arXiv Science⌕ Search

arXiv · 2611.11258

Auto-GlaKG: Automated Biomarker Reasoning for Explainable Glaucoma Detection

Abstract

Interpretable glaucoma detection requires a transparent connection between fundus images, clinically meaningful biomarkers, and diagnostic predictions. Knowledge graph (KG) reasoning provides this structure, but performance measured using annotated biomarkers does not establish performance when only images are available. We present Auto-GlaKG, an automated framework that combines image-based biomarker prediction with fixed clinical-prior rules. A ResNet50 network predicts the cup-to-disc ratio (CDR) and six morphological signs using biomarker supervision, and a KG reasoner aggregates their signed rule contributions into a glaucoma score. On 689 fundus images evaluated using stratified, group-aware five-fold cross-validation, Auto-GlaKG achieves a pooled area under the receiver operating characteristic curve (AUC) of 0.951 (95\% confidence interval: 0.931--0.969), with sensitivity of 0.970 and specificity of 0.779. The matched image classifier also achieves an AUC of 0.951, while the rule stage adds 0.2~ms per image. Replacing predicted CDR with its annotation increases fold-mean AUC from 0.953 to 0.995. The framework provides an explicit rule-level account of image-based predictions and identifies CDR estimation as a priority for validation using independently measured biomarkers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cheng Huang, Zeyu Han, Yian Hu, Yaopeng Ding, Jingxi Qiu, Yadi Liu. 2026-11-08. Auto-GlaKG: Automated Biomarker Reasoning for Explainable Glaucoma Detection. https://arxiv.science/abs/2611.11258

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

RTime-QA: A Benchmark for Atomic Temporal Event Understanding in Multimodal Large Language Models

Multimodal large language models (MLLMs) perform well on video benchmarks, yet many video questions can be answered from a single frame or from language priors, which leaves open whether these models perceive how an event unfolds in time. We introduce \rtqa, a benchmark for atomic temporal event understanding built on time-reversed question pairs: each video is accompanied by its reversal, and each question is asked on both videos with identical text and options but different correct answers, so that a deterministic model that ignores the order of the frames cannot answer both. \rtqa{} comprises 8,420 questions of five types on 1,278 videos, 639 videos and their reversals. The questions are derived from event annotations that a proposer model writes, a reviewer model checks and human annotators verify, and three subsets target fast evaluation (\rtqatiny), questions that are hard to answer from the first and last frames (\rtqacore) and two consecutive events (\rtqacomp). All 20 evaluated models are less accurate on reversed videos. On \rtqafull, proprietary models answer both questions of 90.6--94.4\% of the pairs and the strongest open-source model of 66.8\%; on \rtqacore, the proprietary models drop to 55.6--64.5\%, and shuffling the frames reduces the paired accuracy of the tested open-source models to 3.4--7.4\%. We further build \rtqatrain{} with the same pipeline, without human verification, and train three open-source MLLMs on it with supervised fine-tuning (SFT) and reinforcement learning (DAPO) under matched settings: both raise paired accuracy on \rtqafull, SFT by 20.7--27.4 points and DAPO by 5.9--22.9 points. For Qwen3.5-9B-Thinking, the training data also help on two other temporal benchmarks: SFT and DAPO raise the Vinoground text score by 5.8 and 3.8 points, respectively, and DAPO raises the TVBench macro accuracy by 4.6 points.

cs.CV↗

Morphology-driven single-domain generalization for cross-cohort Alzheimer's disease detection using 3D MRIs

Although Alzheimer's disease detection via MRIs has advanced significantly thanks to contemporary deep learning models, challenges such as class imbalance, protocol variations, and limited dataset diversity often hinder their generalization capacity. To address this issue, this article focuses on the single domain generalization setting, where given the data of one domain, a model is designed and developed with maximal performance w.r.t. an unseen domain of distinct distribution. Since brain morphology is known to play a crucial role in Alzheimer's diagnosis, we propose the use of learnable pseudo-morphological modules aimed at producing shape-aware, anatomically meaningful class-specific augmentations in combination with a supervised contrastive learning module to extract robust class-specific representations. Experiments conducted across three datasets show improved performance and generalization capacity, especially under class imbalance and imaging protocol variations. The source code will be made available upon acceptance at https://github.com/zobia111/SDG-Alzheimer.

cs.CV↗

Evaluating and Mitigating Skin Color Bias in Skin Lesion Classificatio

Skin lesion classifiers may overlook performance disparity because of subtle skin tone variations by treating skin tone as a categorical attribute. This study proposes a method that represents skin tone as a continuous attribute and assigns individual weights to each sample based on its nonlinear relationship with classification performance. Evaluations on two dermatological datasets showed that fairness metrics were sensitive to skin-color categorization. The proposed method also demonstrated more stable fairness improvements than conventional categorical reweighting while generally preserving classification performance.

cs.CV↗