arXiv Science⌕ Search

arXiv · 2611.10626

EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning

Abstract

Endoscopic diagnosis unfolds over native video, where a single positive finding during traversal of the gastrointestinal tract sets off a multi-minute chain of reasoning over location, morphology, severity and intervention. Existing endoscopy multimodal benchmarks test only static images or single-disease videos, which miss the temporal and clinical reasoning that real-world reporting demands. We introduce EndoSCOP-V, a video-grounded multi-turn evaluation framework for structured endoscopy reporting and clinical reasoning. It contains 1,307 real-world endoscopy and colonoscopy videos (63.2 h; 97% 1080p) averaging about 174 s. Its 20,274 question-answer turns are instantiated deterministically from clinician-filled structured endoscopy-reporting EHRs, so no per-case annotation is synthetic or LLM-rephrased. They come from 1,033 clinician-reviewed templates, about 18 per disease, that span a clinically aligned 9-task x 30-sub-task reporting taxonomy over 54 World Endoscopy Organization (WEO) MST 3.0 diseases. 22% of procedures carry co-existing pathologies, up to six per case. A Markovian context-pruned oracle-forcing protocol evaluates the dialogue turn by turn, injecting the gold answer before each subsequent turn so that per-turn reasoning is isolated from cascading dialogue errors. A panel of 15 board-certified endoscopists sets a 78% strict-accuracy baseline on 1,500 questions. Across 14 open-weight LMMs, the best 27B-class model reaches 59.8% strict accuracy, falling to 53.4% once format-trivial disease-rejection items are excluded. On a between-subjects spot-check, the best of 3 frontier proprietary models trails the clinician panel by 23 pp on strict NDR accuracy. Sub-task analysis reveals consistent gaps in quantitative measurement, multi-variable grading and intervention reasoning on long-horizon video. Data: Hugging Face (EndoSCOP-V). Code: GitHub (abhi25t/EndoSCOP-V).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Abhishek Tyagi, Tanmay Jain, Vilas Biradar, Krithi Krishna Koduri, Misba Hul Bashir Masoodi, Swetha Rapolu, Hardik Rughwani, Rachana Kotha, Anjan Kumar Kaipa, Anudeep Katrevula, Rakesh Garlapati, Aniruddha Pratap Singh, Rajendra Patel, Abhay Tyagi, Sundeep Lakhtakia, Mohan Ramchandani, Rakesh Kalapala, D. Nageshwar Reddy. 2026-11-07. EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning. https://arxiv.science/abs/2611.10626

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

RTime-QA: A Benchmark for Atomic Temporal Event Understanding in Multimodal Large Language Models

Multimodal large language models (MLLMs) perform well on video benchmarks, yet many video questions can be answered from a single frame or from language priors, which leaves open whether these models perceive how an event unfolds in time. We introduce \rtqa, a benchmark for atomic temporal event understanding built on time-reversed question pairs: each video is accompanied by its reversal, and each question is asked on both videos with identical text and options but different correct answers, so that a deterministic model that ignores the order of the frames cannot answer both. \rtqa{} comprises 8,420 questions of five types on 1,278 videos, 639 videos and their reversals. The questions are derived from event annotations that a proposer model writes, a reviewer model checks and human annotators verify, and three subsets target fast evaluation (\rtqatiny), questions that are hard to answer from the first and last frames (\rtqacore) and two consecutive events (\rtqacomp). All 20 evaluated models are less accurate on reversed videos. On \rtqafull, proprietary models answer both questions of 90.6--94.4\% of the pairs and the strongest open-source model of 66.8\%; on \rtqacore, the proprietary models drop to 55.6--64.5\%, and shuffling the frames reduces the paired accuracy of the tested open-source models to 3.4--7.4\%. We further build \rtqatrain{} with the same pipeline, without human verification, and train three open-source MLLMs on it with supervised fine-tuning (SFT) and reinforcement learning (DAPO) under matched settings: both raise paired accuracy on \rtqafull, SFT by 20.7--27.4 points and DAPO by 5.9--22.9 points. For Qwen3.5-9B-Thinking, the training data also help on two other temporal benchmarks: SFT and DAPO raise the Vinoground text score by 5.8 and 3.8 points, respectively, and DAPO raises the TVBench macro accuracy by 4.6 points.

cs.CV↗

Morphology-driven single-domain generalization for cross-cohort Alzheimer's disease detection using 3D MRIs

Although Alzheimer's disease detection via MRIs has advanced significantly thanks to contemporary deep learning models, challenges such as class imbalance, protocol variations, and limited dataset diversity often hinder their generalization capacity. To address this issue, this article focuses on the single domain generalization setting, where given the data of one domain, a model is designed and developed with maximal performance w.r.t. an unseen domain of distinct distribution. Since brain morphology is known to play a crucial role in Alzheimer's diagnosis, we propose the use of learnable pseudo-morphological modules aimed at producing shape-aware, anatomically meaningful class-specific augmentations in combination with a supervised contrastive learning module to extract robust class-specific representations. Experiments conducted across three datasets show improved performance and generalization capacity, especially under class imbalance and imaging protocol variations. The source code will be made available upon acceptance at https://github.com/zobia111/SDG-Alzheimer.

cs.CV↗

Evaluating and Mitigating Skin Color Bias in Skin Lesion Classificatio

Skin lesion classifiers may overlook performance disparity because of subtle skin tone variations by treating skin tone as a categorical attribute. This study proposes a method that represents skin tone as a continuous attribute and assigns individual weights to each sample based on its nonlinear relationship with classification performance. Evaluations on two dermatological datasets showed that fairness metrics were sensitive to skin-color categorization. The proposed method also demonstrated more stable fairness improvements than conventional categorical reweighting while generally preserving classification performance.

cs.CV↗