arXiv Science⌕ Search

arXiv · 2611.14395

Improved Myelin Water Fraction Estimation and Uncertainty Mapping in Multicomponent T2 Relaxometry via NNLS Bootstrap Aggregation

Abstract

Estimating the myelin water fraction (MWF) from multicomponent T2 relaxometry requires solving an ill-conditioned inverse problem, making estimates sensitive to noise. Regularization can improve stability but may introduce bias. Conventional NNLS-based methods also provide point estimates without directly quantifying voxelwise variability. To address these limitations, we propose the non-negative least squares Bootstrap Barycenter (NNLS-BB), combining residual resampling with repeated NNLS reconstruction. We average spectra and derived parameters across bootstrap replicates and use their standard deviations to characterize sensitivity to signal perturbations. The method requires neither an explicit spectral regularization penalty nor a training dataset. NNLS-BB was evaluated on 40,000 simulated voxels with signal-to-noise ratios of 50-1000, against conventional NNLS, two regularized NNLS methods, and a model-informed machine-learning (MIML) method. Scan-rescan repeatability was assessed across 20 white-matter regions in two independent cohorts comprising 13 healthy participants. NNLS-BB achieved the lowest MWF mean absolute error and root mean squared error in all simulated noise regimes. Mean absolute error decreased by 36-41% relative to conventional NNLS, alongside lower error dispersion. Compared with Bayes-Reg-$D^{-1}$ and MIML, NNLS-BB achieved comparable dispersion but substantially lower bias, although MIML reconstructed the full spectrum more accurately. In vivo, NNLS-BB yielded the lowest regional scan-rescan dispersion and highest mean correlation in both cohorts. Bootstrap standard-deviation maps provided complementary information about parameter variability. These results support residual-bootstrap aggregation for improving MWF estimation while providing voxelwise variability maps from a single acquisition.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Erick J Canales-Rodríguez, Thomas Yu, Juan Manuel Górriz, Santiago Galdo-Álvarez, Tobias Kober, Tom Hilbert, Gian Franco Piredda, Miguel Ángel Rivas-Fernández. 2026-11-10. Improved Myelin Water Fraction Estimation and Uncertainty Mapping in Multicomponent T2 Relaxometry via NNLS Bootstrap Aggregation. https://arxiv.science/abs/2611.14395

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Deep Learning-based Multiparametric Quantitative Ultrasound for Hepatic Steatosis Assessment

Quantitative ultrasound (QUS) has shown promise for liver fat quantification in metabolic dysfunction-associated fatty liver disease (MAFLD). Incorporating multiple parameters has demonstrated the potential to outperform single QUS parameter measures. Here, we propose a deep learning-based multiparametric QUS framework that learns effective integration of multiple features from QUS measures to estimate pixel-wise hepatic fat fraction, enabling the detecting of heterogeneous fat accumulation within the liver. We developed a U-Net based network architecture to predict local fat fraction percentages, which takes 2D QUS maps as input and is trained with magnetic resonance imaging-proton density fat fraction (MRI-PDFF) as the ground truth. We extracted 2D QUS maps (H-scan frequency, at-tenuation, Nakagami, and RF/envelope/log-compressed data) and tested various input configura-tions consisting of different combinations of the QUS parameters. We enrolled 30 patients with healthy livers or suspected/confirmed MASLD, and acquired ultrasound RF data, and validated our approach using the patient data. Among all tested input configurations, the model combining H-scan, attenuation, and Nak-agami parameters achieved the best performance, with a Spearman correlation coefficient (Rs) of 0.92 and an area under the curve (AUC) of 0.98. The predicted fat fraction maps exhibited color changes concordant with the gradual increasing in MRI-PDFF, from normal liver to 45% fat ac-cumulation. These findings demonstrate that deep learning can integrate multiparametric QUS in-formation in a fully data-driven manner, providing a localized fat fraction map rather than a single whole-liver value. We anticipate that our deep learning framework can offer potential advantages for future assessment of heterogeneous disease development in liver for more complex, progres-sive liver diseases such as steatohepatitis.

physics.med-ph↗

BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction

To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation arranged as channels, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated using a conditional GAN with a SwinUNETR generator and a PatchGAN discriminator. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.

physics.med-ph↗

Dynamic infrared thermography and computed tomography angiography fusion for DIEP flap perforator selection: a novel measurement system

Accurate perforator selection is critical for successful deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. While computed tomography angiography (CTA) provides high-resolution anatomical detail, it lacks functional perfusion assessment. Dynamic infrared thermography (DIRT), in contrast, captures superficial rewarming dynamics but lacks objective anatomical validation. This study presents a standardized multimodal measurement system enabling automated fusion of DIRT with CTA-derived perforator coordinates. The framework integrates controlled thermographic acquisition, real-time hotspot detection, metric spatial calibration, and global one-to-one assignment of thermal hotspots to CTA perforators within a predefined periumbilical region of interest. The workflow was evaluated in 12 patients. Of 46 CTA perforators within the region of interest, 84.8% were successfully linked to thermographic hotspots, with a median spatial offset of 14.74 mm. Automated assignment excluded 76.1% of detected hotspots due to lack of anatomical correspondence, thereby reducing subjective interpretation. The proposed system enables quantitative multimodal validation of functional and anatomical imaging and provides objective support for perforator selection in clinical practice.

physics.med-ph↗