arXiv Science⌕ Search

arXiv · 2611.25512

Physics-Guided Multi-Output Surrogate Modeling of a Centralized-UPS Data Center

Abstract

Data centers supplied through centralized uninterruptible power supplies (UPSs) are converter-dominated loads whose grid response reflects IT demand, power-conversion controls, energy storage, cooling, and site-support dynamics. This paper develops and electrically realizes a causal multi-output surrogate for a nominal 1-MW, 0.48-kV simulated data center. Four physics-informed terminal features-normalized IT demand, positive-sequence voltage deviation, voltage-unbalance ratio, and frequency deviation-are used to predict active and reactive power at both the point of common coupling (PCC) and UPS output. Six causal surrogate families are evaluated using separate training, validation, and held-out trajectories. A ridge-regularized low-order nonlinear autoregressive model with exogenous inputs (NARX) achieves the lowest validation and test errors, with mean four-output errors of 0.1959\% and 0.1441\% on a 1-MVA base, respectively. The selected surrogate is then coupled to a three-phase electrical interface in MATLAB/Simulink, where predicted PCC active power controls a variable resistive load and predicted reactive power is realized through controlled current sources synchronized to the PCC voltage. Across two 41-s AI workload profiles, including an additional pipeline parallelism trajectory, the electrical realization tracks the NARX commands with active- and reactive-power RMSEs of 0.604 kW and 0.353 kVAR for Evaluation Profile A and 1.539 kW and 0.442 kVAR for Evaluation Profile B, respectively. The results demonstrate a compact terminal surrogate that can reproduce both predicted power trajectories and their corresponding three-phase electrical behavior under measured PCC excitation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jesus D. Vasquez-Plaza, Sunil Subedi, Jin Dong, Joao Pereira Pinto. 2026-11-19. Physics-Guided Multi-Output Surrogate Modeling of a Centralized-UPS Data Center. https://arxiv.science/abs/2611.25512

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

The Cesàro Value Iteration

In this paper, we consider undiscouted infinite-horizon optimal control for deterministic systems with an uncountable state and input space. We specifically address the case when the classic value iteration does not converge. For such systems, we use the Ces`aro mean to define the infinite-horizon optimal control problem and the corresponding infinite-horizon value function. Moreover, for this value function, we introduce the Cesàro value iteration and prove its convergence for the special case of systems with periodic optimal operating behavior. For this instance, we also show that the Cesàro value function recovers the undiscounted infinite-horizon optimal cost, if the latter is well-defined.

eess.SY↗

Comfort energy management system for electrified buildings using hydrogen for seasonal storage

Flexible loads and integrated energy storage in electrified buildings can align volatile renewable energy use with consumption. While battery energy storage systems provide short-term flexibility, hydrogen storage enables seasonal energy shifting. However, since hydrogen systems are expensive, coupling a fuel cell with a heat pump can reduce the required size of the hydrogen system and, therefore, investment costs. To fully exploit the flexibility of this integrated energy system, advanced control strategies are needed. This study proposes a comfort-oriented and grid-aware energy management system for an electrified building equipped with photovoltaics, a battery energy storage system, a hydrogen system, a heat pump, and domestic hot water storage. A novel fuzzy logic-based controller coordinates fuel cell and heat pump operation while exploiting building thermal mass as a flexibility resource. The proposed approach bridges the gap between simple rule-based control and model predictive control, enabling adaptive operation without system models, weather and demand forecasts, or high computational effort. The controller is evaluated over twelve winter weeks for a German single-family household and benchmarked against a rule-based controller and an ideal-forecast model predictive controller. Results show improved thermal comfort and lower electricity costs compared to the rule-based controller. Compared to model predictive control, the proposed controller reduces fuel cell operating hours and toggling counts, leading to more practical system operation. Overall, the proposed controller achieves a favorable trade-off between control performance and implementation complexity, combining low information requirements with improved comfort, storage use, and coordinated fuel cell-heat pump operation.

eess.SY↗

A Heuristic for Scheduling Autonomous Vehicles at Intersections

We consider the coordination of autonomous vehicles at unsignalized intersections, where trajectory planning and crossing-order decisions are intrinsically coupled, thereby making their simultaneous optimization intractable in practice. To this end, we propose a heuristic based on a hierarchical structure consisting of a series of nonlinear programs (NLP) in the lower level, which optimizes trajectories of each vehicle for a given crossing order, and a high-level heuristic to design new crossing schedules that exploits sensitivity information from the lower-level NLPs. Extensive numerical simulations across a broad range of traffic scenarios demonstrate that our strategy achieves substantially improved scheduling with respect to first-in-first-out ordering while preserving computational tractability.

eess.SY↗