arXiv Science⌕ Search

arXiv · physics/0606145

Prediction of tissue decompression in orbital surgery

Abstract

Objective: A method to predict the relationships between decompressed volume of orbital soft tissues, backward displacement of globe after osteotomy, and force exerted by the surgeon, was proposed to improve surgery planning in exophthalmia reduction. Design: A geometric model and a poroelastic finite element model were developed, based on Computed Tomography scan data. Background: The exophthalmia is characterised by a protrusion of the eyeball. Surgery consists in an osteotomy of the orbit walls to decompress the orbital content. A few clinical observations ruling on an almost linear relationship between globe backward displacement and tissue decompressed volume are described in the literature. Methods: Fast prediction of decompressed volume is derived from the geometric model: a sphere in interaction with a cone. Besides, a poroelastic Finite Element model involving morphology, material properties of orbital components and surgical gesture was implemented. Results: The geometric model provided a better decompression volume estimation than the Finite Element model. Besides, the Finite Element model permitted to quantify the backward displacement, the surgical gesture and the stiffness of the orbital content. Conclusions: The preliminary results obtained for one patient, in accordance with the clinical literature, were relatively satisfying. An efficient aid for location and size of osteotomies was derived and seemed to be able to help in the surgery planning. Relevance: To our knowledge, this paper concerns the first biomechanical study of exophthalmia reduction. The approach permitted to improve the treatment of orbitopathy and can be used in a clinical setting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Vincent Luboz, Annaig Pedrono, Dominique Ambard, Franck Boutault, Yohan Payan, Pascal Swider. 2006-06-16. Prediction of tissue decompression in orbital surgery. https://arxiv.org/abs/physics/0606145

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction

High-resolution three-dimensional (3-D) medical latent diffusion remains limited by the cost of decoding full volumes, which existing latent autoencoders (AEs) handle through overlapping sub-volume decoding. We propose a continuous 3-D latent diffusion model framework for computed tomography (CT) and magnetic resonance imaging (MRI) generation and measurement-guided reconstruction, built on a coordinate-rendering autoencoder (CoRe-AE). Its decoder applies its convolutional stage once on the compact latent grid and renders voxel intensities from spatial coordinates through a lightweight implicit head, evaluated in memory-bounded chunks. This design avoids overlapping sub-volumes and remains differentiable with respect to the latent, so that the decoder can be used inside measurement-guided reconstruction. The framework was evaluated on CT volumes of 512\textsuperscript{3} voxels and MRI volumes of 256\textsuperscript{3} voxels. At 512\textsuperscript{3}, the decoder was 4--18 times faster than the MAISI and 3D MedDiffusion AEs and required the lowest peak graphics processing unit (GPU) memory, including when its gradient was computed. CoRe-AE also achieved the highest peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) among the evaluated AEs on both modalities. The resulting frozen 3-D latent prior generated full volumes without patch seams and, without retraining, reconstructed sparse-view CT and accelerated MRI through hard data consistency, within 2.4--4.9 dB PSNR of the pixel-domain decomposed diffusion sampler (DDS). A single volumetric latent prior thus supports both generation and reconstruction of high-resolution medical volumes on one GPU. Our code and pretrained weights are available at https://github.com/Mellak/continuous-3d-latent-diffusion.

physics.med-ph↗

Dual-energy cardiac DSA imaging using a dual-layer flat-panel detector: in vivo validation study

Background: The temporal misregistration in conventional X-ray digital subtraction angiography (DSA) remains a key challenge for its practical application in cardiac catheterization, leading to incomplete separation of cardiac vessels from background anatomical structures. Purpose: In this study, the X-ray spectral information is unveiled for DSA imaging to generate better visualization of cardiac vessels with negligible anatomical background. Methods: A dedicated dual-energy DSA imaging model is proposed based on the subtraction residuals between pre-contrast and post-contrast spectral projections, enabling accurate material decomposition without requiring precise scatter correction. Specifically, a dual-layer flat-panel detector (DL-FPD) is assumed to acquire the needed temporally registered low-energy and high-energy projections. Moreover, a penalized likelihood material decomposition algorithm is proposed to enhance the material decomposition performance. To validate, in vivo swine experiments were conducted for the first time on a clinical DSA system equipped with a DL-FPD. Results: Monte Carlo simulation results demonstrated that the impact of scatter on the subtraction residuals can be reduced by more than 80%, substantially improving material decomposition accuracy. Compared with analytical material decomposition, the penalized-likelihood material decomposition algorithm significantly improves image contrast-to-noise ratio (CNR), enabling the visualization of small vessels and even the myocardial blush effect. Furthermore, compared with conventional dual-energy subtraction, the penalized-likelihood approach provides more quantitative material maps with fewer overlapping anatomical background artifacts. Conclusion: This preliminary study verifies that dual-energy DSA imaging method is able to generate high-quality cardiovascular imaging results.

physics.med-ph↗

Smart Spectral Doppler Ultrasound Imaging using Motion Tracking based on Wide-beam transmission and Neural Networks: Preliminary Results

Ultrasound spectral Doppler imaging provides quantitative blood flow information for vascular diagnosis, but its accuracy is limited by the one-dimensional (1D) sample volume (SV). Motion from respiration, patient movement, and probe manipulation can move the target vessel out of the SV, causing spectral broadening, signal reduction, or loss of the spectrum. A two-dimensional (2D) SV can address this, but sequential focused-beam transmission reduces the pulse-repetition frequency (PRF), and plane-wave transmission lowers the signal-to-noise ratio (SNR). In this study, we propose a wide-beam transmission method that acquires a 2D SV from a single transmit event while preserving the PRF. A Hamming network, which requires no prior training, tracks axial and lateral motion within the 2D SV and updates the position of an adaptive 1D SV for each frame. Field II simulations showed that the wide-beam transmission had a spectral SNR comparable to that of focused-beam transmission and approximately 10 dB higher than that of plane-wave transmission. The motion tracking correctly detected the target position in over 93% of frames for vessel radii greater than 1 mm, and in 100% of frames for radii greater than 2 mm. In vivo studies of a carotid artery (linear array) and a hepatic vein (convex array) showed that the proposed method recovered obscured spectra and increased the spectral SNR by 9.3 dB and 4.5 dB, respectively. These results demonstrate that the proposed wide-beam transmission with Hamming network-based tracking can improve the accuracy of spectral Doppler imaging under tissue motion. Moreover, we anticipate that the proposed approach can be implemented in real-time due to its single transmission and simple two-layer architecture with low computational complexity.

physics.med-ph↗