arXiv Science⌕ Search

arXiv · 2611.20226

Streaming across viewing conditions - The effect of viewing distance and display luminance on video quality

Abstract

The visibility of streamed video distortions is affected by the user's display and viewing conditions, such as their display's luminance or the viewing distance. Distortions become less visible at lower luminance levels or farther viewing distances. However, most image and video quality metrics assume fixed optimal display and viewing conditions, making them insensitive to the viewing conditions. In this work, we demonstrate how existing metrics can be adapted to account for both factors and compare such an adaptation with the metrics that natively model viewing conditions. First, we collected a new video quality dataset, HDR-VDC, which contains streaming distortions in 4K HDR videos. The dataset consists of 12 4K and 4 FHD HDR source video content, each distorted with AV1 encoding and Lanczos upscaling from a lower resolution. The quality loss due to the distortions was measured at two viewing distances, corresponding to 60 and 120 pixels per visual degree, and two display mean luminance levels, varying by a factor of 8 in terms of luminance. Next, we developed a pre-processing framework that lets us adapt many quality metrics so that they can evaluate content across the viewing distances and luminance levels. The framework employs a display model and perceptually uniform encoding, PU21, to account for the effect of display luminance, and perspective projection scaling (PPS) to account for the effect of viewing distance. We used the framework to compare the performance of 35 state-of-the-art metrics. This allowed us to identify a selection of existing quality metrics that can be effectively adapted to account for the viewing conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dounia Hammou, Lukáš Krasula, Christos G. Bampis, Zhi Li, Rafał K. Mantiuk. 2026-11-15. Streaming across viewing conditions - The effect of viewing distance and display luminance on video quality. https://arxiv.science/abs/2611.20226

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Physics-Aware Zero-Shot Learning for Low-Dose CT from a Single Sinogram

Low-dose computed tomography (CT) imaging remains a persistent challenge, especially under heterogeneous acquisition conditions. Zero-shot learning, which enables models to learn directly from individual images without external supervision, represents a compelling approach to mitigate distribution mismatches arising from variations in scanner hardware, imaging protocols, and patient demographics. However, most existing zero-shot approaches employ down-sampling operations that reduce spatial resolution and cause domain shifts, which become particularly evident when applied to raw sinogram data. Here, we propose a physics-aware zero-shot CT denoising framework to exploit the conjugate symmetry property intrinsic to CT sinograms. Conjugate X-ray pencil beams traverse identical anatomical paths and ideally yield the same expected attenuation values but with independent noise realizations. By randomly mapping sinogram values between conjugate-ray pairs, we synthesize structurally consistent yet noise-diverse sinogram pairs, enabling self-supervised network training without external data. The resulting lightweight denoising network demonstrates strong generalization across low-dose simulation, clinical helical CT, and preclinical photon-counting CT datasets. Quantitative and qualitative results demonstrate competitive denoising performance, with favorable noise suppression and structural preservation across diverse acquisition settings. This work establishes a generalizable and data-efficient paradigm for CT denoising that integrates physical redundancy into learning-based image reconstruction. The code for the proposed method is openly available at: https://github.com/shiyongyi/Physics-Aware-Zero-Shot-CT-Sinogram-Denoising

eess.IV↗

QUTCC: Quantile Uncertainty Training and Conformal Calibration for Imaging Inverse Problems

While deep learning offers tremendous promise for scientific and medical imaging, any failures and hallucinations (predictions that do not coincide with reality) are hard to pinpoint and can have serious downstream consequences. Uncertainty estimation techniques, such as conformal prediction, can help by predicting statistically valid error bars for a model's prediction. However, popular conformal prediction methods were not designed for high-dimensional image-valued problems and do not take into account spatial correlations within an image during conformal calibration, resulting in larger-than-necessary uncertainty intervals. We propose a practical simultaneous quantile regression method that enables non-linear, spatially-adaptive scaling during conformal calibration. Our method, QUTCC uses a U-Net architecture with a quantile embedding to learn a full conditional quantile distribution during training, and then leverages this non-linear, learned function for spatially-adaptive conformal calibration. At test time, our method can efficiently estimate uncertainty intervals with pixel-marginal coverage guarantees. In addition, QUTCC can also predict pixel-wise conditional probability density estimates without any built-in distributional assumptions. We evaluate our method on several denoising problems, accelerated magnetic resonance imaging, and quantitative phase microscopy. Our method consistently produces tighter uncertainty intervals than prior conformal methods at the same coverage level, can predict plausible conditional distributions for different tasks, and in some cases, high-uncertainty regions can help us locate hallucinations in a model's prediction.

eess.IV↗

GroundGazer: An optical reference system for planar localization with millimeter accuracy at low cost

Highly accurate indoor localization systems with absolute mm positioning accuracy are currently expensive. They include laser trackers, total stations, and motion capture systems relying on multiple high-end cameras. In this work, we introduce a high-accuracy, planar indoor localization system named GroundGazer (GG) for autonomous mobile robots (AMRs). GG estimates the AMR's planar position with mm and its heading with sub-degree accuracy. The system requires only a monocular (fisheye) camera, a chessboard floor, and an optional laser diode. Our system is simple and low-cost due to the chessboard floor, robust, scalable to multiple robots, and extendable to 3D position and orientation estimation.

eess.IV↗