arXiv Science⌕ Search

arXiv · 2611.14179

Quantum-Enhanced QSAR for DYRK1A: Evaluating Complementary and Utility QPU-Derived Molecular Representations

Abstract

In drug discovery, hit identification selects a limited set of compounds for experimental evaluation from a larger collection of candidates. Because laboratory screening capacity is limited, that choice determines which chemical series continue into further investigation. A hit that is not assayed does not enter confirmation or the analog series, and that chemical series is not opened. For the DYRK1A kinase, the same test molecules were scored from a tabular representation of molecular descriptors and from a vector measured on a quantum processor, with the same RBF-SVM. The question is whether the two models propose the same set for experimental evaluation: they propose different compounds. The model on the vector measured on the quantum processor includes compounds that the tabular representation leaves out, and among them are already-labeled actives. The tabular representation includes actives that the vector measured on the quantum processor leaves out. What is reported is that set: who enters, with what label, and whether published chemistry already mentions it. No formal quantum advantage is claimed, nor a mechanism for why the two vectors separate differently. Those compounds fall within the neighborhood that both representations already cover; what changes is which model marks them active. From that follows the cost of predictive disagreement: each model would send a different chemical series to experimental evaluation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alejandro Giraldo, Daniel Ruiz, Mariano Caruso, Hamed Mohammadbagherpoor, Vladyslav Bohun. 2026-11-10. Quantum-Enhanced QSAR for DYRK1A: Evaluating Complementary and Utility QPU-Derived Molecular Representations. https://arxiv.science/abs/2611.14179

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

A Diamond Quantum Oscilloscope

Quantum-enhanced metrology has achieved remarkable precision in parameter estimation, but extending these advantages to continuous time-dependent fields (waveform sensing) remains a formidable challenge due to the infinite-dimensional nature of the signal. Here, we report the first experimental realization of a room-temperature solid-state quantum oscilloscope based on a sequential quantum difference amplification strategy. Within a zero-order-hold reconstruction framework, our method completely bypasses the need for massive entanglement. Crucially, we demonstrate that the overall waveform reconstruction error unequivocally follows the theoretically predicted Heisenberg scaling of \(O(N^{-1/2})\), decisively surpassing the classical \(O(N^{-1/3})\) limit. This transformative precision requires approximately 30-fold fewer quantum resources than conventional methods to achieve the same waveform error. Furthermore, we demonstrate the reconstruction of a multicomponent waveform and distinctly resolve weak high-frequency components that are entirely drowned in the shot noise of classical sampling. These results transition quantum metrology from parameter estimation into a practical instrument, establishing a genuine quantum advantage in continuous waveform reconstruction and paving the way for critical applications such as nanoscale nuclear magnetic resonance imaging, where detecting extremely weak signals is crucial for resolving molecular structures.

quant-ph↗

Information geometry and entanglement under phase-space deformation through nonsymplectic congruence transformation

We investigate the relationship between Fisher-Rao (FR) information geometry and Gaussian quantum correlations under nonsymplectic phase-space transformations, with particular emphasis on noncommutative (NC) deformation implemented through the Bopp shift. Using the established affine invariance of the FR-metric, we examine the transformation properties of Gaussian covariance matrices and the positive partial transpose (PPT) criterion under invertible congruence transformations. For a bipartite Gaussian system, we demonstrate that keeping the canonical partial-transpose (PT) matrix fixed in the deformed phase space produces deformation-dependent spectral shifts that may cross the conventional PPT threshold. When the PT operation is transported together with the covariance and commutation matrices, the physical PPT spectrum and separability classification remain invariant under local Darboux transformations. We further investigate a two-dimensional anisotropic oscillator in NC phase space, where the deformation parameters modify the effective canonical Hamiltonian and consequently influence the Gaussian ground-state correlations and entanglement between canonical modes. The corresponding FR-geometry reveals that the original covariance manifold possesses constant negative scalar curvature. In contrast, the pure symmetric normal-form covariance family is intrinsically one-dimensional and flat. These results distinguish the statistical geometry of Gaussian covariance matrices from the physical quantum correlations determined by the Hamiltonian, commutation structure, and subsystem decomposition.

quant-ph↗

Entanglement preservation and Clauser-Horne nonlocality in electromagnetically induced transparency quantum memories

Understanding how decoherence-induced loss affects entanglement and nonlocal correlations in quantum memories is important for quantum information science. Here we develop a quantitative description of photonic quantum states retrieved from electromagnetically induced transparency (EIT) memories in a ground-state-decoherence-limited regime. Using the dark-state-polariton formalism, we derive the attenuation factor of the retrieved probe mode from the EIT dynamics. This attenuation depends on the coupling field and ground-state coherence decay and is not introduced as an independent phenomenological loss parameter. Within a specified quantum-limited pure-loss model, we use this attenuation to obtain the reduced photonic density operator. We show that, in the symmetric case, the complete retrieved state of an initially path-entangled single photon remains entangled for any nonzero storage efficiency, despite acquiring a vacuum component. In contrast, violation of the unconditional Clauser-Horne inequality under displaced on/off detection without post-selection requires an intrinsic efficiency above 89.7%. We further derive the retrieved N-qubit photonic density operator for multiple independently operating EIT memories. These results establish a quantitative connection between EIT memory dynamics, retrieved quantum states, and operational nonlocality benchmarks under explicit channel assumptions.

quant-ph↗