arXiv Science⌕ Search

arXiv · physics/0607191

Neutron imaging with a Micromegas detector

Abstract

The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a 1D Micromegas prototype. The number of pillars supporting the micromesh is too large and leads to local losses of efficiency that distort the tomographic reconstruction. Nevertheless, this first tomographic image achieved with this kind of detector is very encouraging. The next worthwhile development for neutron imaging is to achieve a bi-dimensional detector, which is presented in the second part of this study. The purpose of measurements was to investigate various operational parameters to optimize the spatial resolution. Through these measurements the optimum spatial resolution has been found to be around 160 microns (standard deviation) using Micromegas operating in double amplification mode. Several 2D imaging tests have been carried out. Some of these results have revealed fabrication defects that occurred during the manufacture of Micromegas and that are limiting the full potential of the present neutron imaging system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F. Jeanneau, R. Junca, J. Pancin, M. Voytchev, S. Andriamonje, V. Dangendorf, I. Espagnon, H. Friedrich, A. Giganon, I. Giomataris, A. Menelle, A. Pluquet, L. R. Rodriguez. 2006-07-21. Neutron imaging with a Micromegas detector. https://doi.org/10.1109/tns.2006.870175. https://arxiv.science/abs/physics/0607191

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Improved Pion-Kaon Identification in Heavy-Ion Collisions with a Two-Dimensional Transformation

Accurate identification of charged pions and kaons is essential for precision measurements in relativistic heavy-ion collisions, but becomes increasingly challenging at intermediate and high transverse momentum because of the increasing overlap of the TPC and TOF particle identification responses. In this work, we quantitatively benchmark a two-dimensional shift-and-rotation PID procedure that combines the $nσ_π$ and mass-squared $(m^{2})$ information. The benchmark is performed using Au+Au collision events generated with the AMPT model, where the detector response is modeled using $p_{T}$-dependent PID parameters extracted from STAR data. Since the true particle identities and input yields are known in AMPT but are not used during the reconstruction, the procedure can be evaluated through a direct closure test that is not possible with experimental data alone. The two-dimensional procedure is compared with a reference one-dimensional method consisting of an $|nσ_π|<$ 3 preselection followed by a Gaussian fit to the $m^{2}$ distribution. While both methods perform well when pion and kaon PID responses are well separated, the two-dimensional procedure provides improved yield closure as the PID distributions increasingly overlap at high $p_{T}$. The reconstructed-to-input yield ratio remains within 2\% of unity up to $p_T =$ 3 GeV/$c$, whereas the reference one-dimensional procedure shows a larger deviation. Reaction-plane $v_{2}$ closure tests show that both the reference one-dimensional and two-dimensional PID procedures reproduce the AMPT input $v_{2}$ within the statistical uncertainties over the studied $p_{T}$ range. These results demonstrate that the two-dimensional procedure substantially improves the high-$p_{T}$ yield reconstruction without introducing a detectable bias in the extracted $v_{2}$ under the STAR-like detector response considered here.

physics.ins-det↗

Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings

Optical coatings with minimal thermal noise are essential for high-precision, laser-based metrology experiments. Substrate-transferred crystalline GaAs/Al$_{0.92}$Ga$_{0.08}$As coatings have the lowest thermal noise for high-reflectivity mirror coatings with $λ=900$ nm -- 12 $μ$m. Time-frequency stabilization experiments have demonstrated that GaAs/AlGaAs mirror coatings have a lower noise floor than amorphous mirror coatings. These mirrors are now being developed at sizes $\ge 300$ mm for gravitational-wave detectors. In order to understand the coating's fundamental loss mechanisms, which cause thermal noise, we have performed the first measurement of the mechanical loss at cryogenic temperatures using a cryogenic, multimodal, gentle nodal suspension system, which operates from 12 K to room temperature. This initial measurement used a silicon substrate whose asymmetry produced excess friction with the nodal support. Accounting for this friction and Akhiezer loss in the substrate and coating, the mechanical loss agrees well with the thermal noise observed in experiments using cryogenic fixed-cavities with GaAs/AlGaAs mirrors.

physics.ins-det↗

Rotating Capacitive System for Measurement of a Third Order Gravity Gradient Based on a Single-Axis Mechanical Oscillator. Part I, Theory

This paper is a feasibility study on a single-axis mechanical oscillator, mounted on a miniature circular rotating platform, that is proposed to be used for measuring a quantity proportional to the second vertical derivative of gravitational acceleration projected onto the oscillator's sensitivity axis. The latter is aligned with the axis of rotation. Part I establishes theoretical feasibility only. Design constraints, quantitative sensitivity, error budgets, and mobile platform performance will be addressed in Part II.

physics.ins-det↗