresponding to an effective Majorana neutrino mass ($m_{ββ}$) sensitivity of 9--15 meV, and a $3σ$ discovery sensitivity of 1 $\cdot$ 10$^{27}$ yr, corresponding to an $m_{ββ}$ range of 12--21 meV.

physics.ins-det