arXiv Science⌕ Search

arXiv · 2611.17348

Topology-based fast neutron background suppression and sterile-neutrino sensitivity in a segmented reactor ${\overlineν}_{e}$ detector

Abstract

Reactor electron antineutrinos are commonly detected through the inverse beta decay interaction, with a prompt positron followed by delayed neutron capture. In shallow or above-ground segmented organic scintillator detectors, correlated fast neutrons are a dominant background because proton recoils can mimic the prompt IBD signal. We study topology-based machine learning using the Indian Scintillator Matrix for Reactor Anti-Neutrinos detector as a case study. A multilayer perceptron is trained on reconstructed topological observables from detailed Geant4 simulations. The $\mathrm{F_{1}}$ score and bootstrap resampling on an independent validation sample yield a fixed threshold of $P{\mathrm{IBD}}>0.40$. Applied without further optimization to an independent testing sample, the MLP retains $\mathrm{(83.4\pm 0.7)\%}$ of IBD events and rejects $\mathrm{(77.3\pm 0.7)\%}$ of fast neutron events. In a controlled spectral benchmark using an independent AmBe fast neutron spectrum, the selection reduces the net candidate-spectrum deformation by $\mathrm{84\%}$. The energy dependent signal acceptance and residual fast neutron component are subsequently incorporated into a binned likelihood, which recovers the injected IBD signal strength as $\mathrm{\hatα=0.993^{+0.053}_{-0.048}}$, with an empirical goodness-of-fit probability of $0.434$. The expected sterile-neutrino sensitivity for the ISMRAN detector is evaluated at baselines of 13 m and 18 m, with two years of exposure at each baseline. For the nominal pre-MLP $S/B=1:2$ benchmark and the background model, retaining the classifier score in a joint ($\mathrm{E_{prompt}\times P_{IBD}}$) likelihood improves the 95\% C.L. sensitivity to $\sin^{2}2θ_{14}$ by a logarithmically averaged 7.9\% over $0.1\leqΔm_{41}^{2}\leq1~\mathrm{eV}^{2}$ relative to an energy-only likelihood with the same fast neutron contamination.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roni Dey. 2026-10-05. Topology-based fast neutron background suppression and sterile-neutrino sensitivity in a segmented reactor ${\overlineν}_{e}$ detector. https://arxiv.science/abs/2611.17348

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Improved Pion-Kaon Identification in Heavy-Ion Collisions with a Two-Dimensional Transformation

Accurate identification of charged pions and kaons is essential for precision measurements in relativistic heavy-ion collisions, but becomes increasingly challenging at intermediate and high transverse momentum because of the increasing overlap of the TPC and TOF particle identification responses. In this work, we quantitatively benchmark a two-dimensional shift-and-rotation PID procedure that combines the $nσ_π$ and mass-squared $(m^{2})$ information. The benchmark is performed using Au+Au collision events generated with the AMPT model, where the detector response is modeled using $p_{T}$-dependent PID parameters extracted from STAR data. Since the true particle identities and input yields are known in AMPT but are not used during the reconstruction, the procedure can be evaluated through a direct closure test that is not possible with experimental data alone. The two-dimensional procedure is compared with a reference one-dimensional method consisting of an $|nσ_π|<$ 3 preselection followed by a Gaussian fit to the $m^{2}$ distribution. While both methods perform well when pion and kaon PID responses are well separated, the two-dimensional procedure provides improved yield closure as the PID distributions increasingly overlap at high $p_{T}$. The reconstructed-to-input yield ratio remains within 2\% of unity up to $p_T =$ 3 GeV/$c$, whereas the reference one-dimensional procedure shows a larger deviation. Reaction-plane $v_{2}$ closure tests show that both the reference one-dimensional and two-dimensional PID procedures reproduce the AMPT input $v_{2}$ within the statistical uncertainties over the studied $p_{T}$ range. These results demonstrate that the two-dimensional procedure substantially improves the high-$p_{T}$ yield reconstruction without introducing a detectable bias in the extracted $v_{2}$ under the STAR-like detector response considered here.

physics.ins-det↗

Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings

Optical coatings with minimal thermal noise are essential for high-precision, laser-based metrology experiments. Substrate-transferred crystalline GaAs/Al$_{0.92}$Ga$_{0.08}$As coatings have the lowest thermal noise for high-reflectivity mirror coatings with $λ=900$ nm -- 12 $μ$m. Time-frequency stabilization experiments have demonstrated that GaAs/AlGaAs mirror coatings have a lower noise floor than amorphous mirror coatings. These mirrors are now being developed at sizes $\ge 300$ mm for gravitational-wave detectors. In order to understand the coating's fundamental loss mechanisms, which cause thermal noise, we have performed the first measurement of the mechanical loss at cryogenic temperatures using a cryogenic, multimodal, gentle nodal suspension system, which operates from 12 K to room temperature. This initial measurement used a silicon substrate whose asymmetry produced excess friction with the nodal support. Accounting for this friction and Akhiezer loss in the substrate and coating, the mechanical loss agrees well with the thermal noise observed in experiments using cryogenic fixed-cavities with GaAs/AlGaAs mirrors.

physics.ins-det↗

Rotating Capacitive System for Measurement of a Third Order Gravity Gradient Based on a Single-Axis Mechanical Oscillator. Part I, Theory

This paper is a feasibility study on a single-axis mechanical oscillator, mounted on a miniature circular rotating platform, that is proposed to be used for measuring a quantity proportional to the second vertical derivative of gravitational acceleration projected onto the oscillator's sensitivity axis. The latter is aligned with the axis of rotation. Part I establishes theoretical feasibility only. Design constraints, quantitative sensitivity, error budgets, and mobile platform performance will be addressed in Part II.

physics.ins-det↗