arXiv · physics/0410103
Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements
Abstract
Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of applied voltages. Double-gap DRPCs have demonstrated the MIP registration efficiency of 97% and the time resolution of 180-200 ps. No changes in DRPC operation have been observed with test beam intensities up to 10^3 Hz/cm^2.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
A. Akindinov, V. Golovin, A. Martemiyanov, V. Petrov, A. Smirnitskiy, K. Voloshin. 2004-12-02. Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements. https://arxiv.org/abs/physics/0410103
Cite the original work for its findings. Save a collection to share your selection of sources.