Scintillator-Based Event-Mode Neutron Imaging with Timepix4 Readout

Abstract

Scintillator-based event-mode neutron imaging is emerging as a powerful approach to neutron radiography. Unlike conventional integrating-mode neutron imaging, which accumulates scintillation light during an exposure, event reconstruction estimates neutron-event positions and arrival times from time-stamped optical responses. We investigated this approach using a self-developed Timepix4-based optical readout system, image-formation analysis, and beam experiments at the China Spallation Neutron Source under different scintillator and optical configurations. The analysis explains how event localization can reduce image blur associated with the spatial extent of individual scintillation responses. Under the same 0.35$\times$ optical configuration, event reconstruction improved the spatial resolution from 164.2 to 91.9 $μ$m at 10% modulation transfer function (MTF), while a 2.1$\times$ configuration with a $\mathrm{Gd_2O_2S:Tb}$ scintillator achieved 26.1 $μ$m at the same MTF threshold. Following event reconstruction and rejection of single-photon reconstructed events, the mean peak-normalized spectral response in the 6-8 angstrom out-of-band interval decreased by 85.4% relative to the raw-pixel wavelength-count spectrum, indicating reduced afterglow-related spectral background. Under the tested pulsed-beam conditions, the maximum instantaneous pixel-hit rate per pixel was approximately four times its time-averaged value, providing an experimental basis for assessing readout requirements at higher neutron flux. Conventional radiography resolved structural details, while energy-selective imaging enhanced the contrast between materials with similar broadband transmission and Bragg-edge imaging revealed crystallographic features in steel. These results demonstrate the imaging-quality benefits and capabilities of scintillator-based event-mode neutron imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wenqin Yang, Xingfen Jiang, Junan Geng, Yang Liu, Qicai Li, Hongbin Liu, Xiaojuan Zhou, Yanfeng Wang, Li Yu, Xiuku Wang, Peixun Shen, Jiayi Ren, Yubin Zhao, Jianrong Zhou, Zhijia Sun, Yuanbo Chen. 2026-11-16. Scintillator-Based Event-Mode Neutron Imaging with Timepix4 Readout. https://arxiv.science/abs/2611.20750

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Improved Pion-Kaon Identification in Heavy-Ion Collisions with a Two-Dimensional Transformation

Accurate identification of charged pions and kaons is essential for precision measurements in relativistic heavy-ion collisions, but becomes increasingly challenging at intermediate and high transverse momentum because of the increasing overlap of the TPC and TOF particle identification responses. In this work, we quantitatively benchmark a two-dimensional shift-and-rotation PID procedure that combines the $nσ_π$ and mass-squared $(m^{2})$ information. The benchmark is performed using Au+Au collision events generated with the AMPT model, where the detector response is modeled using $p_{T}$-dependent PID parameters extracted from STAR data. Since the true particle identities and input yields are known in AMPT but are not used during the reconstruction, the procedure can be evaluated through a direct closure test that is not possible with experimental data alone. The two-dimensional procedure is compared with a reference one-dimensional method consisting of an $|nσ_π|<$ 3 preselection followed by a Gaussian fit to the $m^{2}$ distribution. While both methods perform well when pion and kaon PID responses are well separated, the two-dimensional procedure provides improved yield closure as the PID distributions increasingly overlap at high $p_{T}$. The reconstructed-to-input yield ratio remains within 2\% of unity up to $p_T =$ 3 GeV/$c$, whereas the reference one-dimensional procedure shows a larger deviation. Reaction-plane $v_{2}$ closure tests show that both the reference one-dimensional and two-dimensional PID procedures reproduce the AMPT input $v_{2}$ within the statistical uncertainties over the studied $p_{T}$ range. These results demonstrate that the two-dimensional procedure substantially improves the high-$p_{T}$ yield reconstruction without introducing a detectable bias in the extracted $v_{2}$ under the STAR-like detector response considered here.

physics.ins-det↗

Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings

Optical coatings with minimal thermal noise are essential for high-precision, laser-based metrology experiments. Substrate-transferred crystalline GaAs/Al$_{0.92}$Ga$_{0.08}$As coatings have the lowest thermal noise for high-reflectivity mirror coatings with $λ=900$ nm -- 12 $μ$m. Time-frequency stabilization experiments have demonstrated that GaAs/AlGaAs mirror coatings have a lower noise floor than amorphous mirror coatings. These mirrors are now being developed at sizes $\ge 300$ mm for gravitational-wave detectors. In order to understand the coating's fundamental loss mechanisms, which cause thermal noise, we have performed the first measurement of the mechanical loss at cryogenic temperatures using a cryogenic, multimodal, gentle nodal suspension system, which operates from 12 K to room temperature. This initial measurement used a silicon substrate whose asymmetry produced excess friction with the nodal support. Accounting for this friction and Akhiezer loss in the substrate and coating, the mechanical loss agrees well with the thermal noise observed in experiments using cryogenic fixed-cavities with GaAs/AlGaAs mirrors.

physics.ins-det↗

Rotating Capacitive System for Measurement of a Third Order Gravity Gradient Based on a Single-Axis Mechanical Oscillator. Part I, Theory

This paper is a feasibility study on a single-axis mechanical oscillator, mounted on a miniature circular rotating platform, that is proposed to be used for measuring a quantity proportional to the second vertical derivative of gravitational acceleration projected onto the oscillator's sensitivity axis. The latter is aligned with the axis of rotation. Part I establishes theoretical feasibility only. Design constraints, quantitative sensitivity, error budgets, and mobile platform performance will be addressed in Part II.

physics.ins-det↗