arXiv · physics/0607229
Secondary Beam Monitors for the NuMI Facility at FNAL
Abstract
The Neutrinos at the Main Injector (NuMI) facility is a conventional neutrino beam which produces muon neutrinos by focusing a beam of mesons into a long evacuated decay volume. We have built four arrays of ionization chambers to monitor the position and intensity of the hadron and muon beams associated with neutrino production at locations downstream of the decay volume. This article describes the chambers' construction, calibration, and commissioning in the beam.
Explore related subjects
Keep this discovery
S. Kopp, M. Bishai, M. Dierckxsens, M. Diwan, A. R. Erwin, D. A. Harris, D. Indurthy, R. Keisler, M. Kostin, M. Lang, J. MacDonald, A. Marchionni, S. Mendoza, J. Morfin, D. Naples, D. Northacker, Z. Pavlovic, L. Phelps, H. Ping, M. Proga, C. Vellissaris, B. Viren, R. Zwaska. 2006-07-26. Secondary Beam Monitors for the NuMI Facility at FNAL. https://doi.org/10.1016/j.nima.2006.07.062
Cite the original work for its findings. Save a collection to share your selection of sources.