arXiv ScienceSearch

arXiv · astro-ph/0402580

Design and Calibration of a Cryogenic Blackbody Calibrator at Centimeter Wavelengths

Abstract

We describe the design and calibration of an external cryogenic blackbody calibrator used for the first two flights of the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) instrument. The calibrator consists of a microwave absorber weakly coupled to a superfluid liquid helium bath. Half-wave corrugations viewed 30 deg off axis reduce the return loss below -35 dB. Ruthenium oxide resistive thermometers embedded within the absorber monitor the temperature across the face of the calibrator. The thermal calibration transfers the calibration of a reference thermometer to the flight thermometers using the flight thermometer readout system. Data taken near the superfluid transition in 8 independent calibrations 4 years apart agree within 0.3 mK, providing an independent verification of the thermometer calibration at temperatures near that of the cosmic microwave background.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A. Kogut, E. Wollack, D. J. Fixsen, M. Limon, P. Mirel, S. Levin, M. Seiffert, P. M. Lubin. 2004-02-24. Design and Calibration of a Cryogenic Blackbody Calibrator at Centimeter Wavelengths. https://doi.org/10.1063/1.1821622

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

On binary pulsars and the force of gravity

The energy-momentum budget of the astrophysical systems can be studied by the exact local conservation equation derived by Landau and Lifshitz. We show that a similar equation is valid for the Einstein-Cartan gravity. We reanalyze a binary pulsar system using the Landau-Lifshitz conservation equation and show that the orbital period change rate can be completely understood as a curvature backreaction process. Taking into account the detailed theoretical and observational research of relativistic binary pulsar systems, especially the system of Hulse and Taylor, we conclude that general relativity and astrophysical observations rule out the existence of gravitational radiation. We comment upon the LIGO GW events and their alternative explanation, as well as the recent pulsar timing arrays data.

astro-ph

Oscillation frequencies and mode lifetimes in alpha Centauri A

We analyse our recently-published velocity measurements of alpha Cen A (Butler et al. 2004). After adjusting the weights on a night-by-night basis in order to optimize the window function to minimize sidelobes, we extract 42 oscillation frequencies with l=0 to 3 and measure the large and small frequency separations. We give fitted relations to these frequencies that can be compared with theoretical models and conclude that the observed scatter about these fits is due to the finite lifetimes of the oscillation modes. We estimate the mode lifetimes to be 1-2 d, substantially shorter than in the Sun.

astro-ph

Hipparcos period-luminosity relations for Miras and semiregular variables

We present period-luminosity diagrams for nearby Miras and semiregulars, selecting stars with parallaxes better than 20 per cent and well-determined periods. Using K-band magnitudes, we find two well-defined P-L sequences, one corresponding to the standard Mira P-L relation and the second shifted to shorter periods by a factor of about 1.9. The second sequence only contains semiregular variables, while the Mira sequence contains both Miras and semiregulars. Several semiregular stars show double periods in agreement with both relations. The Whitelock evolutionary track is shown to fit the data, indicating that the semiregulars are Mira progenitors. The transition between the two sequences may correspond to a change in pulsation mode or to a change in the stellar structure. Large amplitude pulsations leading to classical Mira classification occur mainly near the tip of the local AGB luminosity function.

astro-ph