arXiv Science⌕ Search

arXiv · physics/9712029

Space-Time Approach to Scattering from Many Body Systems

Abstract

We present scattering from many body systems in a new light. In place of the usual van Hove treatment, (applicable to a wide range of scattering processes using both photons and massive particles) based on plane waves, we calculate the scattering amplitude as a space-time integral over the scattering sample for an incident wave characterized by its correlation function which results from the shaping of the wave field by the apparatus. Instrument resolution effects - seen as due to the loss of correlation caused by the path differences in the different arms of the instrument are automatically included and analytic forms of the resolution function for different instruments are obtained. The intersection of the moving correlation volumes (those regions where the correlation functions are significant) associated with the different elements of the apparatus determines the maximum correlation lengths (times) that can be observed in a sample, and hence, the momentum (energy) resolution of the measurement. This geometrical picture of moving correlation volumes derived by our technique shows how the interaction of the scatterer with the wave field shaped by the apparatus proceeds in space and time. Matching of the correlation volumes so as to maximize the intersection region yields a transparent, graphical method of instrument design. PACS: 03.65.Nk, 3.80 +r, 03.75, 61.12.B

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R. Gaehler, J. Felber, F. Mezei, R. Golub. 1997-12-16. Space-Time Approach to Scattering from Many Body Systems. https://doi.org/10.1103/physreva.58.280

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Nonperturbative regime of low-order harmonic generation in intense low-frequency laser field

We find the atomic response to the intense femtosecond laser pulse via solving numerically the three-dimensional non-stationary Schrödinger equation (TDSE) for a model atom and calculating its dipole moment. For weak quasi-static fields, the response is well described by a perturbation approach, but for intensities higher than about $0.6 \, \, 10^{14}$ W/cm$^2$ the accuracy of this description is unsatisfactory, regardless of the order of non-linearity taken into account. We suggest fitting the numerical TDSE solution results with a Padé expansion, and show that this approximation describes the response well both in the perturbative regime and beyond it for intensities approximately up to $1.4 \, \, 10^{14}$ W/cm$^2$. To consider the non-perturbative nonlinearity beyond the quasi-static limit we use the model of nonlinear oscillator with the restoring force defined by the found Padé expression. Our model fails to predict the behaviour of the nonlinear refractive index in the nonperturbative domain, but it describes well the nonperturbative growth of the efficiency with the laser intensity for other nonlinear optical processes, namely, the third and fifth harmonic generation in the IR field and the optical rectification in a two-color field.

physics.optics↗

Digitally enhanced Multi-wavelength Stabilization using a Passive Fiber Frequency Reference

High-stability frequency stabilization between lasers is essential for applications such as precision metrology, frequency dissemination, and quantum communications. We demonstrate the use of code-based multiplexing of a passive fiber-based interferometer for frequency stabilization and transfer between lasers separated by 85 GHz in frequency using a single shared passive reference. Out-of-loop characterization places an upper bound of sub-kHz/$\sqrt{\text{Hz}}$ on the transferred frequency noise at Fourier frequencies above 40 mHz, with a differential fractional stability of $7\times10^{-13}$ at 1 second. We also demonstrate continuous laser tunability and characterize the residual length noise coupling. Finally, we provide a framework for scaling the architecture to higher laser counts, offering a pathway to scalable, frequency agile stabilization of multiple light sources without the overhead of an optical frequency comb.

physics.optics↗

Optical Coherent Combining in Multi-Aperture Free-Space Receivers through Atmospheric Turbulence via Optically Computed Alignment Gradients

Multi-aperture reception yields a coherent-combining gain only if the aperture fields are aligned in phase and polarization, which in a downlink must track the atmosphere. We show that the exact gradients of the combined power with respect to the phase and polarization angle of each branch can be measured optically, before photodetection: a passive tap of the combined field, split one-to-$N$, is the common self-reference and, interfered with a branch tap on a 3 dB coupler, yields the phase gradient; with a $90^\circ$ Faraday rotator and a static $π/2$ offset it yields the polarization gradient. Each branch then runs fixed-gain phase and polarization loops, without division, perturbation, dither, reference laser, or per-branch receiver, as analog integrators or a low-rate processor. We derive the gradients, their optical readout, and the loop stability condition. A phase-only simulation with identical disturbances, a common 100 MS/s clock, and retuning of every scheme compares the loop with centralized and distributed stochastic parallel gradient descent and with dither locking at the OSNR where ideal four-beam combining reaches the 28 GBd DP-QPSK FEC threshold. Up to $10^5$ rad/s of multi-tone disturbance the loop keeps the lowest residual loss, at most $5.6\times10^{-4}$ dB for four beams and 13 to 160 times below the alternatives, and reaches $90\%$ efficiency in 0.6 $μ$s for up to 64 beams. The taps leave the receiver OSNR unchanged and every retuned scheme stays within 0.06 dB of ideal combining, whereas brief dither misalignments cost 0.14 dB. Up to $10^7$ rad/s it preserves the ideal-combining bit-error ratio for four, sixteen, and sixty-four beams while every baseline crosses the threshold and slips carrier recovery. In fades it loses $4\times10^{-3}$ dB where the others lose 0.2 to 0.9 dB. Assumptions and limitations are stated; experimental validation remains open.

physics.optics↗