arXiv Science⌕ Search

arXiv · 2611.25471

A four-level executable validation protocol for evaluating LLM-generated topology specifications of physics-based HVAC digital twins

Abstract

Physics-based digital twins of air conditioning, a principal energy consumer in manufacturing and buildings, can be generated automatically from a declarative specification of its equipment, connections, and sizing. Large language models (LLMs) now write such specifications from plain-language descriptions. Evaluations of these specifications stop at parse success, completed runs, or textual similarity, and cannot reject a model that converges in simulation but is physically wrong. In this study, a four-level protocol is proposed that tests whether an LLM-written specification not only executes but also yields a physically valid digital twin. Each specification is executed through static validity, model build, simulation convergence, and behavioral equivalence with a hidden reference model within bands calibrated by $\pm$20% sizing perturbations. The protocol was applied to eight LLMs and fourteen HVAC topologies, five describing an existing low-humidity test chamber. To test for authorship bias, engineers and a second model family also described six topologies. Within three repairs, seven of eight models built in 98.6 to 100% of trials, with simulations converging in at least 80.0%, but reached behavioral equivalence in only 50.0 to 98.6%. About half of the failed trials converged, but not to the reference steady state, mostly in desiccant rotor systems. Pooled pass rates varied by under five percentage points across description authors. These results imply that the physics hardest to model in each field, here the desiccant rotor, must enter the generation framework as validation levels. The protocol can be adapted to other fields that generate executable digital twins from declarative specifications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Younghwan Joo, Jeonghoon Han, Sanghyun Oh, Soosik Bang, Sung-il Kim. 2026-11-19. A four-level executable validation protocol for evaluating LLM-generated topology specifications of physics-based HVAC digital twins. https://arxiv.science/abs/2611.25471

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

The Cesàro Value Iteration

In this paper, we consider undiscouted infinite-horizon optimal control for deterministic systems with an uncountable state and input space. We specifically address the case when the classic value iteration does not converge. For such systems, we use the Ces`aro mean to define the infinite-horizon optimal control problem and the corresponding infinite-horizon value function. Moreover, for this value function, we introduce the Cesàro value iteration and prove its convergence for the special case of systems with periodic optimal operating behavior. For this instance, we also show that the Cesàro value function recovers the undiscounted infinite-horizon optimal cost, if the latter is well-defined.

eess.SY↗

Comfort energy management system for electrified buildings using hydrogen for seasonal storage

Flexible loads and integrated energy storage in electrified buildings can align volatile renewable energy use with consumption. While battery energy storage systems provide short-term flexibility, hydrogen storage enables seasonal energy shifting. However, since hydrogen systems are expensive, coupling a fuel cell with a heat pump can reduce the required size of the hydrogen system and, therefore, investment costs. To fully exploit the flexibility of this integrated energy system, advanced control strategies are needed. This study proposes a comfort-oriented and grid-aware energy management system for an electrified building equipped with photovoltaics, a battery energy storage system, a hydrogen system, a heat pump, and domestic hot water storage. A novel fuzzy logic-based controller coordinates fuel cell and heat pump operation while exploiting building thermal mass as a flexibility resource. The proposed approach bridges the gap between simple rule-based control and model predictive control, enabling adaptive operation without system models, weather and demand forecasts, or high computational effort. The controller is evaluated over twelve winter weeks for a German single-family household and benchmarked against a rule-based controller and an ideal-forecast model predictive controller. Results show improved thermal comfort and lower electricity costs compared to the rule-based controller. Compared to model predictive control, the proposed controller reduces fuel cell operating hours and toggling counts, leading to more practical system operation. Overall, the proposed controller achieves a favorable trade-off between control performance and implementation complexity, combining low information requirements with improved comfort, storage use, and coordinated fuel cell-heat pump operation.

eess.SY↗

A Heuristic for Scheduling Autonomous Vehicles at Intersections

We consider the coordination of autonomous vehicles at unsignalized intersections, where trajectory planning and crossing-order decisions are intrinsically coupled, thereby making their simultaneous optimization intractable in practice. To this end, we propose a heuristic based on a hierarchical structure consisting of a series of nonlinear programs (NLP) in the lower level, which optimizes trajectories of each vehicle for a given crossing order, and a high-level heuristic to design new crossing schedules that exploits sensitivity information from the lower-level NLPs. Extensive numerical simulations across a broad range of traffic scenarios demonstrate that our strategy achieves substantially improved scheduling with respect to first-in-first-out ordering while preserving computational tractability.

eess.SY↗