arXiv Science⌕ Search

arXiv · 2611.21850

Improved accuracy of the reference photon calibration standards in the network of gravitational-wave observatories during the O4 observing run

Abstract

The global network of gravitational wave observatories uses systems known as Photon Calibrators to provide absolute calibration via laser radiation pressure. Successive detector improvements are increasing sensitivity, enabling not only increase the detection rate but also detections with high signal to noise ratios. To optimally extract information from these detected signals, continual effort is directed at pushing the state of the art of the interferometer calibration accuracy. To improve the accuracy of the locally-maintained laser power standards for photon calibration, a new global calibration scheme was implemented by using transfer standards calibrated at both the National Institute of Standards and Tech- nology (NIST) in the US and the Physikalisch-Technische Bundesanstalt (PTB) in Germany during the recently completed fourth observing run. We report the results of a long-duration NIST-PTB bilateral comparison conducted over almost three years and the results of propagation of transfer standard calibrations to the reference power sensors maintained at each observatory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dripta Bhattacharjee, Cervane Grimaud, Matthew Spidell, Stefan Kück, Dan Chen, Joseph Betzwieser, Shingo Hido, Paul Lagabbe, Holger Lecher, John Lehman, Francisco Llamas, Marco López, Loïc Rolland, Anthony Sanchez, Richard Savage. 2026-11-16. Improved accuracy of the reference photon calibration standards in the network of gravitational-wave observatories during the O4 observing run. https://arxiv.science/abs/2611.21850

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Optimal robust detection statistics for pulsar timing arrays

Pulsar timing arrays (PTAs) seek to detect a nano-Hz stochastic gravitational-wave background (GWB) by searching for the characteristic Hellings and Downs angular pattern of timing residual correlations. So far, the evidence remains below the conventional $5σ$ threshold, as assessed using the literature-standard "optimal cross-correlation detection statistic". While this quadratic combination of cross-correlated data maximizes the deflection (signal-to-noise ratio), it does not maximize the detection probability at fixed false-alarm probability (FAP), and therefore is not Neyman-Pearson (NP) optimal for the assumed noise and signal models. The NP-optimal detection statistic is a different quadratic form, but is not used because it also incorporates autocorrelations, making it more susceptible to uncertainties in the modeling of pulsar timing noise. Here, we derive the best compromise: a quadratic detection statistic which is as close as possible to the NP-optimal detection statistic (minimizing the variance of its difference with the NP statistic) subject to the constraint that it only uses cross-correlations, so that it is less affected by pulsar noise modeling errors. We study the performance of this new NPMV statistic for a simulated PTA whose noise and (putative) signal match those of the NANOGrav 15-year data release: GWB amplitude $A_{\rm gw} = 2.1 \times 10^{-15}$ and spectral index $γ= 13/3$. Compared to the literature-standard "optimal" cross-correlation detection statistic, the NPMV statistic increases the detection probability by 47% when operating at a $5σ$ false-alarm probability of $α= 2.9 \times 10^{-7}$.

astro-ph.IM↗

Lunar Reflective Interferometry

We present the method of lunar reflection interferometry (LRI) in which a virtual interferometer can be formed by using a spacecraft-borne antenna in lunar orbit that receives both direct rays and those reflected from the lunar surface. The technique exploits the method of images and is akin to the classic "sea cliff" interferometer, with the Moon's surface, primarily the lunar Maria, replacing the ocean surface. We describe the method in detail, demonstrate that significant portions of the Moon's surface are sufficiently smooth at low radio frequencies, $ν\lesssim 10\,\mathrm{MHz}$, for the technique to work, and outline a spacecraft instrument implementation. We describe potential systematic errors and how they could be mitigated. We present several astrophysics applications of the method.

astro-ph.IM↗

Wideband overlapped polyphase channelizer for kinetic inductance detector readout: split-path architecture and experimental characterization

Frequency-multiplexed readout of kinetic inductance detector arrays measures the complex transmission of thousands of superconducting resonators. The channelizer that separates them introduces systematic effects: a gain that depends on where each tone falls in the channel grid, leakage between channels and added noise. This article presents a 4096-channel polyphase channelizer with 2/1 overlap for a 4.096 GS/s input, implemented on a first-generation radio-frequency system-on-chip, and a procedure to characterize it on the board with two receive chains, one digitizing the excitation as a reference. A split-path architecture computes the two overlap states in parallel filter branches at 256 MHz and reorders them frame by frame, under three control rules; it keeps only the transform stage at 512 MHz and affords a prototype of 16 taps per polyphase path (65536 coefficients) at the multiplication rate of a published 8-tap bank. Each selected channel is exported as a complex series at 1 MS/s. The measured channel response follows the coefficient-table model within 0.15 dB down to -28 dB, with both overlapping channels at full gain across their common band. Leakage into every measured channel 1.875 MHz or more from the tone is -94 dBc or lower, apart from images attributed to converter interleaving. The signal-to-noise ratio per sample lies within 1.7 dB of the limit set by the data-sheet noise density of the converter, and an emulated detector pulse is recovered with a decay time of 14.65 $μ$s (standard uncertainty 0.04 $μ$s), within 0.7% of the expected value.

astro-ph.IM↗