arXiv Science⌕ Search

arXiv · 2611.05959

Local information processing capacity: anatomy of computation in neuromorphic systems

Abstract

Many neuromorphic systems possess rich internal computational structures shaped by their physical dynamics. However, existing metrics characterize only global computation, leaving these local structures unresolved despite their importance for system interpretation, optimization and miniaturization. Here, we introduce local information processing capacity (L-IPC), which represents individual dynamical states as vectors in an infinite-dimensional Hilbert space and decomposes their computational properties through subspace projections onto nonlinearity orders and memory steps, with the residual quantifying computational irrelevance. Applied to three systems with comparable global capacities (an echo state network, an ion-gating reservoir and a spin-wave reservoir), L-IPC reveals markedly different distributions of computation, ranging from homogeneous to spatially, temporally and spectrally structured patterns. These local profiles further guide task-specific pruning, outperforming standard approaches at the same size in the structured systems. These results establish L-IPC as a general framework for anatomizing computation and guiding task-adaptive design in neuromorphic systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jiaxuan Chen, Daiki Nishioka, Yicheng Song, Ryo Iguchi, Sota Hikasa, Hina Kitano, Akira Hirose, Takashi Tsuchiya. 2026-11-04. Local information processing capacity: anatomy of computation in neuromorphic systems. https://arxiv.org/abs/2611.05959

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Metamaterial tactile displays with programmable virtual pixels

Tactile displays present information by supplying localized mechanical signals across their surface, but conventional approaches often require an actuator to be positioned at every location where feedback is provided, limiting resolution and increasing complexity. Wave-mediated tactile displays exploit wave transmission to generate virtual pixels using far fewer actuators, but are constrained in resolution by the intrinsic dispersion characteristics of the display medium. Here, we show how this constraint can be overcome by applying metamaterial physics to engineer wave transmission in a rigid plate using an optimized lattice of resonators. The resulting system exhibits a slow-wave dispersion branch that reduces the wavelengths available for constructing virtual pixels, thereby enhancing display resolution by an order of magnitude. We demonstrate a metamaterial tactile display driven by eight peripheral actuators that is capable of generating localized virtual tactile pixels at any surface location with centimeter-scale resolution. The location, timing, and waveform of each pixel can be specified computationally, and the output bandwidth, 75-400 Hz, spans a substantial portion of the tactile frequency range. In four perceptual experiments, participants localized, explored, and discriminated multi-pixel patterns comprising transient and sustained vibrations with accuracies ranging from 95.3% to 100%. This research provides metamaterial engineering methods that enable the design of tactile displays driven by few actuated degrees of freedom, with implications for many future application areas.

cs.ET↗

NN-Based FeFET Compact Modeling for SPICE Simulation

Prototyping and early-stage circuit evaluation for emerging transistor technologies require fast and accurate compact models for SPICE simulations. Standard physics-based compact models, such as BSIM, offer high fidelity but demand extensive domain expertise and time-consuming equation formulation for every new physical effect, significantly slowing technology development. Neural network (NN)-based models offer a scalable alternative approach, but they rely heavily on smooth numerical solver data with explicit high-order derivative information. However, measurement data suffers from complex noise patterns, making derivative extraction challenging and complicating NN-based transistor modeling. This work presents a derivative-free NN training framework employing spectral normalization to naturally smooth derivative behavior and filter measurement noise. Using drain current measurements from a fabricated 28 nm ferroelectric device, we design an NN-based compact model that captures the full spectrum of polarization amplitudes and supports dynamic polarization switching in transient simulations. To demonstrate its capability, we deploy the model in a commercial SPICE software to simulate write and read operations for large-scale memory arrays with up to 512x512 size, including parasitic effects. Our approach bridges raw measurements with NN-based SPICE-compatible transistor modeling, significantly reducing model development time and enabling rapid circuit-level prototyping for emerging devices.

cs.ET↗

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

cs.ET↗